Skip to main content

Download Center

Search by product Model Number

By Document Type

Site Master S331D Maintenance Manual

This manual provides maintenance instructions for the Site Master Model S331D Cable, Antenna and Base Station Analyzer. It describes the product and provides performance verification procedures, parts replacement procedures, and a replaceable parts list.

Maintenance Manual pdf 1.9 MB Version: H 10/3/2012

Site Master S331D User Guide

User Guide for the Site Master S331D model.

User Guide pdf 1.6 MB Version: L 10/3/2012

Site Master Quick Reference Cards

This laminated card set is a Quick Reference guide to help you with the following measurements: Return Loss Return Loss Interpretation Distance To Fault Distance To Fault Interpretation Cable Loss

Instruction Sheet pdf 1.3 MB Version: A 2/13/2008

Site Master S33xD Programming Manual

Programming Manual for the Site Master S331D and the S332D models.

Programming Manual pdf 5.7 MB Version: C 1/17/2008

By Document Type

Anritsu Software Tool Box (Full Installer)

The Anritsu Software Tool Box contains tools to help you make the most of your Anritsu RF Handheld Instruments. This installer may not require internet access while running. See the software tools pages for details. Anritsu Software Tool Box includes Line Sweep Tools, Master Software Tools, Wireless Remote Tools, easyTest Tools, and easyMap Tools. This stand-alone installer will download all Anritsu software needed to install your chosen PC Tools software, and do so all in one file. This is ideal if you will be doing the installation on a computer without internet access. Windows 7, Windows 8 or Windows 10 computers may still need internet access to download the Microsoft .NET 3.5 suite of support files.

Drivers Software Downloads exe 389.5 MB Version: 1.21 8/13/2025

Updating Legacy Anritsu Handheld Instrument Firmware

This document provides an overview of the firmware update process using Anritsu’s Master Software Tools (MST). For detailed information about Master Software Tools, refer to the Help menu > Help Contents. For detailed information on the firmware update process refer to the User Guide for your Anritsu handheld instrument.

Drivers Software Downloads pdf 383.0 KB Version: C 7/31/2017

HHCL Version History

Release dates, Software Requirements, and Compatibility.

Drivers Software Downloads pdf 354.1 KB Version: 3.44 6/4/2008

Download Handheld Code Loader

Handheld Code Loader v3.44 Visit the Handheld Code Loader Home Page for quick access to the firmware, features, and version history (no registration required). Note: Master Software Tools (MST) now works on Site Master S311D, S331D, S312D, S332D and Cell Master MT8212B. We strongly recommend users to migrate to MST. This platform has numerous productivity advantages over the HHST and all future product enhancements will be done via MST. Visit the Master Software Tools (MST) Home Page for more information.

Drivers Software Downloads exe 7.0 MB 3/19/2008

Download Handheld Software Tools

Handheld Software Tools V6.61 (Release date: December 21, 2007) Handheld Software Tools has been replaced by Line Sweep Tools and will receive no further updates. Visit the Line Sweep Tools (LST) information page to learn more. Visit the Handheld Software Tools (HHST) information page for quick access to additional drivers, features, version history, etc.

Drivers Software Downloads exe 7.9 MB 12/21/2007

By Product Category

I've recently upgraded the firmware on my S331D and now under the DTF, I see an option for Optical. What is that?

The S331D when upgraded to Version 5.23 firmware or later has the internal capability to make Optical Distance To Fault  measurements.  An external Optical Distance to Fault Module is also needed to make the Optical DTF measurement.  This part number is ODTF-1.

I am using the Tripp Lite USB to serial adapter. I have verified the adapter is installed properly and the adapter shows up on Com 4 on my PC under Ports (Com & LPT). The port setting is port 4 in HHST. I have all baud rates set correctly and I still get an error in serial communications after several seconds.

If you have a wireless device enabled on your PC or laptop this can interrupt the serial communication.  Go to Network connections and verify your Wireless Network connection type LAN or high speed internet is disabled.  Even it says disconnected you should disabled it.  This has been known to help in cases where everything is set up properly.  Wireless devices such as Palm Pilots can cause this also so disable all wireless devices that you use.

Can I sweep an antenna with a TMAS on the line?

No. The majority of TMAS for cellular antennas will block the RF signal from the Site Master so the sweeping signal will only go as far as the TMAS and not reach the antenna.

Can I sweep antennas close to another RF source?

Yes but you need to be very careful that the RF from another Source is not going to exceed the 20 dBm max on the RF port.  Power in excess of 20 dBm can result in damage to the unit.

Can a .csv file that was converted from a .vna file of a VNA master be converted back to .vna using Master Software Tools?

No. If someone sends you a .csv file MST cannot be used to convert it back to a .vna file to be opened in MST.

What is the calibration temperature window for the cable & antenna analyzer in the Site Master and Cell Master?

The calibration goes out when the temperature has deviated more than 15 degrees from the temperature at which the calibration was performed. This information is also available in the instrument. Simply press SYS and then Status after performing the calibration. The instrument will show the current temperature and then Cal Temp Range will show up as Current Temperature +/- 15C.

Why will my S331C Site Master not download plots?

Try opening the plots one by one. You should run into one that will not open and this plot is most likely corrupted.  Unfortunately, when this is the case, there in nothing that can be done. Erase the plot and try your download again. 

What is a one port cable loss test?

Traditionally, measuring the insertion loss of an installed coaxial cable is a one-port reflection measurement since it is virtually impossible to connect both ends of the cable to test equipment. The measurement is made by placing a short on one end of the cable and measuring the return loss at the other end. The desired value, cable loss, is return loss divided by two, since the signal travels through the cable in both directions.

How do I reduce the side lobes in a DTF on a Site Master?

Windowing will  reduce the lobes depending upon their severity.  It is similar to an averaging or smoothing technique.  There are four windowing options available: Rectangular windowing – Normal mode of operation. Nominal side lobe – Some smoothing Low Side Lobe – More smoothing Minimum side lobe – Maximum smoothing

Are Anritsu PC applications for downloading files from the Site Master supported on 64 bit Windows OS's?

Currently Anritsu does not but is working diligently to provide a solution.

What methodolgy is used to derive GPS data for the Master products?

The GPS coordinates delivered by the instruments are based on the WGS-84 methodology of determining position.

When testing sites on power transmission towers do I need to worry about ESD damaging the Site Master?

Yes. If you are testing the line with the antenna attached, there is a good chance that the Site Master could be damaged by ESD. This happens because ESD gets onto the center conductor through the antenna's elements. It is safe to test with a load or short because there is no path for the ESD to get onto the center conductor.

What causes an Integrator Failure?

An integrator failure is typically caused by excessive RF power to the input of the Sitemaster. Different Sitemaster models have different damage levels that they can tolerate and newer models have improved immunity to overpower conditions. See the appropriate user manual for the damage level for your particular unit. One common way this overpower condition can be caused is by a high powered interfering carrier when testing with the antenna attached at a co-locate site. If the power level of the interference is too high it could cause damage to the Site Master. To find out if damage has occurred, disconnect the Site Master from the coax under test and if the integrator failure still occurs then there may be damage to the unit. To prevent this type of situation, check the power level on the antenna first using a power meter or power monitor (Options 29 or 5) to see if any power is present on the antenna before sweeping it.

When I select to display a plot from a database, the plot will not display and my mouse cursor remains an hour-glass.

This is a problem with the database operations. It is caused when more than 2 lines of information have been added into the Plot Description field even if the extra lines are blank. To fix this, select the Record then select Edit. Place the cursor at the end of the 2nd line of the Plot Description field. Left-click and hold down the mouse button and scroll down. The cursor will now be below the 2nd line. Press the Delete key on the keyboard to remove the extra lines. The cursor should now be at the end of the 2nd line. Either select another record or select Done. To prevent this from happening on the initial entry of Plot Descriptions, try to remember not to press the Enter key when done with the 2nd line entry.

What happens if the battery of my site master is completely discharged?

If a battery is allowed to totally discharge, the smart-memory capability of the battery may be lost, resulting in incorrect battery capacity readings or loss of communication with the battery.

What is the meaning of the LED indicators on the optional battery charger?

Each battery holder in the optional charger has an LED charging status indicator. The LED color changes as the battery is charged: Red indicates the battery is charging Green indicates the battery is fully charged Yellow indicates the battery is in a waiting state.  A yellow light may occur because the battery became too warm during the charge cycle.  In this case, the charger will allow the battery to cool off before continuing the charge. A yellow light may also indicate that the charger is alternating charge to each of the two batteries.

What is the specification for cable LDF12-50J?

Propagation Vel 88%  (.88) Atten/100ft @ 1920 MHz  3.13 dB  Atten/100ft @ 2000 MHz  3.20 dB   Atten/100ft @ 894 MHz  2.07 dB  Atten/100ft @ 960 MHz  2.15 dB Atten/100ft @ 1700 MHz  2.93 dB d This is not Anritsu made or sold cable.

What causes my Site Master to beep?

If a flashing LOW BATT indicator is accompanied by an audio beep at the end of each trace, the battery has approximately one minute of useable time remaining.

Is there any recommendation for Battery Life on a Site Master?

The NiMH battery will last longer and perform better if allowed to completely discharge before recharging. For maximum battery life, it is recommended that the NiMH battery be completely discharged and recharged once every three months.

Why can't I use the Code Loader to upgrade the firmware on my S331 Site Master?

The Code Loader can only be used to upgrade Site Master models that have the capability to upgrade the firmware through the serial port. The S331 uses an Eprom-based firmware which can only be upgraded by an Anritsu Service Center. The models that can not be upgraded with the Code Loader are: 110, 330, S110, S111, S330, S331, S330A with serial number range of 702xxx through 706xxx and S331A with serial number range of 702xxx through 706xxx.