RF and Microwave Signal Generator MG3690C Product Brochure

The RF and Microwave signal generator series MG3690C covers the audio, HF, VHF, UHF, RF, and microwave frequencies and provides coverage from 0.1 Hz to 70 GHz with a single coaxial output (up to 500 GHz with external multipliers). With excellent phase noise, fast switching speeds, and a full suite of analog modulation capabilities (including high-performance pulse modulation), the MG3690C series is an optimal signal source solution for the design and testing of components and systems for a wide variety of industries. P/N: 11410-01119

Brochure pdf 1.5 MB Version: C 6/14/2022

MG369xC Series Synthesized Signal Generators Maintenance Manual

This manual provides service information for the Signal Generator MG369xC. The service information includes replaceable parts information, troubleshooting, performance verification tests, calibration procedures, functional circuit descriptions, block diagrams, and assembly/subassembly removal and replacement. P/N: 10370-10376

Maintenance Manual pdf 11.0 MB Version: R 5/3/2022

RF and Microwave Signal Generator MG369xC GPIB Programming Manual

This manual provides information for remote operation of the Series MG369xC Synthesized High Performance Signal Generator using commands sent from an external controller via the IEEE-488 General Purpose Interface Bus (GPIB). P/N: 10370-10374

Programming Manual pdf 3.2 MB Version: F 5/3/2022

RF and Microwave Signal Generator MG3690C Operation Manual

This manual provides general information, installation and operating information for the Anritsu series MG369xC synthesized signal generator. P/N: 10370-10373

Operations Manual pdf 7.7 MB Version: K 5/3/2022

RF and Microwave Signal Generator MG3690C Technical Data Sheet

The MG3690C is the ideal microwave signal generator, offering unsurpassed frequency coverage, the lowest phase noise, leveled output power, spectral purity, switching speed, modulation performance, size, upgradeability, reliability, and service. P/N: 11410-00515

Datasheet pdf 1.9 MB Version: W 5/3/2022

Interference Test of 5G/LTE User Equipment with Signal Generator and RF Signaling call box

This is a leaflet about the interference test of 5G/LTE User Equipment with signal generator and MT8000A/MT8821C

Leaflet pdf 218.1 KB 1/21/2022

Anritsu's RF and Microwave Test and Measurement Solutions Product Brochure

Overview of RF and Microwave instruments available to meet a variety of solutions. Featuring the frequency range, measurements, and other key features. P/N: 11410-00800

Brochure pdf 14.5 MB Version: AB 3/9/2021

Conducting Gain Compression Measurements Utilizing Peak Power Sensors Application Note

While complex communication signals can transmit information very efficiently, they exhibit large and random amplitude and power variations (commonly referred to peak to average power ration [PAPR] or crest factor). These complex signals are also not very tolerant to nonlinear distortion that inevitably occurs while they are processed by communication subsystems. To minimize the impact on the design and production of today's communications systems, this application note discusses robust measurement methods that can be used to help characterize and quantify the effect these nonlinearities will have on complex signals. P/N: 11410-01199

Application Note pdf 1.9 MB Version: A 7/14/2020

Option 10 - User-Defined Modulation Waveform Software for the MG3690 Series User Guide

This manual provides general information, a description of required equipment, setup procedures, operating instructions, and programming commands for Option 10. P/N: 10370-10327

User Guide pdf 1.8 MB Version: D 3/3/2020

RF and Microwave Signal Generator MG369xC SCPI Programming Manual

This manual provides information for remote operation of the Synthesized Signal Generator Series MG369xC using commands sent from an external controller via the IEEE-488 General Purpose Interface Bus (GPIB). P/N: 10370-10375

Programming Manual pdf 3.0 MB Version: E 3/3/2020

EU Declaration of Conformity for the Signal Generator MG3690C

This Declaration of Conformity is a special document issued by Anritsu to state that the product meets all of the applicable legislation and European directives. P/N: 10101-00067

Datasheet pdf 107.1 KB Version: A 6/21/2019

Broadband RF and Microwave Signal Generator MG3690C Quick Fact Sheet

This two page quick fact sheet covers the key specifications, phase noise and tracking, analog modulation, along with stable time base and power. P/N: 11410-01118

Brochure pdf 314.3 KB Version: A 3/27/2019

EU Declaration of Conformity for the Millimeter-Wave Source Multiplier Modules

The mmW Multiplier Declaration of Conformity is a special document issued by Anritsu to state that the product meets all of the applicable legislation and European directives. P/N: 10101-00020

Datasheet pdf 24.9 KB Version: A 6/9/2017

Radar Testing with Simulation Signals Application Note

This application note describes a process for simulating radar signals using an Anritsu Microwave Signal Generator, a Power Meter, a Power Sensor, and PowerMax Software. P/N: 11410-00752

Application Note pdf 1.8 MB Version: A 11/12/2013

By Document Type

MG3690 Series Drivers

This file contains drivers that can be used with Anritsu synthesizer signal generators. There are drivers applicable to the MG3690C Series (including MG3691C, MG3692C, MG3693C, MG3694C, MG3695C, MG3697C), the MG3690B Series (including MG3691B, MG3692B, MG3693B, MG3694B, MG3695B, MG3696B), and older models included in the MG3690A series, 68000B series, 68100B series, 68200B series, and 68300B series.

Drivers Software Downloads zip 23.6 MB Version: A 1/30/2013

Option 10 - User-Defined Modulation Waveform Software for the MG3690 Series

Drivers Software Downloads zip 5.7 MB 10/2/2006

By Product Category

I have a 69347B that someone put in Secure Mode Active. How do I get out of Secure Mode?

To return the 682XXB/683XXB to unsecured (normal) operation, press SYSTEM, then press Reset .

How long will Anritsu “fully” support the equipment after it has been discontinued?

We will support the equipment 7 years after its discontinuance date.   Pleasecall 800-Anritsu (267-4878) for that information.

We have a MG3692B that shows an option SM6260 on the back panel. We cannot find a description for this option. What is this option?

The SM6260 specialoffers enhanced pulse jitter performance (a.k.a. anti-jitter) in MG3690B signalgenerators with option 28 (or options 26x and 27) when using an externaltrigger. There is a Supplementary Data Sheet for thisoption that describes the option in more detail. Please contact Anritsu Technical Support ifyou would like to request this Supplementary Data Sheet. Signal Generator model number and serialnumber will need to be verified

We have a MG3692B that has option SM5815. We cannot find a description of this option.

SM5815 provides an external reference loop of the internal 100MHzreference signal, which can be used to tie two 69B or two MG3690A+3, twoMG3690B+3, two MG3690C with either option 3 or 3x units together or two MG3690Cwith SM6452, for phase tracking purposes. Two such instruments with common10MHz and 100MHz reference signals will have virtually no differential phasewander. Slight phase wander with respect to the 10MHz reference will stillexist, in the order of 5 degrees over 100 ms.There is a SupplementaryData Sheet for option SM5815 that describes the option in more detail. Please contact Anritsu Technical Support ifyou would like to request this Supplementary Data Sheet. Signal Generator model number and serialnumber will need to be verified.

How much does it cost for Repair and/or Calibration?

Look on the tool bar of  this website and hover your mouse over the “Services & Support” words on the toolbar and click on “Repair and Calibration”. Next, click on “Repair and Calibration Pricing”. Enter your model number. The result will show your model number as a hyper link (in blue). Click on it to see the pricing.

What is the maximum reverse RF power that can be reflected to the RF Output port of the 68147B? We cannot find this in the specifications.

This is not specified in the data sheet. The max reflected power the RF Output portcan handle is +30 dBm. This is the casefor all Anritsu Signal generators.

What temperature does the MG3690B/C series signal generator have to reach before it shuts down?

The maximum operating temperature is +50 degrees celsius. The units internal power supply has a temperature sensor which will open at some temperature above +50 degrees celsius and the unit will then perform a power down. If the temperature of the power supply sensor is lowered back to an operating temperature then it closes and the unit will turn back on.

Can the MG3692C send signals into loop antennas with signal input levels up to or close to +20 dBm?

The instrument will not be damaged by driving the antenna over the frequency range specified in the data sheet for the antenna. However, since the antenna does not present a 50 ohm load to the generator, the actual power delivered to the antenna will be different than that displayed on the front panel of the MG3692C. The user will need to somehow monitor the power to the antenna under the actual use conditions in order to accurately determine the power being delivered. The best way to do this would be to set the MG3692C power level to provide a given field strength from the antenna without regard to the numeric setting of the front panel level indicator on the MG3692C

What temperature does the MG3690B/C series signal generator have to reach before it shuts down?

The maximum operating temperature is +50 degrees celsius. The units internal power supply has a temperature sensor which will open at some temperature above +50 degrees celsius and the unit will then perform a power down. If the temperature of the power supply sensor is lowered back to an operating temperature then it closes and the unit will turn back on.

Where can I find information on how to erase my product's memory?

Please contact your Sales Representative or Technical Support at 1-800-ANRITSU (1-800-267-4878) for memory erasure /letter of volatility information.