Skip to main content

Download Center

Search by product Model Number

By Document Type

Installation, Maintenance and Optimization Solutions Leaflet

A small 2 page flyer to showcase the right tools needed to achieve best in class network reliability. P/N: 11410-00855

Leaflet pdf 1.7 MB Version: F 29/07/2019

Installation, Maintenance and Optimization Solutions Brochure

Discover Anritsu's best-in-class tools which will help your technicians and engineers optimize all areas of your network and elevate your network reliability to best-in-class. P/N: 11410-00617

Brochure pdf 1.6 MB Version: F 16/07/2019

C-RAN Solutions Brochure

Transport, Optical & RF Testing for all Elements of the C-RAN Network. Anritsu has a long history of testing all aspects of the C-RAN. Our instruments evolve to meet the new challenges of testing the C-RAN networks being rolled out today. Put our experience to work for you!

Brochure pdf 3.2 MB Version: B 29/03/2018

Understanding IBW In-Building Wireless: DAS to Small Cells Application Note

The purpose of an in-building wireless (IBW) system is to provide enhanced network coverage and/or capacity when the existing macro network is not able to adequately service the demand. Coverage may be poor due to high penetration losses caused by the building structure or due to low emissivity glass installed to improve the thermal performance of the building. In dense urban environments, adjacent buildings may create an RF barrier that blocks coverage from nearby macro sites. Tall buildings typically have poor coverage on upper floors since macro site antennas, many floors below, are specifically designed to suppress energy radiating above the horizon. Capacity may be an issue in venues such as stadiums, coliseums and convention centers where many thousands of users may be trying to simultaneously access the network.

Application Note pdf 1.8 MB Version: C 28/03/2018

ACCESS Master MT9083 Series

Technicians maintaining diverse systems are forced to carry a large variety of test equipment on-site, including OTDRs, Light Sources, Optical Power Meters, Visible Light Sources, etc., as well as a notebook computer for evaluating the FTTx QoS. On the other hand, fiber construction requires measuring instruments with different functions and performance.In addition, core and backbone networks utilize long fibers while optical access networks use short fibers, both requiring different types of measuring instruments with different performance.But now Anritsu's new line of MT9083 ACCESS Master OTDRs solves all these problems by providing all the measurement functions and performance required for optical fiber construction and maintenance in a compact, lightweight, all-in-one unit that eliminates the burden of carrying many different test sets and instruments on-site.

Brochure pdf 2.1 MB 15/02/2018

MX900030A Connector Master Operation Manual

The MX900030A Connector Master is the software to observe, analyze, and make a pass-fail judgment of the fiber optic connector endface by personal computer using the G0306A Video Inspection Probe.

Operations Manual pdf 647.3 KB Version: Fourth 01/06/2017

Why do I need to inspect and/or clean the fiber in an optical BBU/RRH link?

After ruling out traditional problems like passive intermodulation (PIM), poorly aimed antennas and/or other coaxial problems, dirty fiber connectors account for 60 to 75% of the alarms, failures, and poor throughput problems found in modern cellular systems today.

Application Note pdf 2.4 MB Version: A 13/12/2016

MT9083 Series ACCESS Master Remote Control Operation Manual

The remote control function sends commands via the communications interface from the remote control PC to set the measuring instrument and read the measurement results and measuring instrument conditions.

Operations Manual pdf 1.2 MB Version: 4th 30/09/2016

MT9083 Series ACCESS Master Operation Manual

The MT9083 Series ACCESS Master Optical Time Domain Reflectometer (OTDR) reduces the time to install, commission and maintain fiber spans via high performance hardware and easy-to-use software.

Operations Manual pdf 8.1 MB Version: 20th 30/09/2016

USB 400x Video Inspection Probe G0306B

Scratches and stains to optic fiber ferrule endfaces are often said to have a negative impact on transmission quality. The Video Inspection Probe G0306B can be connected to the Network Master MT1000A/MT1100A Series, the ACCESS Master MT9083x2 Series, uOTDR MT9090A Series product and PC, to show the state of a ferrule endface. This function is effective for determining whether a ferrule endface is clean, and whether connector replacement is necessary due to connector scratches.

Product Introduction pdf 1.7 MB 15/04/2016

Video Inspection Probe G0306B

Scratches and stains to optic fiber ferrule endfaces are often said to have a negative impact on transmission quality. The Video Inspection Probe G0306B can be connected to the Network Master MT1000A/MT1100A Series, the ACCESS Master MT9083x2 Series, uOTDR MT9090A Series product and PC, to show the state of a ferrule endface. This function is effective for determining whether a ferrule endface is clean, and whether connector replacement is necessary due to connector scratches.

Leaflet pdf 1.1 MB 15/04/2016

Testing Distributed Antenna Systems (DAS) Application Note

DAS can encompass Fiber Optic Cables, RF Cables, Fiber Optic (PON) Splitters, RF Splitters, Radiating Cables, Amplifiers and all of these components can be in one single system. Each system will be as unique as the facility to which it will be installed. There is no simple "one size fits all" solution to testing a DAS, but if you break it down, it can be effectively tested and troubleshot. This application note breaks down these various types of components. P/N: 11410-00887

Application Note pdf 4.9 MB Version: A 02/11/2015

Fiber Visualizer Enhancements

"Fiber Visualizer" is a new fault location function designed to simplify the entire testing process. Fiber Visualizer automatically selects the testing parameters to ensure the correct setup and provides a simple, graphical summary of the fiber under test within seconds. A comprehensive PDF report can then be customized and generated, completing the testing process. Recent enhancements provide better event detection and accuracy as well as individualized PASS/FAIL analysis to simplify your FTTx/PON testing.

Leaflet pdf 386.6 KB 09/04/2015

USB 400x Video Inspection Probe G0306A

Scratches and stains to optic fiber ferrule endfaces are often said to have a negative impact on transmission quality. The Video Inspection Probe G0306A can be connected to the Network Master MT1000A/MT1100A Series, the ACCESS Master MT9083x2 Series, uOTDR MT9090A Series product and PC, to show the state of a ferrule endface. This function is effective for determining whether a ferrule endface is clean, and whether connector replacement is necessary due to connector scratches.

Product Introduction pdf 1.4 MB 28/05/2014

OPTION-545VIP USB 200/400x Video Inspection Probe

Scratches and stains to optic fiber ferrule endfaces are often said to have a negative impact on transmission quality. The OPTION-545VIP can be connected to an MT908x Series ACCESS Master, MT9090A Network Master Series product and PC, to show the state of a ferrule endface. This function is effective for determining whether a ferrule endface is clean, and whether connector replacement is necessary due to connector scratches.

Product Introduction pdf 1.5 MB 24/03/2014

Fiber Visualizer

“Fiber Visualizer” is a new fault location function designed to simplify the entire testing process. Fiber Visualizer automatically selects the testing parameters to ensure the correct setup and provides a simple graphical summary of the fiber under test within seconds. A comprehensive PDF report can then be customized and generated, completing the testing process.

Leaflet pdf 508.8 KB 28/05/2013

MX900021A Remote Screen Software Operation Manual

The MX900021A screen display software is software to display the MT9083 Series ACCESS Master screens to a personal computer via USB.

Operations Manual pdf 1.6 MB 23/04/2013

MT9083A2/B2/C2 ACCESS Master

Anritsu is now pleased to announce the enhanced MT9083A2/MT9083B2/MT9083C2 models. The ACCESS Master MT9083x2 now features a 7-inch widescreen TFT-LCD display for use both indoors and outdoors, enhanced battery operation time (up to 12 hours), increased operating temperature range (-10 to 50 oC) and new short-cut function keys.

Leaflet pdf 283.8 KB 24/08/2012

By Document Type

MX9083x2_Firmware_v211_E

Firmware and documents for MT9083x2 are contained in the zip file.

MD5 : 2c7c5ed223acfd4741667318594449e9

Drivers, Software Downloads zip 37.5 MB Version: 2.11 11/04/2019

Previous Version Firmware for MX9083x2

Previous Version Firmware and documents for MT9083x2 are contained in the zip file.

MD5 : 22610480dc05a8c44528cc6ac785279e

Drivers, Software Downloads zip 37.4 MB Version: 2.10 04/10/2018

MX900030A_Connector Master_v104_E

Software and documents for MX900030A Connector Master are contained in the zip file.

MD5 : 9e3b1b0c670025de778872e8bc09f15a

Drivers, Software Downloads zip 43.1 MB Version: 1.04 01/06/2017

MX9083_v548_E

The following Firmware and documents for MT9083x/MT9083x1 are contained in the zip file (v5.48).

MD5 : aba428f7d2e8b4018ea61f9926f773a8

Drivers, Software Downloads zip 8.8 MB Version: 5.48 15/09/2016

MT9083Series_RemoteScreenSoftware_MX900021A_v101_E

The following Software for MT9083 series are contained in the zip file.

Drivers, Software Downloads zip 52.7 KB Version: 1.01 28/06/2012

By Product Category

No Records Found
Confirm your country below to see local events, contact information and special offers.