Skip to main content

Download Center

Search by product Model Number

By Document Type

Radio Communication Analyzer MT8821C

The Radio Communication Analyzer MT8821C platform covers a frequency range of 30 MHz to 3.8 GHz (3.8 GHz to 6.0 GHz). When the dedicated optional measurement software and hardware is installed, the major TX and RX characteristics of LTE/LTE-Advanced (DL 3CA with 2x2 MIMO, UL 2CA, etc...) W-CDMA/HSPA/HSPA Evolution/DC-HSPA/4C-HSDPA, GSM/GPRS/EGPRS, CDMA2000 1X/1xEV-DO Rev. A,and TD-SCDMA/HSPA/HSDPA Evolution terminals can be measured using a single MT8821C unit.

Brochure pdf 2.9 MB 10/23/2017

LTE Measurement

Introduction to LTE measurement using MX882012C/13C (MX882112C/13C) (Call Processing Version) and MX882042C/43C (MX882142C/43C) (Non-Call Processing Version) LTE Measurement software for Radio Communication Analyzer MT8820C/21C.

Application Note pdf 8.1 MB 10/23/2017

Capturing MT8870A IQ Data

This application note explains how to capture IQ data for debugging.

Application Note pdf 1.3 MB 10/18/2017

Spectrum Master MS2760A User Guide

This manual provides general information, as well as installation and operating information for the Anritsu MS2760A Spectrum Master Ultraportable Spectrum Analyzer and Spectrum Master User Interface Software.

User Guide pdf 4.7 MB Version: D 10/18/2017

Spectrum Master MS2760A Technical Data Sheet

The MS2760A is truly pocket sized, but big on performance with class-leading dynamic range, sweep speed, and amplitude accuracy. Its ultraportable size enables direct connect to almost any DUT, eliminating the need for lossy, expensive cables or antennas. The MS2760A is the world's first handheld millimeter-wave spectrum analyzer to provide continuous coverage from 9 kHz up to 110 GHz, positioning it perfectly for growing millimeter-wave applications like 5G, 802.11ad, satellite communications, automotive radar, and more.

Datasheet pdf 1.9 MB Version: E 10/18/2017

5G Fixed Wireless Radio Validation

This Case Study talks about how a major network equipment manufacturer (NEM) used the Anritsu Spectrum Master MS2720T to test the performance of next-generation 28 GHz 5G radios in a coverage mapping exercise.

Case Study pdf 661.1 KB Version: A 10/18/2017

Flexible Test Environment for European eCall Compliance to Application Tests

The MD8475B not only simulates a cellular network, but can also simulate changes in the various communications conditions and faults assumed to occur when updating dynamic maps while driving due to combination with other radio environments. In addition, a TCU evaluation environment can be configured easily by connection to a live Cloud server via the Internet connection port.

Leaflet pdf 472.8 KB 10/18/2017

Flexible Test Environment for European eCall Compliance to Application Tests

Anritsu eCall solution combining Signalling Tester MD8475A and eCall Tester MX703330E offers the flexible test environment for European eCall compliance to application tests, which helps improve IVS quality and reliability.

Leaflet pdf 470.7 KB 10/17/2017

Wireless Connectivity Test Set MT8862A

The Wireless Connectivity Test Set MT8862A is for measuring the RF TRx characteristics of WLAN IEEE802.11 a/b/g/n/ac equipment. It uses standard WLAN protocol messaging in the Network Mode to measure test items, such as Tx power, modulation accuracy (EVM), Rx sensitivity (PER) etc., at connection with the device under test (DUT).

Brochure pdf 1.6 MB 10/16/2017

Wireless Connectivity Test Set MT8862A

The Wireless Connectivity Test Set MT8862A is for measuring the RF TRx characteristics of WLAN IEEE802.11 a/b/g/n/ac equipment. Measure RF performance under actual operating conditions for quality assurance of diverse and complex devices. Ideal for RF measurements at product development and design validation.

Product Introduction pdf 2.6 MB 10/16/2017

MS2760A Spectrum Master Help System

This manual provides general information, as well as installation and operating information for the Anritsu MS2760A Spectrum Master Ultraportable Spectrum Analyzer and Spectrum Master User Interface Software.

Online Help System htm 185.2 KB Version: A 10/16/2017

Spectrum Master MS2720T Programming Manual

Programming instructions for the Anritsu Spectrum Master Model MS2720T RF and Microwave Handheld Spectrum Analyzer.

Programming Manual pdf 3.5 MB Version: F 10/11/2017

Mobile InterferenceHunter User Guide

Mobile InterferenceHunter is a drive tool for locating RF interference sources. Mobile InterferenceHunter is a Microsoft Windows application. It runs on a laptop or tablet computer and can connect to Anritsu handheld spectrum analyzers through an Ethernet cable or Wi-Fi via a travel router. The system displays multiple indicators of power levels which aid in determining the location of the interfering signal source.

User Guide pdf 3.4 MB Version: C 10/11/2017

Spectrum Master MS2720T User Guide

System overview and basic operating instructions for the Anritsu Spectrum Master Model MS2720T RF and Microwave Handheld Instruments.

User Guide pdf 11.8 MB Version: J 10/11/2017

Mobile InterferenceHunter Help

Mobile InterferenceHunter is a drive tool for locating RF interference sources. Mobile InterferenceHunter is a Microsoft Windows application. It runs on a laptop or tablet computer and can connect to Anritsu handheld spectrum analyzers through an Ethernet cable or Wi-Fi via a travel router. The system displays multiple indicators of power levels which aid in determining the location of the interfering signal source.

This helpset details the initial setup of the hardware, software, and interfaces to the instrument and its RF connections. Display Layout describes the software user interface and features. How To describes how to perform specific tasks within the Mobile InterferenceHunter software.

Online Help System htm 185.0 KB Version: A 10/11/2017

3GPP Signal Analyzer Measurement Guide

This Measurement Guide documents 3GPP signal analysis for the following Anritsu instruments: BTS Master, Cell Master, Spectrum Master, and LMR Master.

Measurement Guide pdf 20.1 MB Version: Y 10/11/2017

Spectrum Master MS2720T Technical Data Sheet

The MS2720T represents the highest performance handheld spectrum analyzers available in the world as Anritsu pushes the envelope closer to benchtop quality. This generation introduces a touch screen, full-band tracking generators to 20 GHz, and best-in-class performance for dynamic range, DANL, phase noise, and sweep speed.

Datasheet pdf 4.6 MB Version: R 10/11/2017

Mobile Interference Hunting System MX280007A Product Brochure

The Anritsu mobile interference hunting system automates the interference hunting process. Multiple measurements are automatically taken and processed using the MX280007A software. Using mapping software resident on a Windows laptop/tablet, an Anritsu handheld spectrum analyzer and an omnidirectional antenna, directions and voice prompts are provided in this system to guide the driver to the source of interference.

To learn more about the Mobile Interference Hunting System, download this product brochure now.

Brochure pdf 6.3 MB Version: F 10/11/2017

EU Declaration of Conformity for the K Coax Cable

This Declaration of Conformity is a special document issued by Anritsu to state that the product meets all of the applicable legislation and European directives.

Datasheets pdf 25.3 KB Version: A 10/9/2017

EU Declaration of Conformity for the V Coax Cable

This Declaration of Conformity is a special document issued by Anritsu to state that the product meets all of the applicable legislation and European directives.

Datasheets pdf 25.3 KB Version: A 10/9/2017

By Document Type

Mobile InterferenceHunter Software MX280007A Release History

This release history document provides the updates and enhancements in each version release of the Mobile InterferenceHunter Software MX280007A.

Drivers Software Downloads pdf 257.5 KB Version: V2.02 12/1/2017

Firmware Update for the Site Master S820E

This firmware update contains the latest upgrades for your instrument. Once downloaded, run the file on your computer to see the installation instructions. Release History

Drivers Software Downloads exe 76.5 MB Version: 2.90 10/23/2017

Firmware Revision History for the S820E

Full firmware release history for the S820E Microwave Site Master.

Drivers Software Downloads pdf 117.7 KB Version: 2.90 10/23/2017

PowerSuite Remote User Interface

PowerSuite is a demonstration program for the Anritsu ML24xxA Power Meters written in Visual Basic 6.0. It shows the many features available to you when using our Power Meter by using a PC as an interface to the device via a GPIB card or the RS232 Serial port.

Drivers Software Downloads zip 34.4 MB Version: A 10/19/2017

MS9740A Software

The files in the folder are as follows:
Software update files
Download manual
Release note
Operation Manual/v19.0
Remote Operation Manual/v11.0
SCPI Remote Operation Manual/v3.0
Labview Driver

MD5 : 4832f125d94a765639656595ac407932

Drivers Software Downloads zip 23.2 MB Version: 1.05.06 10/17/2017

Software Revision History for the S331P

Software release history for the S331P Site Master Ultraportable Cable and Antenna Analyzer.

Drivers Software Downloads pdf 67.6 KB Version: 2017.10.2 10/17/2017

Software Update for the Site Master S331P

This software update contains the latest upgrades for your instrument. Once downloaded, run the file on your computer to see installation instructions.

Drivers Software Downloads exe 265.1 MB Version: 2017.10.2 10/17/2017

Software Revision History for the MS2760A

Complete software release history for the MS2760A Spectrum Master Ultraportable Spectrum Analyzer.

Drivers Software Downloads pdf 262.8 KB Version: 2017.10.1 10/16/2017

Software Update for the Spectrum Master MS2760A

This software update contains the latest upgrades for the Spectrum Master MS2760A Ultraportable Spectrum Analyzer.

Drivers Software Downloads exe 113.3 MB Version: 2017.10.1 10/16/2017

IVI-C Installation Files V2017.9.1

IVI-C installer for Windows 7, 8 and 10 operating systems. Compatible with ShockLine software V2017.9.1.

Drivers Software Downloads exe 67.8 MB Version: 2017.9.1 10/4/2017

ShockLine VNA Software

Download the latest software for the ShockLine VNA family. This software works with the MS46121A/B, MS46122A/B, MS46322A/B, MS46522B and MS46524B Series ShockLine VNAs.

Note:
This installation may require your host to be re-booted to support updates to existing drivers.
This installation will require the insertion of services and drivers to your host. Please turn off all Web and Host Virus Detection Applications before starting the installation. Upon completion of the installation turn on your virus Detection Applications to their previous state.
For MS46122A using Windows 8, 8.1, or 10:
Before installing the ShockLine software, please follow the procedure outlined in the  manual driver

Drivers Software Downloads exe 178.9 MB Version: v2017.9.1 10/4/2017

Software Release Note for the ShockLine VNAs

Software release note for the MS46121B, MS46122B, MS46322B, MS46522B, and MS46524B ShockLine family of Vector Network Analyzers.

Drivers Software Downloads pdf 81.9 KB Version: 2017.9.1 10/4/2017

MX9083x2_Firmware_v208_E

Firmware and documents for MT9083x2 are contained in the zip file.

MD5 : 94868c8e8a57b8f59e1dde489705f9ed

Drivers Software Downloads zip 37.4 MB Version: 2.08 9/28/2017

MU909060A_v308a_E

The following Firmware and documents for MU909060A are contained in the zip file (v3.08a).
(MU909060A:v3.08, MX909060A:v3.08.02)

MD5 : 2d70f5f3e3a766dafdf020df6ca5715e

Drivers Software Downloads zip 63.8 MB Version: 3.08a 9/21/2017

Release Note V9.00 (Illustration)

This is the illustrated version of MT1000A/MT1100A release note. Some contents of release note are explained with figure.

Drivers Software Downloads pdf 17.6 MB Version: 9.00 9/19/2017

MT1000A_Software

Software of MT1000A.
Use it when NOT using the 100G Multirate Module MU100011A.
It supports operation with the following modules.

  • MU100010A 10G Multirate Module
  • MU100020A OTDR Module
  • MU100021A OTDR Module
  • MU100022A OTDR Module
  • MU100040A/B CPRI RF Module
  • MU100090A High-Accuracy GPS Disciplined Oscillator
The file size is large, so download after checking your bandwidth.

MD5 : 39cbc7a10b9d619063fd2112d80d7054

Drivers Software Downloads zip 453.1 MB Version: 9.00 9/19/2017

MT1100A_Software

Software of MT1100A.

MD5 : b223d8a129b7653bfb7b9ba75dfddeba

Drivers Software Downloads zip 682.5 MB Version: 9.00 9/19/2017

MX100001A windows control software

MX100001A windows control software.

MD5 : dcb3d42cc2e3b5d558af43cf5c71a60f

Drivers Software Downloads zip 64.7 MB Version: 9.00 9/19/2017

MX100001A windows control software

MX100001A windows control software.


MD5 : dcb3d42cc2e3b5d558af43cf5c71a60f

Drivers Software Downloads zip 64.7 MB Version: 9.00 9/19/2017

Network Master Pro/Flex Release Notes

Release information for the latest version of MT1000A/MT1100A

Drivers Software Downloads pdf 560.0 KB Version: 9.00 9/19/2017

By Product Category

Can a spectrum analyzer be connected to a cable that has DC voltage?

Yes, just don't exceed the maximum voltage that is normally described on the spectrum analyzer port

Can I get a maintenance manual for the MS2721B.

Yes, the part number is 10580-00177 and it can be ordered from your local Service Center.

What is the difference between an OSL calibration and FlexCal?

With the OSL calibration, you have to calibrate each time you change the frequency range. With the FlexCal, you can change the frequency range and you don't have to perform another calibration. FlexCal is great for troubleshooting purposes. The accuracy can be affected if your span is really narrow so for optimum accuracy, it is recommended to use the OSL calibration.

How do I calibrate my thru when my DUT has the same gender connector on the input and output?

Use the phase equal adapters provided in the calibration kit.  Refer to page 7-3 of your VNA operation manual for a detailed description on the use of phase equal adapters.

Can I use a 4-port test set extension with a "C" revision Lightning?

No, the 4-port test set extension requires option 15 which adds direct sampler access on the front panel. This option was not available for the "C" revision Lightnings.

Can I connect a printer to my S312D Site Master that is not on the printer list?

Yes but there is no guarantee that it will work. Only those printers listed have been tested and are known to work properly with the Site Master.

Can I use the 36584 4 port AutoCal module to calibrate my 37369D?

No, the 36584 AutoCal is only specified to 9 GHz and was designed to work with the Scorpion VNAs.

Can I use an Anritsu MA4701A sensor on a ML243xA series power meter.

Yes, the MA4701A can be used on the ML243xA power meters but since the pin configuration is different you will need an adapter which is part number MA2499B.

Can I use Agilent Vee with my MS462xB/D?

Yes.  While there are currently no drivers written, it is still possible to control the MS462xB/D with Agilent Vee using the GPIB commands.  Refer to the GPIB programming guide.

Can I change the Port Connectors on the 37000D?

Yes.  The universal test port connector on the Lightning allows the user to change the test port connectors to GPC-7, K, N, and 3.5mm for the 40GHz test sets and GPC-7, K, SSMA, and V for the 65GHz test sets.  A test port wrench, P/N 01-202, will be required.

Why does my Short/Open calibration standard not look like a short/open when I test it with a calibrated network analyzer?

All calibration standards have a length associated with them. This will appear as a phase offset when tested on a calibrated VNA. This additional phase length is accounted for on the calibration characterization file (cal disk).

Can I use my Lightning Calibration Kit, 365X on a Scorpion?

While the Scorpion will not read the cal file disk, it is possible to enter the calibration coeficients manually.  During the calibration process, the MS462xB/D will prompt the user for a connector type.  If the user selects "User Defined," the MS462xB/D will then allow the user to enter the calibration coefficients manually.

How can I improve a noisy trace on my VNA?

Reduce the IF bandwidth and increase averaging.

Can I improve my autocal thru calibration?

Yes, by using a thru update.

Can I use my Scorpion calibration kit, 375x, on a Lightning?

While the Lightning will not read the cal file disk, it is possible to enter the calibration coeficients manually.  During the calibration process, the 37000D will prompt the user for a connector type.  If the user selects "User Defined," the 37000D will then allow the user to enter the calibration coefficients manually.  The user must make sure that the measurement frequency does not exceed the calibration kit frequency.

I have downloaded the latest firmware for the MT8852A/B onto my PC. What is the firmware upgrade process for the MT8852A/B?

1. On the PC unzip the file downloaded for the firmware upgrade.

2. Connect the serial cable from the MT8852A/B to the PC. Make sure the PC is using COM port 1.

3. Press config button on the MT8852A/B. Scroll down using the down arrow to System feature and press the select key.

4. On the MT8852A/B scroll to Software update and press select. The following step must be performed in this order and must be done within a few seconds.

5. On the MT8852A/B Scroll to BootLoad.

6. Press select

7. On the PC click on H_Boot1. (double click) You should get a pop up window and it should show data transfer. The upgrade should take 7-10 minutes.

I need a Cable and Antenna Analyzer and VNA that I can use to test cable TV applications that have an impedance of 75 Ohms. Can I use the MS2024/26A on 75 Ohm systems?

Yes the MS2024/26A can be use to test 75 ohm systems. When using 75 ohm matching pads you are limited to 3GHz for your testing. You need to use a matching pad, part number 12N50-75B and 75 Ohm calibration components. The calibration components are:

22N75 Open/Short, DC to 3GHz, N(m) 75 ohms

22NF75 Open/Short, DC to 3GHz, N(f) 75 ohms

26N75A Precision Termination, DC to 3 GHz, N(m), 75 ohms

26NF75A Precision Termination, DC to 3 GHz, N(f), 75 ohms

I have an S332D with the Transmission Measurement option. If I turn on the Bias Tee while in the Transmission Measurement mode and then go to the Frequency Return Loss mode without turning the Bias Tee off does the DC voltage on the RF out port stay on?

Yes the DC voltage will still be present at the RF out port in this scenario. If you do not need the voltage for your test you should turn the Bias Tee off before going to the Frequency Return Loss mode to save battery power.

I need to do a DTF measurement from 1930 MHz to 1945 MHz on my Site Master. When I set F2 to 1945 MHz I get an error message "New Values Invalid".

Your data points needs to be changed to 130 Data points.  At 130 sata points you can have a span of 13 MHz or larger.  At 259 data points the minimum span is 25.9 MHz.  At 517 data points the minimum span is 51.7 MHz. In the DTF parameter screen it shows the maximum span setting in the Resolution parameter.

From the frequencies 250 - 320 MHz my MS2026A does not look correct. It has a saw tooth look between these frequencies. This was intermittent as a power off/on would fix it for a short time. Then I noticed the IF Cal is OFF warning.

Factory Calibration is OFF. Insure that the battery level is adequate for operation or that the temperature is within acceptable limits. Reset to factory defaults with either Factory Defaults, ESC+ON, or MASTER RESET, System + ON. Caution: Use of MASTER RESET, System + ON, will erase all user saved setups and measurement traces and return the unit to a factory default condition. If the error persists, then contact your Anritsu Service Center.