Photonics–Electronics Convergence is a Game-Changing Key Technology

Growing global demand for data centers is increasing total power consumption rapidly. Reducing power consumption by data centers is a challenge. Anritsu interviewed Dr. Shu Namiki, Derector of Platform Photonics Research Center, AIST, about the activities of the GDC Council and photonics–electronics convergence technology as a key to reducing power consumption.

White Paper pdf 2.2 MB 01/06/2023

New Radio RF Conformance Test System ME7873NR

The New Radio RF Conformance Test System ME7873NR is a RF Conformance Test (RFCT) platform for RF transmitter / receiver characteristics, performance requirements, and RRM testing of 5G mobile devices compliant with 3GPP standards. Based on the solid and trusted achievements selected and used by customers around the world in the 3G (W-CDMA) and 4G (LTE) era, we will continue to release timely test cases for 5G.

Brochure pdf 2.2 MB 30/05/2023

All-in-One Test Environment for EU eCall Certification and Next-Generation eCall Function Tests

The MD8475B not only simulates a cellular network, but can also simulate changes in the various communications conditions and faults assumed to occur when updating dynamic maps while driving due to combination with other radio environments. In addition, a TCU evaluation environment can be configured easily by connection to a live Cloud server via the Internet connection port.

Leaflet pdf 698.1 KB 24/05/2023

LMR Master S412E User Guide

The LMR Master User Guide is part of a set of manuals that cover all of the instrument functions and their use. This manual covers the instrument overview, system functions, and other common features, along with a brief guide to basic measurement concepts and setups. P/N: 10580-00318

User Guide pdf 13.2 MB Version: AC 24/05/2023

Land Mobile Radio Analyzer and Coverage Measurement Measurement Guide

This Measurement Guide documents Land Mobile Radio signal analysis functions of the Anritsu LMR Master handheld instrument. Anritsu currently supports measurement of Narrowband FM Analog and digital transmitter Land Mobile Radio technologies. P/N: 10580-00243

Measurement Guide pdf 22.2 MB Version: AH 24/05/2023

LMR Master S412E Technical Data Sheet

The S412E offers a solution for installing and maintaining public safety systems. The S412E combines a high performance receiver and spectrum analyzer in a handheld vector network analyzer plus a powerful vector signal generator with internally adjustable power from 0 dBm to –130 dBm. P/N: 11410-00486

Datasheet pdf 7.0 MB Version: AW 24/05/2023

LMR Master S412E Programming Manual

This SCPI Programming Manual provides information for remote operation of the S412E LMR Master using commands sent from an external controller through the Ethernet or USB connection. P/N: 10580-00319

Programming Manual pdf 4.7 MB Version: AC 24/05/2023

VNA Master MS20xxB User Guide

This guide provides information about frequency range, available options, additional documents, general overview, preventive maintenance, and annual verification requirements for the Handheld MS2024B, MS2025B, MS2034B, and MS2035B VNA Master models. P/N: 10580-00301

User Guide pdf 9.2 MB Version: N 23/05/2023

VNA Master MS2036C Product Brochure

The VNA Master specifically addresses complex cable, waveguide and antenna measurement needs in the field with accurate, vector corrected 2-port magnitude, phase, and Time or Distance Domain measurements. P/N: 11410-00544

Brochure pdf 13.1 MB Version: P 19/05/2023

Spectrum Master MS2720T User Guide

System overview and basic operating instructions for the Anritsu Spectrum Master Model MS2720T RF and Microwave Handheld Instruments. P/N: 10580-00340

User Guide pdf 11.7 MB Version: P 19/05/2023

LTE/5G Networks QoS Latency, Jitter, Throughput, and Packet Loss

This simple solution from Anritsu, uses the Network Master to accurately measure the Up-Link and Down-Link Latencies, simultaneously, with time between two testers synchronised by GPS.

Leaflet pdf 3.7 MB 19/05/2023

MS9740B Optical Spectrum Analyzer SCPI Remote Control Operation Manual

The remote control function sends commands via the communications interface from the remote control PC to set the measuring instrument and read the measurement results and measuring instrument conditions.

Operations Manual pdf 2.3 MB Version: v3.0 18/05/2023

MS9740B Optical Spectrum Analyzer Remote Control Operation Manual

The remote control function sends commands via the communications interface from the remote control PC to set the measuring instrument and read the measurement results and measuring instrument conditions.

Operations Manual pdf 2.3 MB Version: v3.0 18/05/2023

MS9740B-009 Multimode fiber interface (50/62.5 μm) Operation Manual

The MS9740B-009 is a modified option of the MS9740B.

Operations Manual pdf 221.0 KB Version: v2.0 18/05/2023

MS9740B Optical Spectrum Analyzer Operation Manual

The MS9740B Optical Spectrum Analyzer measures the power distribution (spectrum) of optical wavelengths.

Operations Manual pdf 5.7 MB Version: v6.0 18/05/2023

Optical Spectrum Analyzer MS9740B

The Optical Spectrum Analyzer MS9740B is an all-in-one optical spectrum analyzer for SM and MM fiber. The MS9740B reduces the total time from waveform sweeping to data transfer to external control equipment and supports simple analysis procedures, offering excellent cost performance and better productivity.

Brochure pdf 5.0 MB 15/05/2023

Optical Pulse Output Spectrum Measurement Solution - Facilitates Stable Production of High-Power LDs

Anritsu has developed a optical pulse measurement option for its MS9740B. Installing this option in the MS9740B supports an optical pulse measurement mode that captures the spectrum of optical pulses from the LD asynchronously without trigger signal input in the same measurement time as when measuring a CW optical spectrum.

Leaflet pdf 273.2 KB 15/05/2023

Optical Spectrum Analyzer MS9740B

The Optical Spectrum Analyzer MS9740B is an all-in-one optical spectrum analyzer for SM and MM fiber. The MS9740B reduces the total time from waveform sweeping to data transfer to external control equipment and supports simple analysis procedures, offering excellent cost performance and better productivity.

Product Introduction pdf 1.9 MB 15/05/2023

Vector Signal Generator MG3710E

Data Sheet for the Vector Signal Generator MG3710E

Datasheet pdf 2.0 MB 09/05/2023

MT1000A/MT1100A/MT1040A Remote Scripting Operation Manual

MT1000A/MT1000A/MT1040A remote operation manual.

Operations Manual pdf 4.8 MB Version: 11.0 08/05/2023

By Document Type

Firmware Update for the PIM Master MW82119B

This firmware update contains the latest upgrades for your PIM Master MW82119B. Once downloaded, run the file on your computer to see the installation instructions.

Drivers, Software Downloads exe 27.8 MB Version: 4.60 30/05/2023

Firmware Revision History for MW82119B

Firmware release history for the MW82119B PIM Master, Battery Operated, Passive Intermodulation Analyzer.

Drivers, Software Downloads pdf 337.1 KB Version: 4.60 30/05/2023

Firmware Update for the LMR Master S412E

This firmware update contains the latest upgrades for your instrument. Installation instructions are included in the download.

Drivers, Software Downloads exe 50.3 MB Version: 4.60 24/05/2023

LMR Master S412E Firmware Release History

Firmware release history for the LMR Master S412E.

Drivers, Software Downloads pdf 337.1 KB Version: 4.60 24/05/2023

Firmware Release History for the MS202xB and MS203xB

Firmware release history for the VNA Master MS2024B, MS2025B, MS2034B, and MS2035B Vector Network Analyzers.

Drivers, Software Downloads pdf 337.1 KB Version: 4.60 23/05/2023

Firmware Update for the VNA Master MS202xB

This firmware update contains the latest upgrades for your VNA Master MS2024B and MS2025B Vector Network Analyzer. Once downloaded, run the file on your computer to see the installation instructions.

Drivers, Software Downloads exe 36.5 MB Version: 4.60 23/05/2023

Firmware Update for the VNA Master MS203xB

This firmware update contains the latest upgrades for your VNA Master MS2034B and MS2035B Vector Network Analyzer. Once downloaded, run the file on your computer to see the installation instructions.

Drivers, Software Downloads exe 36.5 MB Version: 4.60 23/05/2023

Firmware Update for the Spectrum Master MS2720T

This firmware update contains the latest upgrades for your instrument. Once downloaded, run the file on your computer to see the installation instructions.

Drivers, Software Downloads exe 42.9 MB Version: 4.60 19/05/2023

Firmware Revision History for the MS2720T

Complete firmware release history for the MS2720T Spectrum Master Handheld Spectrum Analyzer.

Drivers, Software Downloads pdf 337.1 KB Version: 4.60 19/05/2023

MS9740B Software

Firmware and documents for MS9740B are contained in the zip file. MD5 : b3630398db82876cf37fc41b06272c5c

Drivers, Software Downloads zip 19.0 MB Version: v1.01.00 18/05/2023

MT1000A_Software

Software of MT1000A. It supports operation with the following modules. ・ MU100011A 100G Multirate Module ・ MU100010A 10G Multirate Module ・ MU100020A/21A/22A/23A OTDR Module ・ MU100040A/B CPRI RF Module ・ MU100090A High Performance GPS Disciplined Oscillator ・ MU100090B High Performance GNSS Disciplined Oscillator MD5 :86BFFF73C1284358F505DF43006ACF13

Drivers, Software Downloads zip 898.0 MB Version: 12.09 08/05/2023

MT1100A_Software

Software of MT1100A. MD5 : C53E9FE47176C26E5766975D8D65AC7E

Drivers, Software Downloads zip 784.6 MB Version: 12.09 08/05/2023

MT1040A_Software

Software of MT1040A. It supports operation with the following modules. MU104011A 100G Multirate Module MU104014A 400G(QSFP-DD) Multirate module MU104015A 400G(OSFP) Multirate module MU100010A 10G Multirate Module MU100011A 100G Multirate Module MU100020A OTDR Module MU100021A OTDR Module MU100022A OTDR Module MU100023A OTDR Module The file size is large, so download after checking your bandwidth. MD5 : 232D442C6976A935BC690EAF634C947C

Drivers, Software Downloads zip 1.6 GB Version: 12.09 08/05/2023

MX100001A windows control software

MX100001A windows control software. MD5 : A2A12C6BF1389ABAB8F1AA49B49CFBD2

Drivers, Software Downloads zip 78.7 MB Version: 12.09 08/05/2023

Network Master Pro/Flex Release Notes

Release information for the latest version of MT1000A/MT1100A

Drivers, Software Downloads pdf 426.1 KB Version: 12.09 08/05/2023

MX100001A windows control software

MX100001A windows control software. MD5 : A2A12C6BF1389ABAB8F1AA49B49CFBD2

Drivers, Software Downloads zip 78.7 MB Version: 12.09 08/05/2023

Network Master Pro Release Notes

Release information for the latest version of MT1040A.

Drivers, Software Downloads pdf 216.0 KB Version: 12.09 08/05/2023

MX100001A windows control software

MX100001A windows control software. MD5 : A2A12C6BF1389ABAB8F1AA49B49CFBD2

Drivers, Software Downloads zip 78.7 MB Version: 12.09 08/05/2023

[Latest] MX183000A High-Speed Serial Data Test Software

It is an installer to install the MX183000A High-Speed Serial Data Test Software. Installer for the latest version. MD5 : 96183dc88c2b13dd31aa1737a2a8fc6d

Drivers, Software Downloads zip 90.0 MB Version: 9.02.03 24/04/2023

[Latest] Signal Quality Analyzer -R Control Software

It is an installer to install the Signal Quality Analyzer-R Control Software. Installer for the latest version. MD5 : eb1231cbd8f7b27a58d0017ca107c26e

Drivers, Software Downloads zip 378.9 MB Version: 9.02.02 24/04/2023

By Product Category

I keep getting a "No Hardware Found" error when trying to connect my MS46122A. How do I fix this?

The issue occurs when the user tries to connect the MS46122A with Windows 8, 8.1 or 10, an error message may appear that suggests that there is no hardware connected to the controller PC. For MS46122A using Windows 8, 8.1, or 10, please follow this manual driver procedure before installing ShockLine software.

How do I get my MS2721B to use a manual ethernet address after I enter one?

After you enter the ethernet address you want to use (i.e. 10.0.0.2) you must restart the unit on a live ethernet connection. You can use the crossover cable to connect to your computer's ethernet port as a live port, but only if you are assigning an address. If you use the DHCP (dynamic host control protocol), you must hook to a live ethernet connection that allows for DHCP requests.

We have a requirement for 2 CW RF microwave signals to be applied 90 degrees out of phase with each other into either end of a device under test. How can this be achieved?

This can be achieved with a pair of MG369XB's with the low band option (either option 4 or 5) and the Phase Tracking Special, SM5815.  With this special the phase difference between the synthesizers can be set either from the front panel or programmed over GPIB. 

The MA2474D specifies a "rise time" of 4 us at 0 dBm room temperature but gives no definition. Can you define it?

Rise time is defined as, the time interval necessary for the power sensor to rise from 10% to 90% of the reading when the signal rises instantaneously from zero (no power) to 1 mW (0 dBm).

What are the differences between the 37000C and 37000D? Should I upgrade?

The decision to upgrade, of course, depends on what you hope to gain through the upgrade. One of the main differences is that the 37000D series supports LAN communication, whereas the 37000C does not. The 37000D has better system dynamic range than the 37000C The 37000D has new measurements not available on the 37000C: Mixer Measurements:  Directly measure frequency translation devices utilizing the NxN multiple device solution utility. The NxN application provides an accurate method of measuring frequency translated devices, such as mixers, providing both magnitude and phase information and the unique ability to measure absolute phase (group) delay. By measuring the response characteristics of device pairs, the Lightning VNA will solve for device pairs and de-embed the characteristics. The NxN application module for mixer measurements includes capabilities for characterizing the IF path of frequency translation device measurements. The result is a real-time display of the de-embedding characteristics of the device under test. Embedding/De-embedding:  Manipulate S2P networks to automatically remove fixtures and devices or add effects of a known structure. De-embedding is generally used for removal of test fixture contributions and other S2P networks from measurements. The de-embedding can be applied to a calibration and then stored for future measurements. Similarly, the Embedding function can be used to simulate matching circuits for optimizing amplifier designs or simply adding effects of a known structure to a measurement.

I am using the Tripp Lite USB to serial adapter. I have verified the adapter is installed properly and the adapter shows up on Com 4 on my PC under Ports (Com & LPT). The port setting is port 4 in HHST. I have all baud rates set correctly and I still get an error in serial communications after several seconds.

If you have a wireless device enabled on your PC or laptop this can interrupt the serial communication.  Go to Network connections and verify your Wireless Network connection type LAN or high speed internet is disabled.  Even it says disconnected you should disabled it.  This has been known to help in cases where everything is set up properly.  Wireless devices such as Palm Pilots can cause this also so disable all wireless devices that you use.

I am using a VISTA 64 bit operating system and Delorme USB to serial adapter and I cannot get HHST to work.

HHST is compatible with VISTA 32 bit operating systems but not with VISTA 64 bit OS.  Also per Delorme their USB to serial adapter is not compatible with VISTA 32 or 64.

When testing with an MT8852B Bluetooth tester, can I perform continuous transmitter tests on un-packetized data?

Yes, you can, by using the "CW measurement" mode. Press the Config hardkey. Then use the arrow keys to select MT8852B, then press Sel. Use the arrow keys to select CW Measurement, then press Sel. This puts the unit into continuous measurement mode. From here you need to select the modulation type and the channel number that the DUT is transmitting on. When everything is set up, press Enter to start measurements. Measurements of power, frequency and modulation are made continuously.

What is the RF loss on the adapter 34VKF50?

The typical insertion loss is 0.5dB per adapter.

Can the date and time be set on the S235A?

The operation of setting date and time is not available for this model

What is the GPS receiver for on a S810D or S820D?

The built-in GPS provides location information (latitude, longitude, altitude) and Universal Time (UT) information. The Site Master can stamp each trace with location information.

Will the S332E CW sig gen option generate a CW signal without the sig gen kit?

Yes it will. The output will be an unleveled signal and the level will be dependent on the battery voltage.

What is the part number for the MA24106A calXpert software?

CalXpert software is part number 2300-528

Why am I seeing an error on voltage when I power up my S820A that I am charging with a 40-168-R charger?

It is OK to use this charger to charge the battery but when testing remove the AC/DC supply so the error will go away. The correct power supply for the S820A is part number 40-115.

Can you tell me the difference between the 2000-767-R and the 2000-1618-R?

The only difference is the frequency range. The 2000-767 is DC to 4 GHz and the 2000-1618-R is DC to 6 GHz. There is also a female 7/16 Open/Short/Load part number 2000-768-R and 2000-1619-R. 2000-768-R frequency range is DC to 4GHz and 2000-1619-R is DC to 6GHz. Related Products: 2000-1618-r, osl-series

In the MS272xB frequency menu there is a soft key labeled "Channel --". What is it used for?

The channel value is used in conjunction with a signal standard such as CDMA to easily tune to a particular channel number associated with that channel. The user doesn't need to know the frequency of a particular channel, just the channel number for a particular air interface standard.

I saved my measurements as a JPEG and a .DAT file. How do I view them on my S332E?

Currently the instrument is only able to create these files, not view them.  However, you can see some text information in the instrument through the “Copy or Delete” functionality such as the title accompanied with the extension (.JPG or .DAT).   JPEGs will have to be opened on your computer. DAT files can be opened with Line Sweep Tools or Hand Held Software Tools.    

Does the MD1260A support GbE and 10GbE mapping inside of an OTU4 signal?

Yes, with options -002, -005, -006, and -007, you can map a 1G, 10G, and 100G ethernet frame inside of the OTU4 signal.