Vector Network Analyzer 2300-480 Performance Verification Software User Guide

This manual supports the Anritsu 37000 Series VNA System Performance Verification Software, GPRG# 63420. This software is used with the Anritsu 37000 Series Vector Network Analyzers.

User Guide pdf 697.0 KB Version: B 7/19/2011

Lightning 37000D Series Maintenance Manual

This manual provides general service and preventive maintenance information for the Anritsu 37XXXD models of Vector Network Analyzer (VNA) systems.

Maintenance Manual pdf 996.7 KB Version: C 7/2/2007

Vector Network Analyzer 37000D Technical Datasheet and Configuration Guide

Support documentation for Lightning Network Analysis Solutions for Design and Manufacturing. P/N: 11410-00350

Datasheet pdf 399.8 KB Version: C 3/29/2007

AutoCal 36581NNF/81KKF/82KKF User's Guide

User guide for the Automatic VNA Calibrators 36581NNF, 36581KKF, and 36582KKF. This manual describes (1) the physical requirements, including test hardware, software, and computer resources necessary to setup a measurement and (2) how to start and use the software to control the calibration.

User Guide pdf 223.9 KB Version: E 3/26/2007

Lightning 37000D Series Operation Manual

This manual provides general information, installation, and operating information for the Model 37XXXD Vector Network Analyzer (VNA) system.

Operations Manual pdf 4.3 MB Version: B 2/2/2007

Lightning 37000D Series GPIB Quick Reference Guide

This appendix provides a quick reference to the 37XXXD GPIB Programming commands.

Programming Manual pdf 351.6 KB Version: A 9/2/2004

Lightning 37000D Series Programming Manual

This manual provides IEEE 488 bus (GPIB) programming information and data for all models of the Series 37000C Vector Network Analyzer. It contains the entire command set for programming all features. Consequently, not all of the codes documented in this manual apply to all models within the series (372XXD, 373XXD).

Programming Manual pdf 2.4 MB Version: A 9/2/2004

Lightning 372XXC/373XXC Maintenance Manual

This manual provides general service and preventive maintenance information for the Anritsu 372XXC/373XXC models of Vector Network Analyzer (VNA) systems.

Maintenance Manual pdf 1.8 MB Version: D 8/19/2004

Microwave Multiport Balanced VNA Technical Data Sheet

Anritsu’s Microwave Multiport Balanced VNA consists of a 37347C or 37247C 20 GHz Lightning Vector Network Analyzer (VNA), an SM5975 or SM5962 4-port test set, and the Navigator™ Multiport software (external PC is required and is not included). The SM5975 or SM5962 test set is a 2x4 switch matrix that allows either port on the VNA to connect with any of the 4 ports on the test set. The easy-to-use Navigator™ Multiport software provides full step-by-step direction, simplifying calibration, and speeding measurement throughput.

Datasheet pdf 229.5 KB Version: A 7/14/2004

373XXA Vector Network Analyzer Series Maintenance Manual

373XXA Vector Network Analyzer.

Maintenance Manual pdf 1.5 MB 3/23/2004

Lightning 37XXXC GPIB Quick Reference Guide

This appendix provides a quick reference to the 37XXXC GPIB Programming commands.

Programming Manual pdf 274.3 KB Version: D 3/19/2004

Lightning 37XXXC Operation Manual

This manual provides general information, installation, and operating information for the Model 37XXXC Vector Network Analyzer (VNA) system. (Throughout this manual, the terms VNA, 37XXXC VNA, and 37XXXC will be used interchangeably to refer to the system.) It also provides description and instructions for the Millimeter Wave System that can be added to the 371XXC.

Operations Manual pdf 6.1 MB Version: E 3/1/2004

Vector Network Analyzer 371XXC Maintenance Manual

This manual provides general service and preventive maintenance information for the ANRITSU 371XXC family of Vector Network Analyzer (VNA) systems.

Maintenance Manual pdf 2.6 MB Version: B 9/14/2002

AutoCal 2-Port Automatic Calibrators 3658x Technical Data Sheet

The 3658x series AutoCal® modules are automatic calibrators that provide fast, repeatable, and high-quality coaxial calibrations up to 40 GHz. These modules contain precisely characterized calibration standards that aid in the removal of normal systematic errors of Vector Network Analyzers.

Datasheet pdf 242.8 KB Version: C 8/20/2002

Vector Network Analyzer 372xxB Maintenance Manual

This manual provides general service and preventive maintenance information for the Anritsu 372xxB family of Vector Network Analyzer (VNA) systems.

Maintenance Manual pdf 1.6 MB Version: D 6/23/2000

Power Tools and Utilities 2300-218 Software User's Guide

Power Tools includes a hypertext help file that explains functions and their required parameters in detail. A good starting point for first time users.

User Guide pdf 30.2 KB Version: A 3/14/2000

Vector Network Analyzer 371xxA Maintenance Manual

This manual provides general service and preventive maintenance information for the Anritsu 371XXA family of Vector Network Analyzer (VNA) systems.

Maintenance Manual pdf 1.9 MB Version: D 7/23/1999

Vector Network Analyzer 372xxA Maintenance Manual

This manual provides general service and preventive maintenance information for the Anritsu 372XXA family of Vector Network Analyzer (VNA) systems.

Maintenance Manual pdf 2.8 MB Version: B 7/23/1996

By Document Type

Lightning Navigator™ Multi-Port Software

Download Instructions — Click on Download — Run the executable file and it will guide you through the rest of the installation. Supported VNAs: Lightning 37000D/E series

Drivers Software Downloads exe 19.0 MB Version: 5.17 9/18/2017

VNA FTP Utility Version 1.27

VNA FTP displays the VNA's Hard and Floppy drives alongside the PC's drives, similar to Windows Explorer. This permits moving, copying and deleting files within and between the two entities with a few mouse clicks. Download and Install Instructions: Download the file below and save it to your PC's hard drive. Unzip the file. Run the setup.exe file to begin the installation process.

Drivers Software Downloads exe 4.3 MB Version: 1.27 1/10/2017

CapVNA for Lightning VNAs

Capture VNA is a Windows program to capture, display, save, and print the graphical and text data from Anritsu's VNAs. The displayed data can be loaded from a floppy disk where it was previously saved at the VNA or captured directly from the VNA over the GPIB port. The displayed data can be saved in a variety of formats (bitmap, S2p, text, etc.) to the PC's internal disk drive or a network drive and printed to a local or network printer (including color). The data can also be copied to the Windows Clipboard to be imported into other Windows programs such as MS Word, Excel, Power Point, Photo Editor, Paint or Notepad. Download and Install Instructions: Download the file below and save it to your PC's hard drive. Unzip the file. Run the setup.exe file to begin the installation process.

Drivers Software Downloads 2.7 MB Version: v2.6.9 1/14/2014

Trace Manager version 1.30

This 16-bit Windows program captures and plots data traces from Anritsu VNAs. The data can be manipulated, archived and made available to other windows applications. Download and Install Instructions: Download the file below and save it to your PC's hard drive. Unzip the file. Run the setup.exe file to begin the installation process.

Drivers Software Downloads zip 4.3 MB 2/14/2006

Windows GPIB version 3.55

Windows GPIB is a windows program to send and receive program data over the GPIB in response to commands entered from the keyboard or from a command file. Windows GPIB currently only supports National Instruments GPIB boards. The human interface was designed to be more helpful, natural and user friendly than the National Instruments program WIBIC. Windows GPIB utility is a good tool for testing mnemonics and commands while developing Automated Test programs. Download and Install Instructions: Download the file below and save it to your PC's hard drive. Unzip the file. Run the setup.exe file to begin the installation process.

Drivers Software Downloads zip 1.4 MB 2/14/2006

Lightning Command Encyclopedia (LCE)

The Lightning Command Encyclopedia (LCE) is a searchable, Windows-based, fully integrated command databse for the Lightning Vector Network Analyzer.  The LCE provides command mnemonic names, descriptions and usage information, and is searchable by mnemonic, description, query command, application and user comment.  It is designed to serve as a rapid development tool to simplity the creation of 37XXX series remote control applications.  It provides everything necessary to create GPIB programs. Download Instructions Click on Download Now Save the file in a temporary folder on your PC's hard drive Extract all the installation files from the downloaded zip file Execute the setup.exe file.  This will begin the install and walk you through the entire procedure Current Version:  2.03

Drivers Software Downloads zip 7.9 MB 4/8/2004

By Product Category

I have lost the Basic Measurement software disks that came with the 37000D VNA. What is the part number for this so I can order it?

The part number of the Basic Measurement Software for the 37000D VNA’s is 2300-500. Please contact your local Anritsu Service Center for assistance.

What are the four S Paramaters?

S11 Forward Reflection represents the measurement in which the signal leaves port 1 and is reflected back to port 1. S21 Forward Transmission represents the measurement in which the signal leaves port 1 and is transmitted to port 2. S12  Reverse Transmission represents the measurement in which the signal leaves port 2 and is transmitted to port 1. S22  Reverse Reflection represents the measurement in which the signal leaves port 2 and is reflected back to port 2.

What is The display technology On the 37347D VNA?

The display is thin film transisor (TFT) LCD

How do I clear or sanitize the memory on my Lightning 37000 series Vector Network Analyzer?

Security Procedures for the 37XXX VNAs: This note describes the precautions to take when using the Anritsu Lightning 37XXX VNAs in a secure environment. There are different locations in the CPU which are used to store different parameters of the VNA, and an understanding of the contents of these locations and the procedures to clear them is important when working in secure environments. The following locations in the processor are used to store data and other parameters. Memory Description DRAM Running firmware code, Application downloads and drives. Contents are completely erased when system power is turned off. SRAM Stores last front panel set-up, calibration data tables, and state storage. Also stores data when user selects Save front panel set up and cal date on memory. Contents are saved even after power off, since it is backed up by a battery. System will have to be reset to erase data (see erasing memory). CPU Flash Contains boot up code used to run the VNA firmware upon boot up of the instrument. This location doesn't save any user data and is not accessible to the user. Memory contents cannot be removed by turning power off or resetting the instrument. But there is no user accessible data on the CPU flash. Hard Disk Saves user files, including: calibrations, S2p data, test data, graphical data, instrument states, set-up parameters. Memory cannot be deleted by turning power off or resetting the instrument. The hard disk will have to be formatted to erase all the contents. This can be done through the front panel. Erasing Memory To erase instrument memory in a secure environment where the VNA may be shared between different users. Different Reset Levels 1) Pressing the key on the front panel: defaults current state, erases memory location (SRAM) that saves current set-up and calibration data and clears trace memory 2) Pressing the key and the key: defaults current state, erases the memory location (SRAM) that saves current set-up and calibration data and clears trace memory. In addition, it also clears internal memories (memory 1-10) that are used to store set-up and cal data. 3)Pressing the key and the key: Similar to and in addition also clears reserved parameters. This is the highest level of system reset. Reserved parameters include GPIB addresses, Coax/WG cal kit info, test set configuration (including millimeter-wave, panorama), external source configuration, receiver mode, output (printer), DUT protection, adapter removal info, and color configuration. Erase is accomplished by writing "10101010"'s into these memory locations which meet the DoD wipe memory routine (DoD 5220.22-M). NOTE: For highly secure environments, it is recommended that the hard drive be removed using option 4A; and the system should be operated using an external hard drive. 3700/4A - Option 4A, External SCSI-2 Hard Disk Drive compatibility (Internal HDD removed, External SCSI-2 PCMCIA drive ordered separately). In addition, the following SCSI drives are available for use with option 4A: 2000-1397 Lightning SCSI-2 External PCMCIA Drive (for use in the United States) Includes: PCMCIA Drive with Power Supply, SCSI-2 Interface Cable, and pre-programmed Memory Card. (Requires Option 4A installed in 37000 VNA) 2000-1398 Lightning SCSI-2 External PCMCIA Drive (for use in Europe, except United Kingdom) 2000-1399 Lightning SCSI-2 External PCMCIA Drive (for use in the United Kingdom) 2000-1400 Lightning SCSI-2 External PCMCIA Drive (for use in Australia) The external hard drive can remain in the secure area or be destroyed (disintegrated, incinerated, pulverized, shredded or melted). In a nonsecure environment, a spare external hard drive can be used.

What is the dedicated GPIB used for in the 37000D series Lightning VNA?

It is used to connect to external peripherals and/or instrumentation for network analyzer controlled operations (e.g. plotters, frequency counters, frequency synthesizers and power meters).

How many setups can be stored in the Lightning series VNA?

Ten front panel states (no calibration) can be stored and recalled from non-volatile memory locations. The current front panel setup is automatically stored in non-volatile memory at instrument power down. When power is applied, the instrument returns to its last front panel setup.

How often should my 37000D be factory calibrated?

The suggested calibration interval is 1 year however the customer's application of the product may require a different calibration interval.

How do I restore my 37000D back to factory default?

In order to restore the 37000D to factory default simply push the "Default Program" button, then the "0" button. This will restore the system to factory default settings including clearing the calibration kit information. The Calibration Kit will need to be reloaded.

How stable is the Signal source frequency in the Lightning series VNA?

Temperature: <5 x 10-E9 over 0 deg. to 55 deg. Celsius range Aging: <1 x 10-E9/day

What is the fast CW operation in the 37000D series Lightning series VNA?

The Fast CW is an ideal mode of operation to attain rapid data over GPIB. To achieve a fast measurement rate, the display is not updated and only the raw S-parameter or user-defined parameter of the active channel is measured.

What is the System GPIB in the 37000D series Lightning VNA used for?

It is used to connect to an external controller for use in remote programming of the network analyzer. The address can be set from the front panel and can range from 1 to 30.

What type of external trigger can be used in Lightning series VNA?

External TTL triggering for 37000D series VNA measurement. 10 K ohm input impedance, BNC female.

What is the size of internal hard disk drive for Lightning series VNA?

It is 0.5 GB, used to store and recall measurement and calibration data and front-panel setups. File names can be 1 to 8 characters long, and must begin with a character, not a number. Extensions are automatically assigned.

What are the input power supply voltages that the 37000D series VNA supports?

The power requirements are: 85-240 volts, 48-63 Hz. The VNA automatically senses the voltage line present.

Our Anritsu 37347C VNA is getting the following error messages: 6024 PHS LCK FAIL DE and 5110 RF PWR UNLEVELED. If I disable port 1 the errors go away.

It is apparent that something has failed in the down converter of the signal source of your VNA. If you look at the block diagrams for your VNA, you will see that the VNA has only one internal signal source that is used for S parameter measurements. This signal source is a 2 - 20 GHz YIG oscillator that is used direct with filters for frequencies above 2 GHz. Below 2 GHz, this source is down converted with a fixed frequency oscillator, filtered and amplified. It is this down converter assembly that has apparently failed in your VNA based on the symptoms you described. There is no capability to substitute an alternative source to make S parameter measurements. The best course of action is to send your VNA to an Anritsu service center for repair.

Can I use non-Anritsu Calibration Kits to calibrate my 37000D?

Yes, calibration coefficients for non-Anritsu calibration kits can be entered manually through the user defined connector type. During the calibration process, the 37000D will prompt the user for a connector type. If the user selects "User Defined," the 37000D will then allow the user to enter the calibration coefficients manually.

What are the different sweep types that the Signal source of Lightning series VNA supports?

It supports Linear, CW, Marker, or N-Discrete point sweeps.

What is the Ext. Analog In on the rear panel connector in Lightning 37000D series VNA?

It is +/- 50 volt input for displaying external signals on the LCD, the connector is BNC female.

How do I use a sliding load?

The first step in using the sliding load is to check and adjust, if necessary, the width of the pin depth gauge. Then the pin depth of the sliding load must be set to minus .0002 This pin gap insures that the shoulders of the male and female connectors are sufficiently spaced so as not to meet, yet they are close enough that the characteristic impedance at the interface is not adversely affected. After the pin gap is set, the sliding load must be mated to the test port of the VNA when prompted by the analyzer during calibration. Always position the slider as close to the test port as possible when making connection. This will aid in centering the pin. It is easier to mate the connectors when they are in the vertical plain, again to make it easier to align the two connectors. Gently tap the shaft of the sliding load if the center conductor is obviously misaligned. When visually centered, carefully mate the sliding load to the test port connector. The Anritsu VNA will prompt the user through all the steps to accomplish a sliding load calibration. When prompted, insert the fixed load, this termination sets the characteristic impedance for frequencies below 2 GHz.