Skip to main content

Download Center

Search by product Model Number

By Document Type

ElectroMagnetic Field Measurements Product Brochure

ElectroMagnetic Field (EMF) Measurement System is designed to measure radiation compliance with various national standards for personal safety set by governmental regulatory authorities. Many countries have mandated EMF safety testing in areas where cellular or other high power transmission antennas are located. P/N: 11410-00838

Brochure pdf 5.6 MB Version: H 12/21/2022

Anritsu's RF and Microwave Test and Measurement Solutions Product Brochure

Overview of RF and Microwave instruments available to meet a variety of solutions. Featuring the frequency range, measurements, and other key features. P/N: 11410-00800

Brochure pdf 11.4 MB Version: AC 12/21/2022

Anritsu RF and Microwave Handheld Analyzers Solution Poster

Poster showcasing the RF and Microwave Handheld analyzers options. Features Cable and Antenna Analyzers, Base Station Analyzers, Field Master Pro, Spectrum Analyzers, Vector Network Analyzers, and PIM Analyzers. P/N: 11410-00571

Brochure pdf 325.0 KB Version: T 12/21/2022

Spectrum Analysis Solutions Leaflet

Compare models with spectrum analysis and review the different tests they can perform. P/N: 11410-00559

Leaflet pdf 931.3 KB Version: J 12/19/2022

LMR Master S412E Technical Data Sheet

The S412E offers a solution for installing and maintaining public safety systems. The S412E combines a high performance receiver and spectrum analyzer in a handheld vector network analyzer plus a powerful vector signal generator with internally adjustable power from 0 dBm to –130 dBm. P/N: 11410-00486

Datasheet pdf 7.0 MB Version: AV 11/11/2022

LMR Master S412E Maintenance Manual

This manual provides maintenance instructions for the Anritsu LMR Master S412E.

Maintenance Manual pdf 12.3 MB Version: T 10/25/2022

Product Information, Compliance, and Safety for Anritsu Handheld Instruments

This guide provides important notices, warranty, safety, and regulatory compliance information for Anritsu RF and microwave handheld analyzers. Be sure to read these important notices before operating the equipment. P/N: 10100-00065

Datasheet pdf 1.4 MB Version: F 10/24/2022

Precision RF & Microwave Components Catalog

Anritsu is the leader of high frequency microwave connector technology and is driven by an ongoing commitment to exceed customer needs. Anritsu created and trademarked the K Connector with coverage to 40 GHz, along with a complete family of 40 GHz test equipment. It was an immediate success and today is used on many commercial components, test fixtures, and defense systems. P/N: 11410-00235

Catalog pdf 13.3 MB Version: AD 7/26/2022

Evaluation of RF Network Testing White Paper

This document is an industry review of techniques and procedures for evaluation of RF network testing. P/N: 11410-00700

White Paper pdf 996.1 KB Version: C 6/14/2022

LMR Master S412E Programming Manual

This SCPI Programming Manual provides information for remote operation of the S412E LMR Master using commands sent from an external controller through the Ethernet or USB connection. P/N: 10580-00319

Programming Manual pdf 4.9 MB Version: AB 5/3/2022

Land Mobile Radio Analyzer and Coverage Measurement Measurement Guide

This Measurement Guide documents Land Mobile Radio signal analysis functions of the Anritsu LMR Master handheld instrument. Anritsu currently supports measurement of Narrowband FM Analog and digital transmitter Land Mobile Radio technologies. P/N: 10580-00243

Measurement Guide pdf 22.4 MB Version: AF 5/3/2022

LMR Master S412E Help

Help is a compilation of user documentation for easier viewing and navigation. P/N: 10450-00026 | OHS | version L | 05/03/2022

Online Help System html 185.8 KB Version: L 5/3/2022

LMR Master S412E User Guide

The LMR Master User Guide is part of a set of manuals that cover all of the instrument functions and their use. This manual covers the instrument overview, system functions, and other common features, along with a brief guide to basic measurement concepts and setups. P/N: 10580-00318

User Guide pdf 13.2 MB Version: AB 5/3/2022

Training and Certification Course Catalog

This is a comprehensive catalog of all available instructor-led certification courses offered by Anritsu. It includes course descriptions, the handheld instruments that are used in the training, the number of days required for each type of class and what a student can expect to learn. P/N: 11410-00397

Catalog pdf 6.5 MB Version: E 4/12/2022

TETRA Signal Generator Quick Start Guide

The Anritsu TETRA Signal Generator provides you with a PC utility to quickly create a T1 TCH/7.2 test signal for Base Station sensitivity testing as per the TETRA test specification to be used with the LMR Master S412E. This document also provides the necessary instructions on how to generate custom TETRA DL patterns. P/N: 10580-00425

Quick Start Guide pdf 1.6 MB Version: B 12/1/2021

Network Installation and Maintenance Testing Instruments Solutions Brochure

This Solution Brochure showcases Optical Measuring Instruments, Transport and Ethernet Testing, Mobile Wiress Communication Measuring Instruments, Signal Analyzers, Spectrum Analyzers, VNAs, and RF Microwave products.

Brochure pdf 1.3 MB 10/8/2020

LMR Master Quick Fact Sheet

This two page quick overview of the LMR Master covers key specifications, accessories, and options that are available. P/N: 11410-00634

Brochure pdf 916.9 KB Version: J 5/27/2020

LMR Master S412E Product Brochure

The LMR Master S412E is a compact handheld multi-function analyzer that has been specifically developed for technicians and engineers who install and maintain public safety, utility and private mobile communications systems. P/N: 11410-00594

Brochure pdf 22.6 MB Version: U 5/27/2020

Spectrum Analyzer Measurement Guide

This Measurement Guide describes the test and measurement functions of Anritsu RF and Microwave Handheld Instruments. Basic spectrum analyzer functions are included with most Anritsu handheld instruments. P/N: 10580-00349

Measurement Guide pdf 21.8 MB Version: P 4/28/2020

Rack Mount Accessory Installation Guide

This document provides instructions for mounting Anritsu handheld instruments in to the Anritsu Rack Mount Accessory, part number 66864. P/N:10580-00338

Installation Guide pdf 3.5 MB Version: C 2/7/2020

By Document Type

Firmware Update for the LMR Master S412E

This firmware update contains the latest upgrades for your instrument. Installation instructions are included in the download.

Drivers Software Downloads exe 50.2 MB Version: 4.50 9/22/2022

LMR Master S412E Firmware Release History

Firmware release history for the LMR Master S412E.

Drivers Software Downloads pdf 319.9 KB Version: 4.50 9/22/2022

TETRA DL Signal Generator

The TETRA DL Signal Generator is a Windows application which provides users with the ability to generate custom base station (DL) pattern files. Users can customize the MCC, MNC, BCC, LAC and frequency values. The customized patterns can then be imported into an LMR Master S412E running firmware Version 4.40 or higher.

Drivers Software Downloads zip 620.4 MB Version: 1.08 12/1/2021

Signal Generator Patterns for LMR Master S412E

Signal Generator Patterns for P25, P25 P2, DMR2, NXDN, PTC, NBFM, and TETRA modes.

Drivers Software Downloads zip 176.8 MB Version: 1.12 8/7/2019

LMR Patterns history

History of the changes made to the LMR Patters file. Read this document to discover what patterns were added and when they were added.

Drivers Software Downloads pdf 89.2 KB Version: 1.12 8/7/2019

Anritsu Software Tool Box (Full Installer)

The Anritsu Software Tool Box contains tools to help you make the most of your Anritsu RF Handheld Instruments. This installer may not require internet access while running. See the software tools pages for details. Anritsu Software Tool Box includes Line Sweep Tools, Master Software Tools, Wireless Remote Tools, easyTest Tools, and easyMap Tools. This stand-alone installer will download all Anritsu software needed to install your chosen PC Tools software, and do so all in one file. This is ideal if you will be doing the installation on a computer without internet access. Windows 7, Windows 8 or Windows 10 computers may still need internet access to download the Microsoft .NET 3.5 suite of support files.

Drivers Software Downloads exe 388.8 MB Version: 1.18 4/10/2019

70774 Instrument Test Software

Works with VNA Masters MS202xB, MS203xB, MS202xC, and MS203xC and LMR Master S412E.

Drivers Software Downloads zip 7.8 MB Version: 1.03 5/8/2018

Anritsu Software Tool Box (Web Installer)

The Anritsu Software Tool Box contains tools to help you make the most of your Anritsu RF Handheld Instruments. This installer requires internet access while running. See the software tools pages for details. Anritsu Software Tool Box includes Line Sweep Tools, Master Software Tools, Wireless Remote Tools, easyTest Tools, and easyMap Tools.

Drivers Software Downloads exe 401.0 KB Version: 1.09 1/9/2018

TETRA Base Station Receiver Sensitivity Signal Generator

The Anritsu TETRA Signal Generator provides users with a PC utility to quickly create a T1 TCH/7.2 test signal for Base Station Receiver Sensitivity (BSRS) testing as per the TETRA test specification to be used with the Anritsu LMR Master S412E handheld instruments with the TETRA Analyzer option and hardware compatible with BSRS testing.

Drivers Software Downloads zip 620.3 MB Version: 1.00 9/27/2016

Updating Anritsu Handheld Instrument Firmware

This document provides an overview of the firmware update process. For further details, please refer to the user guide for your Anritsu handheld instrument.

Drivers Software Downloads pdf 344.1 KB 10/30/2015

P25 Control Channel Decoder

Python script for decoding P25 Control Channel information

Drivers Software Downloads zip 12.1 KB Version: V.2 4/10/2012

NXDN Control Channel Decoder

Python script for decoding NXDN Control Channel information

Drivers Software Downloads 6.1 KB 5/17/2011

By Product Category

I have a S331E and when I convert my files from .VNA to .DAT, the CW is “ON”. How do I turn it off?

  This has happened because the RF Immunity is set for “Low” on the instrument and when you convert them from .VNA to .DAT using Master Software Tools, CW is “ON”. You have to set RF Immunity for “High”. To do this press “Sweep/Setup” and on your right hand side you will see the soft key “RF Immunity”. Press to underscore “High”. Unfortunately, you will have to retake your measurements. This can not be changed after saving.

Can you tell me the difference between the 2000-767-R and the 2000-1618-R?

The only difference is the frequency range. The 2000-767 is DC to 4 GHz and the 2000-1618-R is DC to 6 GHz. There is also a female 7/16 Open/Short/Load part number 2000-768-R and 2000-1619-R. 2000-768-R frequency range is DC to 4GHz and 2000-1619-R is DC to 6GHz.

How do I copy files from my internal memory to my USB memory stick?

  The steps below detail copying a file from internal memory to an external flash drive.   NOTE: Select the files to copy in the top window and the location for the files to be copied to in the bottom window.   Insert a USB drive into either USB Type A port of the Site Master.   From the File main (shift/file (#7 key)) menu, press the “Copy (soft key)” submenu key. The Copy submenu and Copy dialog box are displayed (picture below).   Select the file(s) to copy. To select multiple files, highlight the first then press the “Select or De-Select” key to keep the file selected.  NOTE: (Press again to de-select if you choose not to copy the file.) The file will be outlined in blue. Repeat with all the files to copy. To display files in a folder, select the folder and press the Enter key.   Press the Scroll key and highlight the USB drive and press “select or de-select” soft key in the lower window using the touch screen or the Up/Down arrow keys or Thumb Wheel. NOTE: The Scroll submenu key toggles between Src (top window) and Dst (bottom window). Basically, the top window (src) is where you copy from and the bottom (dst) is where those files are going to.   Press the Copy key to copy the files to the flash drive.       NOTE:   If you want to check and see if those files have been copied, simply press the Scroll soft key (to get to your Src or source box), use your Up/Down arrows or Thumb Wheel to get to your USB Drive and press “Enter”. 

How do I copy files from my internal memory to my USB memory stick?

  The steps below detail copying a file from internal memory to an external flash drive.   NOTE: Select the files to copy in the top window and the location for the files to be copied to in the bottom window.   Insert a USB drive into either USB Type A port of the Site Master.   From the File main (shift/file (#7 key)) menu, press the “Copy (soft key)” submenu key. The Copy submenu and Copy dialog box are displayed (picture below).   Select the file(s) to copy. To select multiple files, highlight the first then press the “Select or De-Select” key to keep the file selected.  NOTE: (Press again to de-select if you choose not to copy the file.) The file will be outlined in blue. Repeat with all the files to copy. To display files in a folder, select the folder and press the Enter key.   Press the Scroll key and highlight the USB drive and press “select or de-select” soft key in the lower window using the touch screen or the Up/Down arrow keys or Thumb Wheel. NOTE: The Scroll submenu key toggles between Src (top window) and Dst (bottom window). Basically, the top window (src) is where you copy from and the bottom (dst) is where those files are going to.   Press the Copy key to copy the files to the flash drive.       NOTE:   If you want to check and see if those files have been copied, simply press the Scroll soft key (to get to your Src or source box), use your Up/Down arrows or Thumb Wheel to get to your USB Drive and press “Enter”. 

How do I copy files from my internal memory to my USB memory stick?

The steps below detail copying a file from internal memory to an external flash drive. NOTE: Select the files to copy in the top window and the location for the files to be copied to in the bottom window. Insert a USB drive into either USB Type A port of the Site Master. From the File main (shift/file (#7 key)) menu, press the “Copy (soft key)” submenu key. The Copy submenu and Copy dialog box are displayed (picture below). Select the file(s) to copy. To select multiple files, highlight the first then press the “Select or De-Select” key to keep the file selected. NOTE: (Press again to de-select if you choose not to copy the file.) The file will be outlined in blue. Repeat with all the files to copy. To display files in a folder, select the folder and press the Enter key. Press the Scroll key and highlight the USB drive and press “select or de-select” soft key in the lower window using the touch screen or the Up/Down arrow keys or Thumb Wheel. NOTE: The Scroll submenu key toggles between Src (top window) and Dst (bottom window). Basically, the top window (src) is where you copy from and the bottom (dst) is where those files are going to. Press the Copy key to copy the files to the flash drive. NOTE: If you want to check and see if those files have been copied, simply press the Scroll soft key (to get to your Src or source box), use your Up/Down arrows or Thumb Wheel to get to your USB Drive and press “Enter”.

How do I add options to my S331D Site Master?

Some options for the S331D Site Master require additional hardware or calibration factors to be loaded into the unit so the work needs to be done in either an Anritsu service center or at the Morgan Hill, CA facility.  For other options, these can be added via a license file and instructions on how to complete this process are shown below:    Generating an Instrument Config File and Installing A New License File To automatically queue the Anritsu website for updates, you must configure the Master Software Tools (MST) Internet Settings. 1. Run the MST program. 2. Connect to the instrument. 3. Generate a Config File a. Pull down the Sync menu and highlight Device Status and Options to open the submenu.   Get Options Highlighted (config file)   b. Click Get Options (Config File). The Save Config File window opens.     c. Go to the folder where the license file was previously stored. d. Highlight the file and press the Open button. The filename format is model-spaceserialnumber.license. e. MST will install the new license into the instrument. After the installation is complete, a dialog appears.   “Instrument options successfully upgraded. Cycle power on the instrument to begin using the new features”   f. Follow the instruction. g. Verify the new option(s) are listed on the boot up screen.

What is a Z540 calibration?

The Standard Service Program provides economic per-incident service for most Anritsu products at a pre-established standard price. All service is provided on a return to Anritsu service center basis. Two types of Z540-compliant calibration services are offered. Standard Calibration provides the minimum level of documentation necessary for compliance with ANSI/NCSL Z540-1-1994. For those customers who need a full set of pre- and post-calibration data, we offer Premium Calibration.

Is there a rack mount kit available for handheld instruments?

There is a rack mount kit available for current models of handheld instruments. The part number is 66864. This kit can be used with the following models: S331E, S332E, S361E, S362E, MT8221B, MT8222B, MT8212E, MT8213E, S412E, MS2024B, MS2025B, MS2034B, MS2035B, MS2026C, MS2028C, MS2036C, MS2038C, MS2722C, MS2723C, MS2724C, MS2725C, MS2726C, MS2711E, MS2712E, MS2713E, and MS2721B

Where can I find information on how to erase my product's memory?

Please contact your Sales Representative or Technical Support at 1-800-ANRITSU (1-800-267-4878) for memory erasure /letter of volatility information.