I need to do a DTF measurement from 1930 MHz to 1945 MHz on my Site Master. When I set F2 to 1945 MHz I get an error message "New Values Invalid".
answer
Your data points needs to be changed to 130 Data points.  At 130 sata points you can have a span of 13 MHz or larger.  At 259 data points the minimum span is 25.9 MHz.  At 517 data points the minimum span is 51.7 MHz. In the DTF parameter screen it shows the maximum span setting in the Resolution parameter.