PIM Master MW82119A Maintenance Manual

This manual provides maintenance instructions for Anritsu PIM Master model MW82119A.

維護手冊 pdf 14.9 MB Version: E 2018/2/15

Passive Intermodulation (PIM) in In-building Distributed Antenna Systems (DAS)

As mobile operators upgrade existing in-building distributed antennna systems (DAS) to include LTE frequency bands, the probability of harmful passive intermodulation (PIM) increases. With low PIM components and careful construction techniques, operators are able to reduce interference caused by PIM and maximize site performance. Unlike impedance mismatches, which reduce signal level regardless of location, the nonlinearities that produce PIM have varying impact depending on where they are located in the network. This application note begins with a review of decibel math and insertion loss calculations, followed by a discussion of the impact of insertion loss on PIM performance in distributed antenna systems (DAS).

應用說明 pdf 1.6 MB Version: B 2016/6/7

Power Meter Measurement Guide

This Measurement Guide documents the Power Meter and the High Accuracy Power Meter for the following Anritsu instruments: BTS Master, Site Master, Spectrum Master, and Cell Master.

度量指南 pdf 2.6 MB Version: H 2016/4/19

PIM Test Reports

This application note describes the transferring of measurements from your PIM Master MW82119B to a computer to run reports and how to generate graphical and tabular reports using Line Sweep Tools (LST).

應用說明 pdf 1.2 MB Version: C 2015/12/8

Why only one PIM standard in PIM Master accessory kits?

Only one PIM standard is required to calibrate the Distance-to-PIM (DTP) feature, and to verify that the PIM Master is operating properly. For this reason, Anritsu only supplies one 1775 MHz PIM standard with its 2000-1745-R and 2000-1746-R PIM Master accessory kits.

技術說明 pdf 1.0 MB Version: C 2015/11/4

Testing Distributed Antenna Systems (DAS)

Distributed Antenna Systems (DAS) are being installed in large numbers to support growing demand for in-building wireless services. Needs range from capacity enhancements for large stadiums to coverage enhancements inside office buildings, tunnels and subterranean areas not served by outdoor networks. DAS can be designed as “Passive” systems, using RF cable and dividers to distribute signals to remote antennas within the venue, or as “Active” systems that use optical fiber to distribute signals to remote amplifiers throughout the venue. Which solution to choose depends on many variables, including budget, objective (coverage or capacity), size of the building and number of operators that will be sharing the system.

應用說明 pdf 4.9 MB Version: A 2015/11/2

PIM Master Equipment Verification Process

This brief user guide provides instructions on the cleaning, calibration and verification of the PIM Master MW82119A.

使用者手冊 pdf 638.2 KB Version: E 2015/10/29

PIM Master Hard Case Accessory Kit 2000-1746-R Technical Data Sheet

The 2000-1746-R accessory kit includes the RF components, tools, and cleaning supplies needed to support Passive Intermodulation (PIM) testing at a typical cellular installation. The low PIM termination and RF adapters included in this kit support PIM testing of one- or two-port devices with any combination of Type N(m), Type N(f), 7/16 DIN(m), or 7/16 DIN(f) RF connectors. The contents are packaged in a padded transit case for maximum protection while transporting to and from the test location.

資料表 pdf 304.3 KB Version: C 2015/10/29

PIM Master Backpack Accessory Kit 2000-1745-R Technical Data Sheet

The 2000-1745-R accessory kit includes the RF components, tools, and cleaning supplies needed to support Passive Intermodulation (PIM) testing at a typical cellular installation. The low PIM termination and RF adapters included in this kit support PIM testing of one- or two-port devices with any combination of Type N(m), Type N(f), 7/16 DIN(m), or 7/16 DIN(f) RF connectors. A padded backpack is provided for transporting the kit components to and from the test location.

資料表 pdf 465.0 KB Version: C 2015/10/29

PIM Master MW82119A User Guide

System overview and basic operating instructions for the Anritsu PIM Master, Portable Passive Intermodulation Analyzer MW82119A

使用者手冊 pdf 21.2 MB Version: J 2015/8/3

Configuring the Anritsu PIM Master for Wireless Browser Control

Browser enabled remote control brings unsurpassed flexibility to the Anritsu PIM Master. It is now possible to control the PIM Master using a wide variety of web browsers running on Wi-Fi enabled devices. Since the control software is served by the instrument, it is no longer necessary to install and run application software on the controlling device. Rather, a customer’s existing web browsing software (Safari, Internet Explorer, Google Chrome, etc.) can be used to control the PIM Master from a remote location. This flexibility makes remote control of the PIM Master more convenient for field personnel. This application note details the setup and use of the PIM Master MW82119A/B for browser based control.

應用說明 pdf 3.1 MB Version: C 2015/7/23

Using Distance-to-PIM (DTP) and Distance-to-Fault (DTF) trace overlay to speed site repair

Distance-to-PIM (DTP) technology from Anritsu greatly reduces the time required to resolve PIM issues at macro sites as well as inbuilding systems. Real-time trace overlay on the PIM Master enables technicians in the field to understand more clearly what they are seeing by comparing PIM fault locations to known “PIM markers” and known reflections in the system. Together, these features simplify the Passive Intermodulation (PIM) troubleshooting process, enabling faster site repairs.

應用說明 pdf 4.6 MB Version: A 2015/6/30

PIM Master Transmit Frequency Range

The MW82119A/B PIM Master from Anritsu is a family of high power, battery operated PIM test instruments designed for maximum portability. These instruments utilize a filter combiner to maximize RF efficiency and minimize battery consumption during use. The F1 and F2 frequency range for each analyzer has been designed to cover the maximum possible range of IM3 frequencies for that band. The fact that some frequencies in the downlink band are not able to be selected (guard band frequencies) has no impact on the instrument’s ability to test the full range of possible IM3 frequencies.

應用說明 pdf 2.0 MB Version: E 2015/4/27

PCS / AWS band PIM testing

The PIM Master™ MW82119A, frequency option 193 is designed to support Passive Intermodulation (PIM) testing at both PCS (1900 MHz) and AWS band (1700/2100 MHz) cell sites. This application note provides a detailed summary of the PCS and AWS spectrum and provides guidance for PIM testing cell sites operating in these frequency bands.

應用說明 pdf 1.8 MB Version: C 2015/3/11

PIM Master MW82119A Online Help System

Battery-operated, high power Passive Intermodulation (PIM) testing solution for the major wireless standards in use around the world. The PIM Master’s small size and light weight, combined with battery operation, make it the ideal solution for verifying PIM performance at difficult to access sites such as Remote Radio Head (RRH) installations or indoor Distributed Antenna Systems (DAS). Use Anritsu's Online Help System to learn more about the operation and programming of the PIM Master MW82119A battery-operated, high power portable, passive intermodulation analyzer.

線上說明系統 htm 161.5 KB Version: B 2014/4/9

Calibration Due Date

Anritsu recommends a calibration interval of 12 months for its PIM Master instruments. A new feature has been added to the PIM Master firmware to assist customers in monitoring the calibration status of their instrument. This application note explains this new feature.

應用說明 pdf 1.5 MB Version: A 2013/11/6

Mitigating External Sources of Passive Intermodulation (PIM)

External PIM sources can be a challenge regardless of the environment in which they are encountered. Discussed in this paper is the most effective method to mitigate external PIM.

白皮書 pdf 2.8 MB Version: A 2013/10/8

按文件類型

Anritsu Software Tool Box (Full Installer)

The Anritsu Software Tool Box contains tools to help you make the most of your Anritsu RF Handheld Instruments. This installer may not require internet access while running. See the software tools pages for details. Anritsu Software Tool Box includes: Line Sweep Tools — Analyze Cable, Antenna, and PIM traces, as well as generate reports. This works with DAT, VNA, and PIM files. Master Software Tools — Work with spectrum analyzer, interference analyzer, and transmitter test measurements as well as generate reports.
Wireless Remote Tools — Remotely monitor and control many Anritsu handheld RF instruments over Wi-Fi or Ethernet cables.

easyTest Tools — Create work instructions that can be ran on Anritsu handheld RF instruments.

easyMap Tools — Create maps for Anritsu handheld spectrum analyzers to simplify coverage measurements and interference hunting.

驅動程式/軟體下載 exe 385.8 MB Version: 1.16 2018/3/23

Anritsu Software Tool Box (Web Installer)

The Anritsu Software Tool Box contains tools to help you make the most of your Anritsu RF Handheld Instruments. This installer requires internet access while running. See the software tools pages for details.

Line Sweep Tools — Analyze Cable, Antenna, and PIM traces, as well as generate reports. This works with DAT, VNA, and PIM files.
Master Software Tools — Work with spectrum analyzer, interference analyzer, and transmitter test measurements as well as generate reports.
Wireless Remote Tools — Remotely monitor and control many Anritsu handheld RF instruments over Wi-Fi or Ethernet cables.
easyTest Tools — Create work instructions that can be ran on Anritsu handheld RF instruments.
easyMap Tools — Create maps for Anritsu handheld spectrum analyzers to simplify coverage measurements and interference hunting.

驅動程式/軟體下載 exe 401.0 KB Version: 1.09 2018/1/9

PIM Master MW82119A Firmware Release History

Firmware release history for the Anritsu MW82119A Passive Intermodulation (PIM) Analyzer.

驅動程式/軟體下載 pdf 331.5 KB Version: 2.30 2016/5/9

Firmware Update for the PIM Master MW82119A

This firmware update contains the latest upgrades for your instrument. Once downloaded, run the file on your computer to see the installation instructions.

Release History

驅動程式/軟體下載 exe 26.6 MB Version: 2.30 2016/5/9

Wireless Remote Access Tool for the PIM Master MW82119A

The Wireless Remote Access Tool for PIM Master allows you to control the PIM Master remotely with this software running on a Windows 7 (or earlier) laptop or tablet via a Wi-Fi router attached to the Ethernet port of the PIM Master. Your PIM Master requires firmware version V1.04 or higher for this to function properly. Release History

驅動程式/軟體下載 exe 294.8 MB Version: v1.00 2013/3/21