BERTWave Series Remote Control Operation Manual
조작 메뉴얼
pdf 4.2 MB
Version: 29th Edition
2026/07/01
The recent rapid increases in data volumes at network equipment, servers, and storage due to increasing use of smartphones, cloud computing, FTTx rollout, video streaming, etc., seem likely to increase even further in future. To cope with demand, many appliances and facilities are using digital signals exceeding the Gbit/s band. Dealing with these high-speed signals requires paying attention not only to the digital aspects but also to analog-type behavior, and care is required in choosing tools for monitoring these signals. This document discusses the key points when handling digital signals exceeding 10 Gbit/s from the perspective of measurement tools.
테크니컬 노트
pdf 1.0 MB
2017/07/14
유저 가이드
pdf 738.9 KB
2017/06/09
MP2100A/MP2101A/MP2102A BERTWave Operation Manual
조작 메뉴얼
pdf 8.2 MB
2016/01/13
MX210001A Jitter Analysis Software Operation Manual
조작 메뉴얼
pdf 2.7 MB
2016/01/13
MX210002A Transmission Analysis Software Operation Manual
조작 메뉴얼
pdf 2.2 MB
2016/01/13
All-in-One Simultaneous Waveform Simulation, Jitter Analysis, Eye Pattern Measurement and Eye Mask Test
팜플렛
pdf 1.6 MB
2016/01/05
This document explains how to measure the extinction ratio using sampling oscilloscopes; it is necessary because the measured value must be synchronized with the measuring instrument acting as the reference. The measurement method, Correction Factor calculation and input procedure are described using the MP2100A BERTWave as an example.
퀵 reference guide
pdf 822.2 KB
2014/11/13
This document explains some typical remote sequences making use of the MP2100A functions and speed. Using the remote sequences described in this document and selecting the best commands for optical module production from the MP2100A embedded remote commands will help you configure an easy-to-use efficient optical module test system.
application note
pdf 634.8 KB
2014/10/31
The all-in-one MP2100A BERTWave series supporting simultaneous BER and eye-pattern measurements is ideal for both R&D and manufacturing tests because it increases efficiency and cuts measurement costs by eliminating time consuming setup.
팜플렛
pdf 2.5 MB
2013/11/15
Product Introduction for the MP2100A BERTWave Series
제품의 소개
pdf 2.9 MB
2013/11/14
The MP2100A BERTWave is a new-concept measuring instrument. Simultaneous BER and EYE/Pulse Scope measurements using this all-in-one tester increase efficiency and cut measurement costs by eliminating time-consuming setup. The MP2100A BERTWave series with excellent cost-performance is ideal for both R&D and manufacturing tests.
리플렛
pdf 153.6 KB
2013/11/14
Simultaneous BER measurements, Eye/Pulse analysis and Jitter analysis using BERTWave increase efficiency and cut measurement time by eliminating time consuming setup. Fully supported LTE CPRI v4.1 bit rates (6.14G, 4.92G, 3.07G, 2.46G, 1.23 Gbit/s) make the BERTWave ideal for LTE CPRI optical transceiver mobile evaluation.
리플렛
pdf 388.0 KB
2013/11/14
Ideal probe for GHz-band sampling oscilloscope, Choice of 10:1 or 20:1 attenuation ratio, Low capacity input ideal for monitoring high-speed signal waveforms, Short input ground lead ideal for high-frequency circuit evaluation
리플렛
pdf 543.9 KB
2013/11/14
Wide 2000-kHz (max.) loop bandwidth supporting OC-48 measurements in full compliance with ITU-T G.984 for reduced jitter components at waveform monitoring.
리플렛
pdf 197.2 KB
2012/11/16
MP2100A-007 Single-Channel Electrical BERT, Optical/Single-Ended Electrical Scope, MP2100A-086/MP2102A-086 LPF (H) for Multi 10G
리플렛
pdf 242.9 KB
2012/11/02
The eye pattern is a useful tool for assessing the integrity of digital signals. The ones and zeroes of a data stream are superimposed to form an eye pattern, providing a good representation of how the data has been affected by a transmission link. Statistical measurements such as extinction ratio and Q-factor are often performed on the eye pattern for compliance testing of devices and transmission paths. These provide good pass/fail criteria, but lend little information as to what may be degrading the signal path.
테크니컬 노트
pdf 795.1 KB
2012/08/15
To cope with the rapid increases in data volumes, data centers are introducing high-speed interconnects with transmission speeds faster than 10 Gbit/s between servers. However, in conflict with these speed increases, there is increasing demand for lower power consumption as well as cost reductions. Furthermore, higher jitter levels and degraded waveforms are becoming a problem. Various measuring instruments, such as Sampling Scopes (Eye Pattern Analyzer) and BERTs are being used to classify and analyze jitter components such as DJ, RJ, etc., affecting communications quality over fibre channel, 10GbE, USB, PCI, etc. Increasing bit rate speeds require higher accuracy from measuring instruments used for these measurements, but the dependency of sampling oscilloscopes on the instrument’s own intrinsic jitter in the trigger clock circuits and its effect on the measurement results cannot be ignored sometimes.
테크니컬 노트
pdf 1.4 MB
2012/06/29
To cope with the rapid increases in data volumes, data centers are introducing high-speed interconnects between servers with transmission speeds faster than 10 Gbit/s. However, in conflict with these speed increases, there is increasing demand for lower power consumption as well as cost reductions. Furthermore, higher jitter levels and degraded waveforms are becoming a problem. Various measuring instruments, such as sampling scopes (Eye Pattern analyzer) and BERTs are being used to classify and analyze jitter components, such as DJ, RJ, etc., that affect communications quality over Fibre Channel, Infiniband, 10GbE, USB, PCI, etc., high-speed serial transmission standards used in data communications and computing.
application note
pdf 1.3 MB
2012/06/29
The MP2100A BERTWave series supports signal source (PPG), sampling oscilloscope, and BER measurement functions. Installing the MX210002A Transmission Analysis Software in the all-in-one MP2100A makes waveform, Eye Margin, BER and S21 measurements simple and fast.
리플렛
pdf 756.9 KB
2012/02/03