Skip to main content

Download Center

Search by product Model Number

By Document Type

Site Master S3xxE User Guide

The Site Master User Guide is part of a set of manuals that describe all of the instrument functions and their use. This manual covers the instrument overview, system functions and other common features, along with a brief guide to basic measurement concepts and setups. P/N: 10580-00252

User Guide pdf 11.8 MB Version: U 1/31/2019

Site Master S331E, S332E, S361E, and S362E Technical Data Sheet

The Site Master S331E and S361E is a handheld cable and antenna analyzer designed to make Return Loss, VSWR, Cable Loss, and Distance-T o-Fault (DTF) measurements in the field. The S332E and S362E is an integrated multi-functional test instrument that eliminates the need to carry and learn multiple test sets. In addition to the cable and antenna measurements, the S332E and S362E can be configured to include a Spectrum Analyzer, 2-port Transmission Measurement, Interference Analyzer with Interference Mapping capabilities, Coverage Mapping, Channel Scanner, CW Signal Generator, AM/FM/PM Analyzer, PIM Analyzer, Power Meter, and High Accuracy Power Meter. P/N: 11410-00484

Datasheet pdf 5.4 MB Version: AC 1/31/2019

Precision RF & Microwave Components Catalog

Anritsu is the leader of high frequency microwave connector technology and is driven by an ongoing commitment to exceed customer needs. Anritsu created and trademarked the K Connector with coverage to 40 GHz, along with a complete family of 40 GHz test equipment. It was an immediate success and today is used on many commercial components, test fixtures, and defense systems. P/N: 11410-00235

Catalog pdf 11.6 MB Version: P 9/26/2018

E-Series Handheld Instruments Programming Manual

This SCPI Programming Manual provides information for remote operation of the following Anritsu instruments using commands sent from an external controller via Ethernet or USB connection: S331E, S332E, S361E, S362E Site Master, MS2711E, MS2712E, MS2713E Spectrum Master, and MT8212E, MT8213E Cell Master. P/N: 10580-00256

Programming Manual pdf 3.0 MB Version: U 9/17/2018

World's Most Trusted Family of RF and Microwave Handheld Analyzers Product Brochure

Compare the features and options available on a variety of handheld analyzers. Select the right solution to get the job done. P/N: 11410-00309

Brochure pdf 4.4 MB Version: AB 9/10/2018

Site Master S331E, S332E, S361E, and S362E Product Brochure

The Site Master S331E and S361E is a handheld cable and antenna analyzer designed to make Return Loss, VSWR, Cable Loss, and Distance-To-Fault (DTF) measurements in the field. The cable and antenna analyzer also includes 1-port phase and smith chart measurements. The 2-port transmission measurement option includes two power levels and access to a built-in 32 volt bias tee (Option 10). In addition to the cable and antenna measurements, the S332E and S362E can be configured to include a Spectrum Analyzer, 2-port Transmission Measurement, Interference Analyzer with Interference Mapping capabilities, Coverage Mapping, Channel Scanner, CW Signal Generator, AM/FM/PM Analyzer, PIM Analyzer, Power Meter, and High Accuracy Power Meter. P/N: 11410-00516

Brochure pdf 16.8 MB Version: P 8/24/2018

CPRI RF Analyzer and BBU Emulator Measurement Guide

This measurement guide describes the Common Public Radio Interface (CPRI) analyzer test and measurement functions of Anritsu RF and Microwave Handheld Instruments. P/N: 10580-00415

Measurement Guide pdf 10.3 MB Version: J 7/24/2018

Anritsu RF and Microwave Handheld Analyzers Solution Poster

Poster showcasing the RF and Microwave Handheld analyzers options. Features Cable and Antenna Analyzers, Base Station Analyzers, Spectrum Analyzers, Vector Network Analyzers, and PIM Analyzers. P/N: 11410-00571

Brochure pdf 262.8 KB Version: P 4/24/2018

C-RAN Solutions Brochure

Transport, Optical & RF Testing for all Elements of the C-RAN Network. Anritsu has a long history of testing all aspects of the C-RAN. Our instruments evolve to meet the new challenges of testing the C-RAN networks being rolled out today. Put our experience to work for you!

Brochure pdf 3.2 MB Version: B 3/29/2018

The Impact of Return Loss on Base Station Coverage in Mobile Networks

In this paper we will focus on losses due to reflections. These reflections are measured using a cable and antenna analyzer such as the Anritsu Site Master. Operators often specify that the worst case reflections (return loss) over the operating frequency range of the system must be 18 dB. But, what exactly does that mean? It means the reflected signal must be 18 dB lower than the signal that is transmitted into the system. Or, another way of looking of this is that the reflected signal must be less than 1/64th the magnitude of the signal transmitted into the system. Where did this limit come from? In many cases, it has been based on what an operator knows is possible when high quality components are installed according to the manufacturer’s specifications using good workmanship. As feed systems become shorter and antenna systems are required to operate over broader frequency ranges, achieving an 18 dB return loss may not be practical.

White Paper pdf 711.3 KB Version: B 3/29/2018

Site Master S33xE and S36xE Quick Fact Sheet

Quick overview of the features, specifications, options, and accessories available in this 2 page flyer.

Brochure pdf 891.2 KB Version: E 3/28/2018

Understanding IBW In-Building Wireless: DAS to Small Cells Application Note

The purpose of an in-building wireless (IBW) system is to provide enhanced network coverage and/or capacity when the existing macro network is not able to adequately service the demand. Coverage may be poor due to high penetration losses caused by the building structure or due to low emissivity glass installed to improve the thermal performance of the building. In dense urban environments, adjacent buildings may create an RF barrier that blocks coverage from nearby macro sites. Tall buildings typically have poor coverage on upper floors since macro site antennas, many floors below, are specifically designed to suppress energy radiating above the horizon. Capacity may be an issue in venues such as stadiums, coliseums and convention centers where many thousands of users may be trying to simultaneously access the network.

Application Note pdf 1.8 MB Version: C 3/28/2018

Installation, Maintenance and Optimization Solutions Flyer

A small 2 page flyer to showcase the right tools needed to achieve best in class network reliability.

Leaflet pdf 3.0 MB Version: D 3/28/2018

Site Master S3xxE Help

This guide provides important notices, warranty, safety, and regulatory compliance information for Anritsu RF and microwave handheld analyzers. Be sure to read these important notices before operating the equipment.

Online Help System htm 185.8 KB Version: H 11/21/2017

2-Port Transmission Measurement Guide

This Measurement Guide documents 2-port Transmission Measurement (Option 21) and Bias Tee (Option 10) for the Site Master, Spectrum Master, and Cell Master.

Measurement Guide pdf 1.8 MB Version: D 11/15/2017

Product Information, Compliance, and Safety for Anritsu Handheld Instruments

This guide provides important notices, warranty, safety, and regulatory compliance information for Anritsu RF and microwave handheld analyzers. Be sure to read these important notices before operating the equipment.

Datasheet pdf 1.3 MB Version: C 11/15/2017

Cable and Antenna Analyzer Measurement Guide

The Site Master, Cell Master, and PIM Master (MW82119B with Option 331) offer a wide range of cable and antenna measurements: Return Loss, VSWR, Cable Loss, Distance-To-Fault RL, Distance-To-Fault VSWR, 1-Port Phase, and Smith Chart. This manual provides setup and measurement procedures for each measurement. It also includes a line sweep fundamentals overview section. P/N: 10580-00241

Measurement Guide pdf 2.4 MB Version: C 11/15/2017

Understanding Cable & Antenna Analysis

The cable and antenna system plays a crucial role of the overall performance of a Base Station system. Degradations and failures in the antenna system may cause poor voice quality or dropped calls. From a carrier standpoint, this could eventually result in loss of revenue.

White Paper pdf 1.5 MB Version: F 10/24/2017

CPRI Technology Product Selection Guide

Anritsu now offers a CPRI RF option on several of our handheld test devices.

Download this product guide to select the correct test device for your needs.

Selection Guide pdf 3.8 MB Version: D 10/3/2017

Wireless Travel Router 2000-1752-R Installation Guide

This guide provides general information, configuration and operation instructions for the 2000-1752-R wireless travel router.

Installation Guide pdf 1.2 MB Version: D 9/25/2017

By Document Type

Anritsu Software Tool Box (Full Installer)

The Anritsu Software Tool Box contains tools to help you make the most of your Anritsu RF Handheld Instruments. This installer may not require internet access while running. See the software tools pages for details. Anritsu Software Tool Box includes Line Sweep Tools, Master Software Tools, Wireless Remote Tools, easyTest Tools, and easyMap Tools. This stand-alone installer will download all Anritsu software needed to install your chosen PC Tools software, and do so all in one file. This is ideal if you will be doing the installation on a computer without internet access. Windows 7, Windows 8 or Windows 10 computers may still need internet access to download the Microsoft .NET 3.5 suite of support files.

Drivers Software Downloads exe 388.8 MB Version: 1.17 2/13/2019

Firmware Update for the Site Master S36xE

This firmware update contains the latest upgrades for your instrument. Once downloaded, run the file on your computer to see the installation instructions.

Drivers Software Downloads exe 61.8 MB Version: 3.30 10/30/2018

Firmware Revision History for the S33xE and S36xE

Firmware release history for the Site Master S331E, S332E, S361E, and S362E Cable and Antenna Analyzers.

Drivers Software Downloads pdf 596.9 KB Version: 3.30 10/30/2018

Anritsu Software Tool Box (Web Installer)

The Anritsu Software Tool Box contains tools to help you make the most of your Anritsu RF Handheld Instruments. This installer requires internet access while running. See the software tools pages for details. Anritsu Software Tool Box includes Line Sweep Tools, Master Software Tools, Wireless Remote Tools, easyTest Tools, and easyMap Tools.

Drivers Software Downloads exe 401.0 KB Version: 1.09 1/9/2018

Updating Anritsu Handheld Instrument Firmware

This document provides an overview of the firmware update process. For further details, please refer to the user guide for your Anritsu handheld instrument.

Drivers Software Downloads pdf 344.1 KB 10/30/2015

By Product Category

I have a S331E and when I convert my files from .VNA to .DAT, the CW is “ON”. How do I turn it off?

 

This has happened because the RF Immunity is set for “Low” on the instrument and when you convert them from .VNA to .DAT using Master Software Tools, CW is “ON”. You have to set RF Immunity for “High”. To do this press “Sweep/Setup” and on your right hand side you will see the soft key “RF Immunity”. Press to underscore “High”. Unfortunately, you will have to retake your measurements. This can not be changed after saving.

I saved my measurements as a JPEG and a .DAT file. How do I view them on my S332E?

Currently the instrument is only able to create these files, not view them.  However, you can see some text information in the instrument through the “Copy or Delete” functionality such as the title accompanied with the extension (.JPG or .DAT).   JPEGs will have to be opened on your computer. DAT files can be opened with Line Sweep Tools or Hand Held Software Tools.  

 

Can the PSN50 be used on a PC?

No it can't. There is no Anritsu application for this power sensor and it can only be used with units that have option 19.

What is a Z540 calibration?

The Standard Service Program provides economic per-incident service for most Anritsu products at a pre-established standard price. All service is provided on a return to Anritsu service center basis. Two types of Z540-compliant calibration services are offered. Standard Calibration provides the minimum level of documentation necessary for compliance with ANSI/NCSL Z540-1-1994. For those customers who need a full set of pre- and post-calibration data, we offer Premium Calibration.

Can you tell me the difference between the 2000-767-R and the 2000-1618-R?

The only difference is the frequency range. The 2000-767 is DC to 4 GHz and the 2000-1618-R is DC to 6 GHz. There is also a female 7/16 Open/Short/Load part number 2000-768-R and 2000-1619-R. 2000-768-R frequency range is DC to 4GHz and 2000-1619-R is DC to 6GHz.

What happens if the battery of my site master is completely discharged?

If a battery is allowed to totally discharge, the smart-memory capability of the battery may be lost, resulting in incorrect battery capacity readings or loss of communication with the battery.

Is there any recommendation for Battery Life on a Site Master?

The NiMH battery will last longer and perform better if allowed to completely discharge before recharging. For maximum battery life, it is recommended that the NiMH battery be completely discharged and recharged once every three months.

Is there a rack mount kit available for handheld instruments?

There is a rack mount kit available for current models of handheld instruments. The part number is 66864. This kit can be used with the following models: S331E, S332E, S361E, S362E, MT8221B, MT8222B, MT8212E, MT8213E, S412E, MS2024B, MS2025B, MS2034B, MS2035B, MS2026C, MS2028C, MS2036C, MS2038C, MS2722C, MS2723C, MS2724C, MS2725C, MS2726C, MS2711E, MS2712E, MS2713E, and MS2721B

How do I copy files from my internal memory to my USB memory stick?

 

The steps below detail copying a file from internal memory to an external flash drive.

 

NOTE:

Select the files to copy in the top window and the location for the files to be copied to in the bottom window.

 

Insert a USB drive into either USB Type A port of the Site Master.

 

From the File main (shift/file (#7 key)) menu, press the “Copy (soft key)” submenu key. The Copy submenu and Copy dialog box are displayed (picture below).

 

Select the file(s) to copy. To select multiple files, highlight the first then press the “Select or De-Select” key to keep the file selected.  NOTE: (Press again to de-select if you choose not to copy the file.) The file will be outlined in blue. Repeat with all the files to copy. To display files in a folder, select the folder and press the Enter key.

 

Press the Scroll key and highlight the USB drive and press “select or de-select” soft key in the lower window using the touch screen or the Up/Down arrow keys or Thumb Wheel. NOTE: The Scroll submenu key toggles between Src (top window) and Dst (bottom window). Basically, the top window (src) is where you copy from and the bottom (dst) is where those files are going to.

 

Press the Copy key to copy the files to the flash drive.

 

 

 

NOTE:   If you want to check and see if those files have been copied, simply press the Scroll soft key (to get to your Src or source box), use your Up/Down arrows or Thumb Wheel to get to your USB Drive and press “Enter”. 

Where can I find information on how to erase my product's memory?

Please contact your Sales Representative or Technical Support at 1-800-ANRITSU (1-800-267-4878) for memory erasure /letter of volatility information.