Skip to main content

Download Center

Search by product Model Number

By Document Type

Test & Measurement Solutions for Every Layer of the AI Data Center

Comprehensive test and evaluation solutions for every layer of AI data centers, supporting semiconductors through networks from R&D to mass production.

Product Introduction pdf 5.4 MB 08/10/2026

VectorStar MS464xB Series Microwave Vector Network Analyzer Technical Data Sheet

This document provides detailed specifications for the MS4640B series microwave Vector Network Analyzers (VNAs), including all related options, and accessories. P/N: 11410-00611

Datasheet pdf 8.2 MB Version: AU 07/10/2026

VectorStar ME7838D4 Series Technical Data Sheet

This document provides the specifications for the VectorStar. Broadband and mmWave configuration Vector Network Analyzers (VNAs) listed below, including all related options, and accessories. Alternative configurations available on request. P/N: 11410-01099

Datasheet pdf 4.7 MB Version: L 07/10/2026

VectorStar VNA ME7838G Series Technical Data Sheet

Through the use of a novel coaxial-mode interface connector and advanced transceivers, broadband frequency coverage beyond 220 GHz is now possible. The ME7838G allows a continuous, broadband frequency sweep from 70 kHz to 220 GHz without the need to concatenate multiple systems (operational from 40 kHz to 226 GHz). P/N: 11410-01060

Datasheet pdf 4.5 MB Version: N 07/10/2026

VectorStar Vector Network Analyzer ME7838G4

The ME7838G4 allows a continuous, broadband frequency sweep, in a four-port setup, from 70 kHz to 220 GHz without the need to concatenate multiple systems (operational from 40 kHz to 226 GHz). P/N: 11410-01196

Datasheet pdf 4.4 MB Version: K 07/10/2026

ME7838Ax/A4x Technical Data Sheet

This Technical Data Sheet provides the specifications for the VectorStar Broadband System ME7838AX 2-port and ME7838A4X 4-port Vector Network Analyzer. P/N: 11410-02825

Datasheet pdf 8.6 MB Version: H 07/10/2026

ME7838EX/E4X Technical Data Sheet

This Technical Data Sheet provides the specifications for the VectorStar Broadband System ME7838EX 2-port and ME7838E4X 4-port Vector Network Analyzer. P/N: 11410-02827

Datasheet pdf 9.9 MB Version: H 07/10/2026

Land Mobile Radio Analyzer and Coverage Mapping Measurement Guide

This Measurement Guide documents Land Mobile Radio signal analysis functions of the Anritsu LMR Master handheld instrument. Anritsu currently supports measurement of Narrowband FM Analog and digital transmitter Land Mobile Radio technologies. P/N: 10580-00243

Measurement Guide pdf 23.2 MB Version: AL 07/10/2026

VectorStar ME7838D Series Technical Data Sheet

High Performance, Broadband Network Analysis Solutions, ME7838D Series Microwave Vector Network Analyzers Technical Data Sheet. P/N: 11410-00778

Datasheet pdf 6.3 MB Version: W 07/10/2026

Master Software Tools User Guide

Anritsu Master Software Tools is a Microsoft Windows 2000, XP, Vista compatible program for transferring and editing saved measurements, markers, and limit lines to a PC. Master Software Tools will not function on earlier versions of the Microsoft Windows operating system. P/N: 10580-00439

User Guide pdf 10.4 MB Version: D 07/10/2026

Line Sweep Tools User Guide

This user guide goes through the installation, measurement tools, measurement setups and file management of Line Sweep Tools.

User Guide pdf 6.4 MB Version: B 07/10/2026

Site Master S3xxE Maintenance Manual

Maintenance Manual for the Site Master S331E, S332E, S361E and S362E Cable and Antenna Analyzers.

Maintenance Manual pdf 8.8 MB Version: L 07/10/2026

Line Sweep Tools (LST) Help

Help is a compilation of user documentation for easier viewing and navigation. P/N: 10450-00049 | OHS | B | 10/07/2026

Online Help System html 211.7 KB Version: B 07/10/2026

MT1040A Transport Modules Operation Manual

This is the operation manual of the MT1040A Transport.

Operations Manual pdf 29.0 MB Version: 22.0 07/10/2026

MT1000A Transport Modules Operation Manual

This is the operation manual of the MT1000A Transport.

Operations Manual pdf 30.7 MB Version: 36.0 07/10/2026

MT1000A/MT1100A/MT1040A Remote Scripting Operation Manual

MT1000A/MT1000A/MT1040A remote operation manual.

Operations Manual pdf 4.7 MB Version: 20.0 07/10/2026

Vector Network Analysis Product Portfolio

In 1965, Anritsu filed the patent that defined the first modern Vector Network Analyzer (VNA). We are proud to continue that tradition of innovation to the present day—with the world’s first portfolio of VNAs that bring Nonlinear Transmission Line (NLTL) technology to every measurement scenario from on-wafer device characterization to R&D testing to manufacturing and field operations. P/N: 11410-00905

Brochure pdf 10.8 MB Version: P 06/10/2026

EMC Radiated Power Measurement with the ML2439A Power Meter Application Brief

This application brief describes the use of radiated immunity testing to evaluate how well electronic devices maintain normal operation when exposed to RF electromagnetic fields from wireless communications, broadcast transmitters, and other sources of interference. Covering frequencies from 100 MHz to 8 GHz and beyond, this testing helps manufacturers verify product reliability, meet regulatory requirements, and demonstrate compliance with IEC/EN 61000-4-3. P/N: 11410-03005

Application Note pdf 1.4 MB Version: A 23/09/2026

Signal Quality Analyzer-R MP1900A

This explains the MP1900A series specifications.

Datasheet pdf 3.7 MB 11/09/2026

Signal Quality Analyzer-R MP1900A - 32G/64G NRZ/PAM4 Signal Integrity Test Solution

Data center and network traffic volumes are increasing exponentially as mobile networks start upgrading to 5G and ‘Big Data’ applications become popular. As a consequence, physical-layer devices are required to support faster transmission speeds, larger data capacities, and assured signal quality, in turn making signal integrity analysis ever more important. To meet these needs, Anritsu has implemented more accurate signal integrity tests, such as bit error rate (BER) measurements, crosstalk tests, Jitter Tolerance tests, etc., in its MP1900A test solution for 32G/64G NRZ/PAM4.

Brochure pdf 4.0 MB 09/09/2026

By Document Type

MT1000A_Software

Software of MT1000A. It supports operation with the following modules: "MU100011A 100G Multirate Module", "MU100010A 10G Multirate Module", "MU100020A/21A/22A/23A OTDR Module", "MU100040A/B CPRI RF Module", "MU100090A High Performance GPS Disciplined Oscillator", "MU100090B High Performance GNSS Disciplined Oscillator". MD5 :596193d0b462c82f73b26e13dba29f1a

Drivers, Software Downloads zip 912.3 MB Version: 15.09 07/10/2026

MT1040A_Software

Software of MT1040A. It supports operation with the following modules: "MU104011A 100G Multirate Module", "MU104014A 400G(QSFP-DD) Multirate module", "MU104014B 400G(QSFP-DD) Multirate module", "MU104015A 400G(OSFP) Multirate module", "MU100010A 10G Multirate Module", "MU100011A 100G Multirate Module", "MU100020A/21A/22A/23A OTDR Module". The file size is large, so download after checking your bandwidth. MD5 : ea1387b7e7faf06beff4c9563e8a6f75

Drivers, Software Downloads zip 1.6 GB Version: 15.09 07/10/2026

Network Master Pro Release Notes

Release information for the latest version of MT1000A/MT1100A

Drivers, Software Downloads pdf 461.9 KB Version: 15.09 07/10/2026

MX100001A windows control software

MX100001A windows control software. MD5 : c7de3f6897495ae44deb95d824b7fc94

Drivers, Software Downloads zip 84.2 MB Version: 15.09 07/10/2026

Network Master Pro Release Notes

Release information for the latest version of MT1040A.

Drivers, Software Downloads pdf 299.1 KB Version: 15.09 07/10/2026

MX100001A windows control software

MX100001A windows control software. MD5 : c7de3f6897495ae44deb95d824b7fc94

Drivers, Software Downloads zip 84.2 MB Version: 15.09 07/10/2026

EcoSyn Lite Software Bill of Materials (SBOM)

Software Package Data Exchange (SPDX) format of the components, licenses, and copyrights in the software package.

Drivers, Software Downloads zip 2.5 KB Version: v2026.6.x 20/08/2026

EcoSyn Lite Demo Software Bill of Materials (SBOM)

Software Package Data Exchange (SPDX) format of the components, licenses, and copyrights in the software package.

Drivers, Software Downloads zip 1.1 KB Version: V3.x 20/08/2026

MX190000A Signal Quality Analyzer -R Control Software (For MP1900A)

It is an installer to install the MX190000A Signal Quality Analyzer-R Control Software.(For MP1900A) MD5: c75dfcf6cbe086a7d80058b41cbaa096

Drivers, Software Downloads zip 635.7 MB Version: 12.02.01 19/08/2026

MX183000A High-Speed Serial Data Test Software Release Notes

English MX183000A Release Notes.

Drivers, Software Downloads pdf 443.7 KB Version: 61 19/08/2026

MP1900A Signal Quality Analyzer-R Release Notes

English MP1900A Release Notes. Includes contents of MX190000A and MX183000A.

Drivers, Software Downloads pdf 500.7 KB Version: 75 19/08/2026

MX183000A High-Speed Serial Data Test Software

It is an installer to install the MX183000A High-Speed Serial Data Test Software for MP1800A/MP1900A. MD5: d4febb07b23e1b98a3684f392f95f91d

Drivers, Software Downloads zip 118.6 MB Version: 12.02.01 19/08/2026

PCIe CBB Controller Installation Guide

English PCIe CBB Controller Installation Guide

Drivers, Software Downloads pdf 941.2 KB Version: 6 19/08/2026

EcoSyn Lite MG36021A Firmware

This firmware contains the latest updates and features for your instrument. Download the file to a USB storage device, plug the device into the instrument, and update the software from the system information page.

Drivers, Software Downloads exe 23.0 MB Version: 2026.6.1 28/07/2026

Release History for EcoSyn Lite MG36021A

Release history for the EcoSyn Lite Microwave Frequency Synthesizer MG36021A software.

Drivers, Software Downloads pdf 46.0 KB Version: 2026.6.1 28/07/2026

MX210000A BERTWave Software for MP2110A (V7: Latest Version)

This is for Scope Option x2x/x3x/x4x and BERT. MD5 : 84bf3de2f85b730aa353256979787a79

Drivers, Software Downloads zip 131.6 MB Version: 7.07.02 22/07/2026

MX210000A BERTWave Software Release Note

The MX210000A release notes contain the change history and upgrade procedures for the software of MP2110A BERTWave

Drivers, Software Downloads pdf 726.5 KB Version: 55th Edition 22/07/2026

MX210000A BERTWave Software for MP2110A (V8: Latest Version)

This is for Scope Option x8x. MD5 : 24f4d07bcfe8e85a3ed461810ffc200f

Drivers, Software Downloads zip 150.3 MB Version: 8.02.00 22/07/2026

LMR Master S412E Firmware

This firmware update contains the latest upgrades for your instrument. Installation instructions are included in the download.

Drivers, Software Downloads exe 50.4 MB Version: 4.81 12/06/2026

Release History for the LMR Master S412E firmware

Firmware release history for the LMR Master S412E.

Drivers, Software Downloads pdf 330.5 KB Version: 4.81 12/06/2026

By Product Category

I've recently upgraded the firmware on my S331D and now under the DTF, I see an option for Optical. What is that?

The S331D when upgraded to Version 5.23 firmware or later has the internal capability to make Optical Distance To Fault  measurements.  An external Optical Distance to Fault Module is also needed to make the Optical DTF measurement.  This part number is ODTF-1.

Test There is a lot of concern about loss and reflections in the cable run to the antenna. Why don't the radio MFGs just make transmitters with more power?

The FCC regulates how much output power of any given transmitter. Since this is a fixed quantity, the system designers are forced to squeeze out every bit of performance out of the entire system.

We have a requirement for 2 CW RF microwave signals to be applied 90 degrees out of phase with each other into either end of a device under test. How can this be achieved?

This can be achieved with a pair of MG369XB's with the low band option (either option 4 or 5) and the Phase Tracking Special, SM5815.  With this special the phase difference between the synthesizers can be set either from the front panel or programmed over GPIB. 

How do I get my MS2721B to use a manual ethernet address after I enter one?

After you enter the ethernet address you want to use (i.e. 10.0.0.2) you must restart the unit on a live ethernet connection. You can use the crossover cable to connect to your computer's ethernet port as a live port, but only if you are assigning an address. If you use the DHCP (dynamic host control protocol), you must hook to a live ethernet connection that allows for DHCP requests.

The MA2474D specifies a "rise time" of 4 us at 0 dBm room temperature but gives no definition. Can you define it?

Rise time is defined as, the time interval necessary for the power sensor to rise from 10% to 90% of the reading when the signal rises instantaneously from zero (no power) to 1 mW (0 dBm).

What are the differences between the 37000C and 37000D? Should I upgrade?

The decision to upgrade, of course, depends on what you hope to gain through the upgrade. One of the main differences is that the 37000D series supports LAN communication, whereas the 37000C does not. The 37000D has better system dynamic range than the 37000C The 37000D has new measurements not available on the 37000C: Mixer Measurements:  Directly measure frequency translation devices utilizing the NxN multiple device solution utility. The NxN application provides an accurate method of measuring frequency translated devices, such as mixers, providing both magnitude and phase information and the unique ability to measure absolute phase (group) delay. By measuring the response characteristics of device pairs, the Lightning VNA will solve for device pairs and de-embed the characteristics. The NxN application module for mixer measurements includes capabilities for characterizing the IF path of frequency translation device measurements. The result is a real-time display of the de-embedding characteristics of the device under test. Embedding/De-embedding:  Manipulate S2P networks to automatically remove fixtures and devices or add effects of a known structure. De-embedding is generally used for removal of test fixture contributions and other S2P networks from measurements. The de-embedding can be applied to a calibration and then stored for future measurements. Similarly, the Embedding function can be used to simulate matching circuits for optimizing amplifier designs or simply adding effects of a known structure to a measurement.

I am using the Tripp Lite USB to serial adapter. I have verified the adapter is installed properly and the adapter shows up on Com 4 on my PC under Ports (Com & LPT). The port setting is port 4 in HHST. I have all baud rates set correctly and I still get an error in serial communications after several seconds.

If you have a wireless device enabled on your PC or laptop this can interrupt the serial communication.  Go to Network connections and verify your Wireless Network connection type LAN or high speed internet is disabled.  Even it says disconnected you should disabled it.  This has been known to help in cases where everything is set up properly.  Wireless devices such as Palm Pilots can cause this also so disable all wireless devices that you use.

I am using a VISTA 64 bit operating system and Delorme USB to serial adapter and I cannot get HHST to work.

HHST is compatible with VISTA 32 bit operating systems but not with VISTA 64 bit OS.  Also per Delorme their USB to serial adapter is not compatible with VISTA 32 or 64.

On the S251C, can you save the power monitor measurements (option 5) by using the "Save Display" function?

No, the sitemaster "C" models and below will not save any power monitor (option 5) measurements.  You can use this function on the "D" model sitemasters i.e. S311D/S312D, S331D/S332D, S810D/S820D, and MS2711D.

Can I sweep an antenna with a TMAS on the line?

No. The majority of TMAS for cellular antennas will block the RF signal from the Site Master so the sweeping signal will only go as far as the TMAS and not reach the antenna.

Can I sweep antennas close to another RF source?

Yes but you need to be very careful that the RF from another Source is not going to exceed the 20 dBm max on the RF port.  Power in excess of 20 dBm can result in damage to the unit.

Can a .csv file that was converted from a .vna file of a VNA master be converted back to .vna using Master Software Tools?

No. If someone sends you a .csv file MST cannot be used to convert it back to a .vna file to be opened in MST.

How do I calculate Noise Power density (dBm/Hz) from a measurement made with the MS2711D or MS272x spectrum analyzer?

On the instrument, use a Noise Marker.  If you have a captured trace (in dBm) that you want to convert to dBm/Hz, use the following formula:  dBm/Hz = dBm - 10 * log(1.03 * RBW)

Can I use the C/I (carrier to interference ratio) to make SINAD measurements on a narrow-band FM signal?

No, the C/I measurement is intended for use when measuring Wi-Fi (802.11b,g and a) signals. The measurement makes certain assumptions about the nature of the Wi-Fi signal being measured and how it is affected by various types of interferers.

When I turn on Marker Noise, the detector changes to RMS, why is that?

The RMS detector is the best choice for noise measurements as it provides unbiased averaging of the signal.  This gives a stable answer (because of the averaging) and gives the correct answer (because it is "unbiased").  Contrast this to the peak detector, where the answer continually grows over time, and the Sample detector, which provides no averaging

When do I use the Negative (peak) detector?

This is most useful with a zero-span display, when looking for dropouts in a signal.

When do I use the Peak detector?

This is the default detector for most measurements and is good for measuring CW signals, or for when you want to catch a transient.  The peak detector gives a good overall picture of the spectrum but it’s not very good for measuring noise or modulated signals, as the peak of these signals is not well defined.

When do I use the Quasi-peak detector?

The Quasi-peak detector was designed to mimic the response of the human ear to interference and is used for making EMC (Electro-Magnetic Compatibility) measurements.  The sweep time is quite slow when using this detector, so it is generally used only when making EMC measurements.