Skip to main content

Download Center

Search by product Model Number

By Document Type

3GPP Signal Analyzer Measurement Guide

This Measurement Guide documents 3GPP signal analysis for the following Anritsu instruments: BTS Master, Cell Master, Spectrum Master, and LMR Master. P/N: 10580-00234

Measurement Guide pdf 19.9 MB Version: AE 1/16/2020

3GPP2 Signal Analyzer Measurement Guide

This Measurement Guide documents 3GPP2 signal analysis for the BTS Master, Cell Master, and Spectrum Master. P/N: 10580-00235

Measurement Guide pdf 3.4 MB Version: F 1/16/2020

WiMAX Signal Analyzer for Anritsu RF and Microwave Handheld Instruments

This Measurement Guide documents WiMAX signal analysis for the BTS Master, Cell Master, LMR Master, and the Spectrum Master. P/N: 10580-00236

Measurement Guide pdf 9.9 MB Version: F 1/16/2020

Spectrum Master MS2723B and MS2724B Maintenance Manual

This manual provides maintenance instructions for Anritsu Spectrum Master Models MS2723B and MS2724B. It provides a list of recommended test equipment, performance verification procedures, parts replacement procedures, and a replaceable parts list.

Maintenance Manual pdf 4.7 MB Version: F 12/1/2017

Spectrum Analyzer Measurement Guide

This Measurement Guide documents spectrum analysis, interference analysis, channel scanner function, Zero-Span IF Output, Gated Sweep, IQ Waveform Capture, Coverage Mapping, and AM/FM/PM analysis for Anritsu handheld instruments. P/N: 10580-00244

Measurement Guide pdf 19.2 MB Version: M 12/18/2014

Spectrum Master MS272xB User Guide

This user guide is specific to the Spectrum Master MS272xB (models MS2721B, MS2723B, and MS2724B) and the Digital Broadcast Field Analyzer MS8911B

User Guide pdf 11.8 MB Version: P 10/3/2012

Spectrum Master MS272xB Help

Help is a compilation of user documentation for easier viewing and navigation. P/N: 10450-00034 | OHS | A | 08/24/2011

Online Help System html 1.5 KB Version: A 8/24/2011

Spectrum Master MS2724B Technical Data Sheet

Anritsu¡¯s high performance handheld spectrum analyzer provides the wireless professional the performance needed for the most demanding measurements in harsh RF and physical environments. Whether it is for spectrum monitoring, broadcast proofing, interference analysis, RF and microwave measurements, regulatory compliance, or Wi-Fi and wireless network measurements, the Spectrum Master is the ideal instrument to making fast and reliable measurements.

Datasheet pdf 1.5 MB Version: R 7/26/2010

Spectrum Master MS272xB Programming Manual

This manual contains descriptions of the remote commands available for the Spectrum Master MS2721B, MS2723B, and MS2724B.

Programming Manual pdf 880.4 KB Version: A 1/19/2007

By Document Type

Updating Legacy Anritsu Handheld Instrument Firmware

This document provides an overview of the firmware update process using Anritsu’s Master Software Tools (MST). For detailed information about Master Software Tools, refer to the Help menu > Help Contents. For detailed information on the firmware update process refer to the User Guide for your Anritsu handheld instrument.

Drivers Software Downloads pdf 383.0 KB Version: C 7/31/2017

Updating Anritsu Handheld Instrument Firmware

This document provides an overview of the firmware update process. For further details, please refer to the user guide for your Anritsu handheld instrument.

Drivers Software Downloads pdf 344.1 KB 10/30/2015

Firmware Update for the Spectrum Master MS2724B

This firmware update contains the latest upgrades for your instrument. Installation instructions are included in the download. If your current instrument firmware is older than v1.30, please update firmware using Anritsu's Master Software Tools instead of this download. If your current instrument firmware is v1.30 or higher, this download is appropriate. Release History

Drivers Software Downloads exe 15.6 MB Version: v1.39 3/28/2011

By Product Category

How do I get my MS2721B to use a manual ethernet address after I enter one?

After you enter the ethernet address you want to use (i.e. 10.0.0.2) you must restart the unit on a live ethernet connection. You can use the crossover cable to connect to your computer's ethernet port as a live port, but only if you are assigning an address. If you use the DHCP (dynamic host control protocol), you must hook to a live ethernet connection that allows for DHCP requests.

How do I calculate Noise Power density (dBm/Hz) from a measurement made with the MS2711D or MS272x spectrum analyzer?

On the instrument, use a Noise Marker.  If you have a captured trace (in dBm) that you want to convert to dBm/Hz, use the following formula:  dBm/Hz = dBm - 10 * log(1.03 * RBW)

Can I use the C/I (carrier to interference ratio) to make SINAD measurements on a narrow-band FM signal?

No, the C/I measurement is intended for use when measuring Wi-Fi (802.11b,g and a) signals. The measurement makes certain assumptions about the nature of the Wi-Fi signal being measured and how it is affected by various types of interferers.

Can the MS272xB spectrum analyzers do a G/T measurement? We want to determine the ratio between a CW pilot carrier from the satellite and the noise coming from deep space.

To do this measurement first measure the satellite carrier power. Using a marker, capture the peak of the CW signal to get that power level. Then turn the receiving dish a few degrees so it is aimed at deep space and measure the background noise level. We suggest using a fixed reference marker set at the peak of the CW carrier and a delta marker at the same frequency set to be a noise marker. By doing this, the delta marker value is in dB/Hz relative to the CW signal and once the receiving antenna is turned to deep space the answer can be read directly from the delta marker value.

My MS2721B has a fully charged battery. When I unplug it from the AC/DC adapter it still shows the AC/DC icon. Is this normal?

The battery has internal circuitry that communicates with the main board on the Spectrum Master. Either the battery is defective or something in the Spectrum Master is failing to communicate.  Please contact your local service center to have this issue resolved.

How can I get Marker one to be fixed and have the Delta marker be variable on the same frequency?

After you set the MS2721B to the desired center frequency, make sure you don’t have any attenuation set on input port.   Turn Marker one on. Select Peak Search. More Under Marker Style or Fixed Marker turn to fixed or on. Back Turn Delta ON for the marker one.   You can change now the RF input level and will have the Delta value.

Are Anritsu PC applications for downloading files from the Site Master supported on 64 bit Windows OS's?

Currently Anritsu does not but is working diligently to provide a solution.

How do I retrieve channel scanner or interference analyzer data remotely from an MS2724B?

There are no remote programming commands available at this time to automatically retrieve channel scanner or interference analyzer data.  What can be done is to save each set of measurement data onto the instrument's internal memory or a USB memory stick connected to the instrument. The measurement data can then be transferred to a PC using Master Software Tools or directly via the USB memory stick. From within MST you can view or export the saved measurements. If the unit had the GPS option enabled, each exported file will contain the GPS time and location at the time the data was collected along with the measurement data itself.

What methodolgy is used to derive GPS data for the Master products?

The GPS coordinates delivered by the instruments are based on the WGS-84 methodology of determining position.

What are the specs for the adapter 1091-81-R

Max. VSWR  DC – 18 Ghz 1.06 + .005 fGhz Adapter, DC to 18 GHz, 50 Ohm, N(f)-SMA(f)

On W-CDMA Over The Air (OTA) Measurements , where can I find the chip time?

According to the WCDMA standard the chip rate is fixed at 3.84 Mcps, thus chip time can derived to be 0.26 micro seconds.

On WCDMA/HSPDA Over The Air (OTA) Measurements, what is the formula that relates Ec and CPICH?

Ec is defined as the chip energy for PCPICH and is determined by multiplying CPICH by the chip time. Ec = CPICH + 10*log10(Chip Time) or Ec = CPICH - 65.84dB

Are the display data points fixed in the MS2721A Spectrum Analyzer?

Yes, the display data points are fixed and are independent of the Frequency Span and Resolution Bandwidth. There are 551 display points when the instrument is in the normal screen display. By selecting the Trace Fullscreen (On) feature the display point count increases to 661.

I would like to know about the memory profile of MS2724B Spectrum Analyzer.

The MS2724B has 256 MB of Flash non-volatile memory, two 32kB EEPROM chips, and 64 MB DRAM volatile memory. The instrument is supplied with an external 64 MB Compact Flash module that is plugged into a socket on the top of the board. It does not have a hard drive or any other type of volatile or non-volatile memory.

Is it possible to set more than 5 segmented limit lines on MS2711D?

No, it is not possible to set more than 5 segmented limit lines on the MS2711D however we have other Handheld Spectrum Analyzers in which a limit line can consist of up to 40 segments. The model numbers are MS2721B, MS2723B, and MS2724B.

What is the memory (Internal Flash Memory and EEPROM) clearing procedure for MS2724B Spectrum Master?

To erase all the user information that is stored in Internal Flash Memory and EEPROM, a master reset needs to be done on the instrument. Below is the master reset procedure.: 1. Turn the MS2724B. 2. Press the Shift button then the 8/System button. 3. Press the System Options soft key. 4. Press the Reset soft key. 5. Press the Master Reset soft key. 6. A dialog box will be displayed on the instruments screen warning that all settings will be returned to factory default values and all user files will be deleted. 7. Press the ENTER button to complete the master reset. 8. After several seconds (which can grow to several minutes if there are a very large number of measurements saved in the instrument) the instrument will reboot.

Can I enter the sweep time manually in Spectrum Analyzer mode?

Yes you can. You can go into the sweep menu (MT8222A, MS272XB) or "MEAS/DISP" menu (MS2711D, S332D, S312D, MT8212B) and select "Min Sweep Time" and enter the desired sweep time. If you enter a time that is faster than what the instrument is capable of then the instrument will change the sweep speed and default to whatever the instrument can do. For every measurement point, the instrument spends a certain time and if it is too fast, then it is measured again. This is why the actual sweep time is usually a little bit longer than the requested time. In zero span mode, the sweep times are exact.

What detection methods are available on MS2721B Spectrum Master?

The available detection methods are Peak, RMS, Negative, Sample and Quasi-peak.

What kind of reference oscillator is used in the MS2721B Spectrum Master?

An oven controlled crystal oscillator (OCXO) is the reference oscillator that is used in the MS2721B.

Do we still need to buy Option 19 to use the MA24106A with the instrument?

Yes - you need Option 19 to use the MA24106A sensor with the Spectrum Master, VNA Master, BTS Master, and Economy Spectrum Analyzer (MS271xB). The software that is included with the purchase of the MA24106A is used to connect the sensor to a PC.