Skip to main content

Optical Spectrum Analyzer

MS9710C
Поддержка этого продукта прекращена Варианты замены: MS9740A
Overview

The MS9710C provides excellent wavelength accuracy, waveform shape, and new features. This Optical Spectrum Analyzer (OSA) is an improved version of the popular MS9710B and features improved wavelength accuracy, resolution bandwidth, and signal-to-noise averaging. This diffraction grating spectrum analyzer covers a wide wavelength range from 600 to 1750 nm. The MS9710C features high power level accuracy, wide dynamic range, and high reception sensitivity.

MS9710C has been enhanced with much better performance in the L-Band region between 1570 nm and 1620 nm. The enhancement is an option (MS9710C-15) so customers who do not require absolute accuracy for L-Band measurement need not pay for it.

 

MS9710B

MS9710C

MS9710C-15

Main features

C-band
Up to 100 GHz channel spacing

C+L Band
Up to 50 GHz channel spacing

 

Measurement range

600-1750 nm

Wireless accuracy

50pm(1530-1570 nm)

20 pm(1530-1570 nm)

50 pm (1520-1600 nm)

20 pm

(1520-1620 nm)

MAX. RBW

70 pm

50 pm

RBW accuracy
 (0.2 nm)

<3% (1530-1570 nm)

<3% (1530-1570 nm)

<3%  (1520-1620 nm)

Level flatness

+/-0.1 dB

(1530-1570 nm)

 

+/-0.1 dB

(1530-1570 nm)

+/-0.3 dB

(1520-1620 nm)

+/-0.1 dB

(1520-1620 nm)

PDL

+/- 0.05 dB (C-band)

+/- 0.05 dB (C +L band)

Level linearity

+/- 0.05 dB (C-band)

+/- 0.05 dB (C +L band)

  • Improved signal-to-noise measurement with left and right noise floor averaging
  • Tracking function with tunable laser source
  • Built-in attenuator for high power optical input
  • Optional built-in light source and reference wavelength
  • VGA output connector

Specificiations
  • Overview
    The MS9710C can measure wavelength, power level, and SNR for up to 300 DWDM channels. It can also be used for PMD and EDFA noise floor measurements.

  • Tunable Laser Source Tracking
    This internal function eliminates the need for an external controller to make measurements using an Anritsu TLS.

  • Internal Light Sources
    Optional SLD, white light, and reference wavelength light sources can be installed in the MS9710C to simplify measurements. Calibration with the built-in reference source is a one-button operation.

  • L-Band Measurements
    Option 15 improves wavelength ccuracy, resolution, power level flatness, and linearity in the 1570 to 1620 nm L-band region.

Библиотека