Skip to main content
MENU
Microwave Detectors 5400-71/560-7 Series

Microwave Detectors

5400-71/560-7 Series
この製品は製造中止となっております。
概要

The Anritsu 560-7 and 5400-71 Series RF Detectors are used with the Model 56100A Scalar Network Analyzer and with Series 54100A Scalar Measurement System for making coaxial transmission loss or gain and power measurements. They are also used with the Site MasterR and Cable MateR Series Personal SWR/RL and Fault Location Testers for making power measurements.

  • Zero-biased Schottky diodes
  • -55 dBm to +16 dBm range
Disc. Models

 Model

 Frequency Range

 Impedance

 Return Loss

 Input Connector

 Frequency Response

560-7A50

0.01 to 18 GHz 

 50 Ohms

15 dB, <0.04 GHz
22 dB, <8 GHz
17 dB, <18 GHz

 GPC-7

±0.5 dB, <18 GHz

560-7N50B

0.01 to 20 GHz

 50 Ohms

15 dB, <0.04 GHz
22 dB, <8 GHz
17 dB, <18 GHz
14 dB, <20 GHz 

 N(m)

±0.5 dB, <18 GHz
±1.25 dB, <20 GHz

560-7S50B

0.01 to 20 GHz

 50 Ohms

 15 dB, <0.04 GHz
22 dB, <8 GHz
17 dB, <18 GHz
14 dB, <20 GHz

 WSMA(m)

±0.5 dB, <18 GHz
±1.25 dB, <20 GHz

560-7S50-2

0.01 to 26.5 GHz

 50 Ohms

15 dB, <0.04 GHz
22 dB, <8 GHz
17 dB, <18 GHz
14 dB, <26.5 GHz

 WSMA(m)

±0.5 dB, <18 GHz
±1.25 dB, <26.5 GHz

560-7K50

0.01 to 40 GHz

 50 Ohms

12 dB, <0.04 GHz
22 dB, <8 GHz
17 dB, <18 GHz
15 dB, <26.5 GHz
14 dB, <32 GHz
13 dB, <40 GHz

K(m)

±0.5 dB, <18 GHz
±1.25 dB, <26.5 GHz
±2.2 dB, <32 GHz
±2.5 dB, <40 GHz

5400-71B50

0.001 to 1.5 GHz

50 Ohms

20 dB

BNC(m)

±0.2 dB, <1.5 GHz

5400-71B75

0.001 to 1.5 GHz

75 Ohms

20 dB

 BNC(m)

±0.2 dB, <1.5 GHz

5400-71N50

0.001 to 3 GHz

 50 Ohms

26 dB

 N(m)

±0.2 dB, <1 GHz
±0.3 dB, <3 GHz

5400-71N75

0.001 to 3 GHz

75 Ohms

26 dB, <2 GHz
20 dB, <3 GHz

 N(m)

±0.2 dB, <2 GHz
±0.3 dB, <3 GHz

5400-71N75L**

0.001 to 3 GHz

75 Ohms

24 dB

 N(m)

±0.2 dB, <1 GHz
±0.5 dB, <1.2 GHz

* The maximum input power is +20 dBm for all microwave detectors with the exception of 5400-71N75L.
**The input of the 5400-71N75L is designed to extend the damage level to IW (+30 dBm).
Compression begins at 10 dBm <0.05 GHz, 15 dBm <1 GHz, or 20 dBm <1.2 GHz.

Specifications

 Model

 Frequency Range

 Impedance

 Return Loss

 Input Connector

 Frequency Response

560-7VA50

0.01 to 50 GHz

50 Ohms

15 dB, <0.04 GHz
19 dB, <20 GHz
15 dB, <40 GHz
10 dB, <50 GHz

 V(m)

±0.8 dB, <20 GHz
±2.5 dB, <40 GHz
±3.0 dB, <50 GHz

* The maximum input power is +20 dBm for all microwave detectors with the exception of 5400-71N75L.
Compression begins at 10 dBm <0.05 GHz, 15 dBm <1 GHz, or 20 dBm <1.2 GHz.