Anritsu Signal Analyzers/Spectrum Analyzers

Solve all your measurement needs with Anritsu's wide line-up of signal and spectrum analyzers, ranging from high-performance and multi-function, high-end models for R&D to handheld types for field use.

Selection Guide pdf 2.9 MB 6/28/2019

Technical Note - The Basis of Spectrum Analyzers

Technical Note associated with MS266x, MS268x Series, MS8608A/09A.

Technical Note pdf 690.6 KB 12/20/2016

MS8608A/MS8609A Digital Mobile Radio Transmitter Tester

Technical Note for the MS8608A/MS8609A Digital Mobile Radio Transmitter Tester

Technical Note pdf 901.0 KB 12/5/2012

MS8608A/MS8609A Digital Mobile Radio Transmitter Tester (cdmaOne,cdma2000 1xRTT)

Product Introduction for the MS8608A/MS8609A Digital Mobile Radio Transmitter Tester (cdmaOne,cdma2000 1xRTT)

Product Introduction pdf 888.3 KB 12/5/2012

MS8609A Digital Mobile Radio Transmitter Tester

The MS8609A is a transmitter tester equipped with an internal spectrum analyzer, a modulation analyzer and a power meter.

Brochure pdf 4.0 MB 12/5/2012

MS8609A-32 Maximum Input Level Extension(For MS8609A) Operation Manual

The contents of this Operation Manual explain the operation of the MS8609A-32 Maximum Input Level Extension which is intended to expand the functions of the MS8609A Digital Mobile Radio Transmitter that comes with the MX860901A/MX860901B W-CDMA Measuring Software installed.

Operations Manual pdf 152.2 KB 4/17/2012

MX268130A/330A/730A/MX860830A/930A Wireless LAN Measurement Software (for MS2681A/MS2683A/MS2687A/MS2687B/MS8608A/MS8609A) Operation Manual

This operation manual provides the explanation of the MX268130A/MX268330A/MX268730A/MX860830A/MX860930A Software when it is installed in the MS2681A/MS2683A/MS2687A/MS2687B Spectrum Analyzer or MS8608A/MS8609A Digital Mobile Radio Transmitter Tester.

Operations Manual pdf 4.3 MB 4/17/2012

MX860803A/MX860903A/MX268103A/MX268303A/MX268703A cdma Measurement Software(For MS8608A/MS8609A/MS2681A/MS2683A/MS2687A/B) Operation Manual

The contents of this Operation Manual explain the operation of the MS8608A/09A Digital Mobile Radio Transmitter Tester and the MS2681A/83A/87A/B Spectrum Analyzer when the MX860803A/MX860903A/MX268103A/MX268303A/MX268703A cdma Measurement Software is installed.

Operations Manual pdf 3.2 MB 4/16/2012

MX860805A/MX860905A/MX268105A/MX268305A/MX268705A π/4 DQPSK Measurement Software (For MS8608A/MS8609A/MS2681A/MS2683A/MS2687A/B) Operation Manual

The contents of this Operation Manual explain the operation of the MS8608A/09A Digital Mobile Radio Transmitter Tester and the MS2681A/83A/87A/B Spectrum Analyzer when the MX860805A/MX860905A/MX268105A/MX268305A/MX268705A π/4 DQPSK Measurement Software is installed.

Operations Manual pdf 4.6 MB 4/16/2012

MX860903A cdma Measurement Software

MX860903A cdma Measurement Software is the application software used in the MS8609A Digital Mobile Radio Transmitter Tester.

Brochure pdf 468.1 KB 11/2/2006

MX860904A CDMA2000 1xEV-DO Measurement Software

MX860904A cdma Measurement Software is the application software used in the MS8609A Digital Mobile Radio Transmitter Tester.

Brochure pdf 451.2 KB 11/2/2006

MX268041B HSDPA Automatic Measurement Software

The MX268041B HSDPA Automatic Measurement Software brings simple automated Tx testing to HSDPA base stations by installing it in an external PC to control the MS8608A/MS8609A in which the dedicated MX860850A/MX860950A measurement software has been installed.

Brochure pdf 488.1 KB 7/26/2006

MX860805A/MX860905A PHS Measurement Software

Application Note MX860805A/MX860905A PHS Measurement Software

Application Note pdf 540.1 KB 5/17/2006

MX860803A/MX860903A cdma Measurement Software

Application Note for the MX860803A/MX860903A cdma Measurement Software

Application Note pdf 775.9 KB 5/17/2006

MX860802A/MX860902A GSM Measurement Software

Application Note for the MX860802A/MX860902A GSM Measurement Software

Application Note pdf 648.1 KB 5/17/2006

MX860805A PI/4DQPSK Measurement Software (for MS8608A Digital Mobile Radio Transmitter Tester)

The MX860805A application software is used with the MS8608A Digital Mobile Radio Transmitter Tester to evaluate transmission systems in conformance with the PDC, PHS, NADC (IS-136), STD-39/T79 and STD-T61 standards and general purpose.

Datasheet pdf 474.4 KB 6/16/2005

MX860905A PI/4DQPSK Measurement Software (for MS8609A Digital Mobile Radio Transmitter Tester)

The MX860905A application software is used with the MS8609A Digital Mobile Radio Transmitter Tester to evaluate transmission systems in conformance with the PDC, PHS, NADC (IS-136), STD-39/T79 and STD-T61 standards and general purpose.

Datasheet pdf 482.2 KB 6/16/2005

MX268160A/MX268360A/MX268760A - MX860860A/MX860960A TD-SCDMA Measurement Software

MX268160A/MX268360A/MX268760A (for MS2681A/MS2683A/MS2687B Spectrum Analyzers)-MX860860A/MX860960A (for MS8608A/MS8609A Digital Mobile Radio Transmitter Testers)TD-SCDMA Measurement Software

Datasheet pdf 544.7 KB 5/26/2005

MX860850A HSDPA Measurement Software (For MS8608A Digital Mobile Radio Transmitter Tester)

MX860850A HSDPA Measurement Software is the application software designed for MS8608A Digital Mobile Radio Transmitter Tester. The installation of MX860850A enables the evaluation of transmitter side conforming to HSDPA standards.

Datasheet pdf 630.0 KB 2/3/2005

MX860950A HSDPA Measurement Software (For MS8609A Digital Mobile Radio Transmitter Tester)

MX860950A HSDPA Measurement Software is the application software designed for MS8609A Digital Mobile Radio Transmitter Tester. The installation of MX860950A enables the evaluation of transmitter side conforming to HSDPA standards.

Datasheet pdf 631.6 KB 2/3/2005

By Document Type

MS8609A Core Module Software

Firmware for MS8609A (login, password is required.)

Drivers Software Downloads 12/1/2008

MX8609xx Measurement software

Measurement software for MS8609A (login, password is required.)

Drivers Software Downloads 11/17/2008

By Product Category

Is it possible to add option-08 Pre-amplifier to MS8609A?

If the MS8609A already has option-30 LPF for 2GHz band carrier installed, you can not add option-08. Otherwise, yes, the option can be installed.

On the MS8608A and MS8609A when they are fitted with the option 36 or 37 (6GHz power meter option), are the normal 3GHz specs the same as the 6GHz specs.? Or are the specs de-rated from 3 to 6GHz?

The power meter accuracy range with option 36 or 37 is from -20dBm to+20dBm and the accuracy is +/- 10% by 6GHz. The compensation data (3GHz to 6GHz) is writen for option 36 or 37. Option 36 and 37 are same function. Option 37 is to add the option after shipment.

MS8609A has option 30 which is LPF for carrier cut off in 2GHz band. Is this ootion built in or external What is the NLP1200 used for?

The option 30 is internal to the MS8609A. The NPL1200 is a HPF to measure spurious emissions less than 1 GHz band. By excluding a carrier in this LPF, the dynamic range can be raised.

What is the difference of MX860901A and MX860901B?

The following features were added to MX860901B. RACH measurement, Inner-loop measurement, Output power control of BTS measurement, Demodulation function, Compressed modemeasurement, APD measurement and Spurious wave-form display function.

Where is the power sensor used with the power meter in MS8609A? How do you do a calibration?

The power sensor is internal to the MS8609A. The calibration is performed by pressing the Power Calibration key.

In the MS8609A, can you read the Occupied Bandwidth waveform using GPIB?

The MS8609A can not read out the wave-form of Occupided bandwith over GP-IB.

While operating the MS8609A, "Over Range" was displayed in the screen. How is this message cleared?

This message is an error statement that the input level to the instrument is exceeding the refernce level. This error is very similar to the Under Range error. The way to erase this message is be either changing the reference level or by pressing the "Adjust Range" key. Optimization of the input is automatically done by this key and the error message display disappears.

Can Option-05 Rubidium reference oscillator be installed into an MS8609A with Option-01 (Precision frequency reference)?

It is possible that Option-01 and Option-05 are installed simultaneously. If you use option-05, please connect the 10MHz output of option-05 to the 10MHz reference input with a BNC cable.

Is it possible to add option-08 Pre-amplifier to MS8609A with option-30 ?

It is not possible to add option-08 to MS8609A with option-30.

In the MX860805A/MX860905A software, what is the difference of PI/4 DQSK and the PI/4 Shift QPSK?

PI/4 DQSK(Differential QPSK) and the PI/4 Shift QPSK are the same. PI/4 Shift QSK is used by such standards as ARIB STD-28(PHS) and PI/4 DQPSK is used by IS-136 (TDMA). Another difference is that the QPSK modulations has four symbols and DQPSK with Differential coding has eight symbols.