I want to easily step from channel to channel using my MS2721B spectrum analyzer. How can I do that?
answer

In the frequency menu there is a soft key called "Freq Step".  It has a default value of 1 MHz.You can change that value to anything you want to a resolution of 1 Hz. Once you have that value set to your channel spacing, set the center frequency to your first channel. Then use the up and down arrows to move in the step size you entered. Make sure the center frequency is the active parameter before pressing the up or down arrow. You can also change a parameter you didn't intend. The Frequency step can also be used to change start frequency and stop frequency.