ShockLine VNAs are simple, economical, and deliver great performance. With their compact and durable design, they are ready-to-use right out of the box. Across the entire family, you’ll find coverage for a wide frequency range with fast test times and optimal throughput. Excellent corrected directivity and minimal drift reduces measurement uncertainty and enables smaller guard bands for improved yield in production. The ShockLine family also delivers fast measurement speeds with high dynamic range that minimizes test times and maximizes throughput in automated and manual test applications. With Anritsu’s world-class customer support and a 3-year warranty, you’ll also have the support and service you need when you need it.

 
MS46522B
MS46522B / MS46524B
MS46122B
Models
Frequency Range
55 GHz to 92 GHz
(Extended E-band)
50 kHz to
8.5/20/43.5 GHz
1 MHz to 8/20/43.5 GHz
Dynamic Range
(@10 Hz IFBW)
≥106 dB,
60 GHz to 67 GHz
≥110 dB,
>67 GHz to 87 GHz
≥ 98 dB,
>87 GHz to 90 GHz
≥140 dB,
50 MHz to 2 GHz
≥130 dB,
2 GHz to 6 GHz
≥114 dB,
6 GHz to 40 GHz
≥100 dB,
40 GHz to 43.5 GHz
≥85 dB,
1 MHz to 10 MHz
≥100 dB,
>10 MHz to 8 GHz
≥95 dB,
>8 GHz to 14 GHz
≥100 dB,
>14 GHz to 40 GHz
≥97 dB,
>40 GHz to 43.5 GHz
Directivity
>= 42 dB
(50 kHz to 43.5 GHz) with database calibration
>= 42 dB
(50 kHz to 43.5 GHz) with database calibration
>= 42 dB
(1 MHz to 43.5 GHz ) with database calibration
Trace Noise (rms)
(100 Hz IFBW)
≤0.004 dB, 60 GHz to 90 GHz
≤0.004 dB, 300 kHz to 40 GHz
≤0.006 dB, 20 MHz to 40 GHz
Port Power
Variable output level range:
-60 to 0 dBm
Variable output level range:
-30 to +15 dBm
High State: +5, -3 dBm
Low State: -20 dBm
Measurement
Speed, Typical
(optimal sweep setup)
30 µs/point
30 µs/point
130 µs/point
Major Options
Time Domain, UFX, and Rack-Mount
Time Domain,
Advanced Time Domain,
Bias Tees, UFX,
and Rack-Mount
Time Domain, UFX, and Rack-Mount
Hardware Communication Interface
LAN
LAN
LAN
Calibration
SOLT, SOLR, SSLT,
SSST, LRL/LRM, WG,
Microstrip, Thru Update
SOLT, SOLR, SSLT,
SSST, LRL/LRM, WG,
Microstrip,
AutoCal/SmartCal,
Thru Update
SOLT, SOLR, SSLT,
SSST, LRL/LRM, WG,
Microstrip,
AutoCal/SmartCal,
Thru Update
Sweep Type
Freq: Linear, Log, CW,
Segmented
Power: Linear
Freq: Linear, Log, CW,
Segmented
Power: Linear
Freq: Linear, Log, CW,
Segmented
Max Number
of Points
20,001
20,001
16,001
1 Specified using two MS46121B instruments with option 21 at 30 Hz IFBW with external reference
2 Specified with two MS46131As with option 12 (PhaseLync) and high isolation mode on

 
ms46122b
ms46131a
MS46121b
Models
Frequency Range
1 MHz to 8/20/43.5 GHz
1 MHz to 8/20/43.5 GHz
40 MHz to 4 GHz
150 kHz to 6 GHz
Dynamic Range
(@10 Hz IFBW)
≥85 dB,
1 MHz to 10 MHz
≥100 dB,
>10 MHz to 8 GHz
≥95 dB,
>8 GHz to 14 GHz
≥100 dB,
>14 GHz to 40 GHz
≥97 dB,
>40 GHz to 43.5 GHz
>=97 dB,
1 MHz to 8.5 GHz
>=98 dB,
>8.5 GHz to 20 GHz
>=102 dB,
>20 GHz to 40 GHz
>=99 dB,
>40 GHz to 43.5 GHz2
Scalar Transmission: 80 dB
(typical, 150 kHz to 6 GHz)¹
Directivity
>= 42 dB
(1 MHz to 43.5 GHz) with database calibration
>= 42 dB
1 MHz to 43.5 GHz) with database calibration
>= 42 dB
(150 kHz to 6 GHz)
Trace Noise (rms)
(100 Hz IFBW)
≤0.006 dB, 20 MHz to 40 GHz
<= 0.011 dB, 1 Mhz to 43.5 GHz2
0.02 dB (typical),
150 kHz to 6 GHz
Port Power
High State: +5, -3 dBm
Low State: -20 dBm
High state: +0 dBm
Low state: -20 dBm
Nominal Output:
-5 dBm (150 kHz to 46 MHz)
+3 dBm (>46 MHz to 4 GHz)
-5 dBm (>4 GHz to 6 GHz)
Measurement
Speed, Typical
(optimal sweep setup)
130 µs/point
170 µs/pt
120 µs/point
Major Options
Time Domain and UFX
(Rack-Mount standard)
Time Domain
PhaseLync Synchronization
Low Pass Time Domain
(Band Pass TD standard)
Hardware Communication Interface
USB
USB
USB
Calibration
SOLT, SOLR, SSLT,
SSST, LRL/LRM, WG,
Microstrip,
AutoCal/SmartCal,
Thru Update
SOLT, SOLR, SSLT,
SSST, LRL/LRM, WG,
Microstrip,
AutoCal/SmartCal,
Thru Update
SOL, Scalar Thru
(with option 21),
AutoCal/SmartCal
Sweep Type
Freq: Linear, Log, CW,
Segmented
Freq: Linear, Log, CW,
Segmented
Freq: Linear, Log, CW,
Segmented
Max Number
of Points
16,001
16,001
20,001
1 Specified using two MS46121B instruments with option 21 at 30 Hz IFBW with external reference
2 Specified with two MS46131As with option 12 (PhaseLync) and high isolation mode on