| Model |
KXL7534AWCSE |
| X-ray output |
Tube voltage 30 to 60 kV, tube current 0.4 to 3.3 mA, output 100 W |
| Safety |
X-ray leakage maximum 1.0 μSv/h or less, prevention of x-ray leakage by safety devices |
| Display |
15-inch color TFT LCD |
| Operation method |
Touch panel (with touch buzzer) |
| Detection area1, 2 |
Maximum width 390 mm, maximum height 220 mm |
| Belt width |
420 mm |
| Preset memory |
200 |
| Belt speed3 / Maximum product weight4 |
10 to 60 m/min, maximum 5 kg |
| Power requirements5 |
100 Vac to 240 Vac, single phase, 47 Hz to 63 Hz, 535 VA or less (standard) |
| Mass6 |
240 kg |
| Environmental conditions |
Temperature: 0°C to 35°C, Relative humidity: 30% to 85%, non-condensing |
| Protection class |
Conveyor: IP66 Other parts: IP40 (IP66 as optional) |
| Exterior |
Stainless steel (SUS304) |
1 : The product size should fall below the detection area.
2 : The maximum product length is 300 mm.
3 : Variable depending on Product No.
4 : Sum total of product weight on the conveyor.
5 : Allowable power fluctuation range is ±10%.
6 : Mass without option.