Skip to main content
Capsule Checkweigher

Capsule Pharmaceutical Checkweigher
This product has been discontinued
Anritsu capsule checkweighers weigh capsules at high speed and high accuracy.
Overview

Anritsu capsule checkweighers weigh capsules at high speed and high accuracy.

Industry-leading weighing performance enhances both production and research & development efforts.

Best weighing solution for capsules containing active pharmaceutical ingredients.

Slight variances in active pharmaceutical ingredients can have a large impact on a drug's efficacy. Anritsu's force balance weighing technology provides the industry's highest weight accuracy of +/-0.5 mg*, meeting even the most stringent standards for capsules containing high potency active pharmaceutical ingredients.

*Based on our survey results.
Force Balance Load Cell

Stable and reliable feeding of semi-locked capsules - Achieved!

Our unique capsule handling technology eliminates empty capsules from bouncing and provides stable feeding throughout the inspection process. Minimizing product vibration is critical for high accuracy weighing. Accurately weighing empty capsules can also improve the reliability of clinical trials and new drug testing.

Stable and reliable feeding of semi-locked capsules - Achieved!
Capsules in the magazine are fed by the shutter individually. The capsule holding unit minimizes any vibration generated from the impact of the drop from the magazine. The capsule is then fed onto the weigh table.

Every capsule in the system is monitored and tracked. Three rejection gates remove all defective products.

Every capsule in the system is monitored and tracked.

High precision weighing - made easy.

At a glance complete line monitoring.

Large touch paneI and user-friendly display offer simplified operation. Complete line status displayed on a single screen.

Large, intuitive touch screen GUI provides fast evaluation of production trends.
Displays histograms and trending information as well as underweight and overweight counts for each line, up to 10 lines at a time.

Large, intuitive touch screen GUI provides fast evaluation of production trends.

Designed within simplicity and safety in mind.

Tool-free parts removal
Tool-less changeover parts for capsules sizes 000 to 5.

Preventing changeover part errors
An alarm will alert the operator if a wrong or mismatched part is installed on the system.

Protection of weighcells
Overload protection mechanism protects the load cell from accidental overload during magazine changeover.

Quick and easy sensitivity confirmation
It only takes 30 seconds for the built-in weight check to verify weigh cell sensitivity. Time, effort and risk of making an error are greatly reduced compared to traditional verification procedures. Each weigh cell can be individually calibrated with the built-in weights.

Data security
Anritsu capsule checkweighers comply with FDA 21 CFR Part 11 standard for electronic records data compliance.

Changeover of magazineChangeover of magazine
There are two built-in verification weightsThere are two built-in verification weights available, 500 and 2,000 mg. The weight closest to the capsules in upper and lower limit weight values should be used for proper calibration.
$name

Anritsu capsule checkweighers weigh capsules at high speed and high accuracy.

Industry-leading weighing performance enhances both production and research & development efforts.

  • Maximum accuracy: +/-0.5 mg
External Dimensions

[Example model] KWS9001AP10: 10 lanes, Maximum throughput: 75,000 capsules/h

External Dimensions
Specifications
Model KWS9001AP10
Weighing range 2 to 2000 mg
Scale interval 0.1 mg
Maximum throughput1 75,000 capsules/h
Lane 10 lanes
Maximum accuracy (3σ)1 +/-0.5 mg
Display 15-inch color LCD
Operation method Touch panel + Key (Start, Stop, and Home are direct push buttons)
Indication range 2045.0 mg
Preset memory Maximum 50
Classification2 4 ways (overweight/correct weight/underweight/unclassified)
Product size Capsule No. 000 to 5
Power requirements3 100 Vac to 115 Vac +10% -15%, single phase, 50/60 Hz, rush current 74 A (typ) (90 ms or less)
Power consumption 550 VA
Air requirements 0.3 to 0.9 Mpa, Air supply port: nylon tube of 8 mm dia.
Mass 350 kg
Environmental conditions 15°C to 30°C (variation not to exceed 1°C/h to maintain accuracy), relative humidity 30% to 70% (non-condencing)
Protection class IP30 (IP50 for weighcell)
Exterior Stainless steel (SUS304)
Data output USB port (USB 2.0)
1: Maximum throughput and maximum accuracy may vary depending on capsule size, filling content and quantity.
2: A rejection gate is installed per 10 lanes.
3: 120 Vac, 200 Vac to 240 Vac are available as an option.
Note: The noise level of the checkweigher is 78 dB(A) or less.
Detection Areas

For details of detection areas, please submit an online inquiry form.

Model Lane Maximum throughput
KWS9001AP10 10 lanes 7.5 capsules/h
KWS9001AP20 20 lanes 15 capsules/h
Library