The Site Master S331E and S361E is a handheld cable and antenna analyzer designed to make
Return Loss, VSWR, Cable Loss, and Distance-T
o-Fault (DTF) measurements in the field.
The S332E and S362E is an integrated multi-functional test instrument that eliminates the need to carry and learn multiple test sets. In addition to the cable and antenna measurements, the S332E and S362E can be configured to include a Spectrum Analyzer, 2-port Transmission Measurement, Interference Analyzer with Interference Mapping capabilities, Coverage Mapping, Channel Scanner, CW Signal Generator, AM/FM/PM Analyzer, PIM Analyzer, Power Meter, and High Accuracy Power Meter. P/N: 11410-00484
Datasheet
pdf 5.4 MB
Version: AE
29/08/2019
The Site Master S331E and S361E is a handheld cable and antenna analyzer designed to make
Return Loss, VSWR, Cable Loss, and Distance-To-Fault (DTF) measurements in the field.
The cable and antenna analyzer also includes 1-port phase and smith chart measurements.
The 2-port transmission measurement option includes two power levels and access to a
built-in 32 volt bias tee (Option 10). In addition to the cable and antenna measurements, the S332E and S362E can be configured to include a Spectrum Analyzer, 2-port Transmission Measurement, Interference Analyzer with Interference Mapping capabilities, Coverage Mapping, Channel Scanner, CW Signal Generator, AM/FM/PM Analyzer, PIM Analyzer, Power Meter, and High Accuracy Power Meter. P/N: 11410-00516
Brochure
pdf 16.2 MB
Version: T
27/08/2019
Overview of RF and Microwave instruments available to meet a variety of solutions. Featuring the frequency range, measurements, and other key features. P/N: 11410-00800
Brochure
pdf 18.2 MB
Version: M
27/08/2019
A small 2 page flyer to showcase the right tools needed to achieve best in class network reliability. P/N: 11410-00855
Leaflet
pdf 1.7 MB
Version: F
29/07/2019
Discover Anritsu's best-in-class tools which will help your technicians and engineers optimize all areas of your network and elevate your network reliability to best-in-class. P/N: 11410-00617
Brochure
pdf 1.6 MB
Version: F
16/07/2019
This document is an industry review of techniques and procedures for evaluation of RF network testing. P/N: 11410-00700
White Paper
pdf 827.0 KB
Version: B
17/06/2019
Anritsu is the leader of high frequency microwave connector technology and is driven by an ongoing commitment to exceed customer needs. Anritsu created and trademarked the K Connector with coverage to 40 GHz, along with a complete family of 40 GHz test equipment. It was an immediate success and today is used on many commercial components, test fixtures, and
defense systems. P/N: 11410-00235
Catalog
pdf 12.3 MB
Version: T
05/06/2019
This SCPI Programming Manual provides information for remote operation of the E series instruments using commands sent from an external controller via Ethernet or USB connection. P/N: 10580-00256
Programming Manual
pdf 4.6 MB
Version: V
01/05/2019
This measurement guide describes the Common Public Radio Interface (CPRI) analyzer test
and measurement functions of Anritsu RF and Microwave Handheld Instruments. P/N: 10580-00415
Measurement Guide
pdf 10.6 MB
Version: K
01/05/2019
Quick overview of the features, specifications, options, and accessories available in this 2 page flyer. P/N: 11410-00625
Brochure
pdf 928.9 KB
Version: F
04/04/2019
Compare models with spectrum analysis and review the different tests they can perform. P/N: 11410-00559
Leaflet
pdf 1,007.6 KB
Version: H
03/04/2019
The Site Master User Guide is part of a set of manuals that describe all of the instrument
functions and their use. This manual covers the instrument overview, system functions and
other common features, along with a brief guide to basic measurement concepts and setups. P/N: 10580-00252
User Guide
pdf 11.8 MB
Version: U
31/01/2019
This Measurement Guide describes Electromagnetic Field (EMF) measurement functions available as Option 444 on Anritsu RF and Microwave Handheld Instruments. Option 444 must be used in conjunction with an Anritsu isotropic antenna, at a frequency range that is within specification of the instrument and antenna used. P/N: 10580-00455
Measurement Guide
pdf 3.6 MB
Version: A
20/12/2018
Poster showcasing the RF and Microwave Handheld analyzers options. Features Cable and Antenna Analyzers, Base Station Analyzers, Spectrum Analyzers, Vector Network Analyzers, and PIM Analyzers. P/N: 11410-00571
Brochure
pdf 262.8 KB
Version: P
24/04/2018
This Measurement Guide describes the test and measurement functions of Anritsu RF and
Microwave Handheld Instruments. Basic spectrum analyzer functions are included with most
Anritsu handheld instruments.
Measurement Guide
pdf 21.6 MB
Version: M
30/03/2018
In this paper we will focus on losses due to reflections. These reflections are measured using a cable and antenna analyzer such as the Anritsu Site Master. Operators often specify that the worst case reflections (return loss) over the operating frequency range of the system must be 18 dB. But, what exactly does that mean? It means the reflected signal must be 18 dB lower than the signal that is transmitted into the system. Or, another way of looking of this is that the reflected signal must be less than 1/64th the magnitude of the signal transmitted into the system. Where did this limit come from? In many cases, it has been based on what an operator knows is possible when high quality components are installed according to the manufacturer’s specifications using good workmanship. As feed systems become shorter and antenna systems are required to operate over broader frequency ranges, achieving an 18 dB return loss may not be practical.
White Paper
pdf 711.3 KB
Version: B
29/03/2018
Transport, Optical & RF Testing for all Elements of the C-RAN Network.
Anritsu has a long history of testing all aspects of the C-RAN. Our instruments evolve to meet the new challenges of testing the C-RAN
networks being rolled out today. Put our experience to work for you!
Brochure
pdf 3.2 MB
Version: B
29/03/2018
The purpose of an in-building wireless (IBW) system is to provide enhanced network coverage
and/or capacity when the existing macro network is not able to adequately service the
demand. Coverage may be poor due to high penetration losses caused by the building
structure or due to low emissivity glass installed to improve the thermal performance of the building. In dense urban environments, adjacent buildings may create an RF barrier that blocks coverage from nearby macro sites. Tall buildings typically have poor coverage on
upper floors since macro site antennas, many floors below, are specifically designed to
suppress energy radiating above the horizon. Capacity may be an issue in venues such as
stadiums, coliseums and convention centers where many thousands of users may be trying to
simultaneously access the network.
Application Note
pdf 1.8 MB
Version: C
28/03/2018
PIM Hunter, a passive intermodulation test probe, helps field technicians more quickly discover the precise location of external PIM sources at cell sites. The PIM Hunter test probe enables field professionals to use traditional interference hunting techniques to accurately locate external PIM sources for optimum wireless network performance. P/N: 11410-01005
Leaflet
pdf 1.3 MB
Version: B
27/03/2018
This guide provides important notices, warranty, safety, and regulatory compliance information for Anritsu RF and microwave handheld analyzers. Be sure to read these important notices before operating the equipment.
Online Help System
htm 185.8 KB
Version: H
21/11/2017