Skip to main content
5400-6 Series SWR Autotesters

SWR Autotesters

5400-6 Series
This product has been discontinued
Overview

The 5400-6 Series SWR Autotesters integrate a high directivity bridge, a detector, a low reflection test port, a precision reference termination, and a connecting cable. They are used with the Model 56100A Scalar Network Analyzers and with Series 54100A Scalar Measurement Systems for making fixed-frequency and swept-frequency return loss (SWR) measurements. Return loss measurements are used over a wide range of radio and microwave frequencies to check the performance of systems, subsystems, and microwave components such as amplifiers, directional couplers, attenuators, filters, splitters, and terminations.

  • 40 dB directivity.
  • 1 MHz to 3000 MHz range
  • F, N, or BNC type test port connectors
Applications

 Model

 Directivity (dB)

 Accuracy1

 Test Port Connection

 Physical

5400-67FF752,5

 40

10-1000 MHz

 F(f)

 

0.010 ±0.01p2

5400-6B50B3
5400-6BF50B3

 40

1-1500 MHz

BNC (m)
BNC (f)

 Dimensions: 2.5 x 5.1 x 7.0 cm

Weight: 225g

0.010 ±0.01p2

5400-6B75B3,5
5400-6BF75B3,5

40

0.010 ±0.10p2

BNC (m)
BNC (f)

5400-6N503
5400-6NF503

40

1-1000 MHz

100-3000 MHz

2000-3000 MHz

Type N (m)
Type N (f)

0.010 ±0.05p2

0.010 ±0.05p2

0.010 ±0.05p2

5400-6N753,5
5400-6NF753,5

40

0.010 ±0.05p2

0.010 ±0.05p2

0.010 ±0.05p2

Type N (m)
Type N (f)

1 Where p is the reflection coefficient being measure. Accuracy includes the effects of test port reflections and directivity.
2 Input Connector: BNC Female
3 Input Connector: Type N Female
4 Plus connectors and cable
5 Impedance 75 Ohms

  Input Port Impedance:   50 Ohms (except as noted)
  Insertion Loss (from input to test port):   6.5 dB nominal
  Detector Output Polarity:   Negative
  Output time Constant:   2 ms
  Maximum Power Input:   0.5 watts (+27 dBm)
  Cable Length:   122 cm (4 ft.)
  Temperature Range:   +25 °C ±5 °C

Library