Spectrum Analyzer/Signal Analyzer MS2830A Microwave

 
Spectrum Analyzer/Signal Analyzer MS2830A Microwave
Features
  • 9 kHz to 26.5/43 GHz frequency range; 43 GHz max. built-in pre-amp option
  • Best-of-class wide dynamic range over 6 GHz
  • 110 GHz max. frequency range; built-in 1st local signal output for external mixer
  • For wideband down-converter; built-in 1 GHz IF output band
  • 10/31.25/62.5/125 MHz analysis bandwidth options (signal analyzer and modulation analysis functions)
  • Supports Noise Figure and BER measurement (options)
  • Excellent eco-friendly product with low power consumption of 190 VA min.

The MS2830A-044/045 Signal Analyzer includes a spectrum analyzer function for measuring up to 110 GHz using an external mixer based on the 26.5 GHz/43 GHz upper frequency limit. It supports measurements of Tx characteristics, including adjacent channel leakage power, spectrum mask, and frequency counter, as well as spurious measurements requiring a wide dynamic range.


Installing the 10/31.25/62.5/125 MHz analysis bandwidth option adds signal analyzer functions for checking phenomena that are hard to check using a spectrum analyzer, such as frequency vs. time, phase vs. time, spectrogram, and CCDF. In addition, optional measurement software supports modulation analysis. Moreover, installing a preselector bypass option enables use of the signal analyzer and modulation analysis functions up to 26.5 GHz/43 GHz (MS2830A-044/045). Finally, it can be customized to support a range of application-specific measurements.

  • Installing a microwave-band preamp supports measurement of weaker signals.
  • Using the 1st local signal output as an external mixer supports measurement of high-frequency signals up to 110 GHz.
  • Using the 1st IF signal output as a down converter supports analysis in combination with external equipment.


■ Key Performance

  • Frequency Range: MS2830A-044: 9 kHz to 26.5 GHz
                                      MS2830A-045: 9 kHz to 43 GHz
  • Best-of-class wide dynamic range over 6 GHz
        159 dB (at 25 GHz): TOI: ≥+13 dBm, DANL: −146 dBm/Hz
        157 dB (nominal, at 40 GHz): TOI: ≥+13 dBm nominal, DANL: −144 dBm/Hz
  • Preamp up to 43 GHz ⇒ Opt. 068/168: Microwave Preamplifier
    • DANL: −156dBm/Hz (at 25GHz)
    • DANL: −150dBm/Hz (at 40GHz)
  • Measures up to 110 GHz using External Mixer ⇒ Built-in connector to connect external mixer (MS2830A-044/045)
    • Frequency Range: 26.5 GHz to 110 GHz
    • Connector: SMA-J, 50 Ω
    • Local Signal Output: 5 GHz to 10 GHz
    • IF Signal Frequency: 1875 MHz
  • Used as Wideband Down Converter ⇒ Built-in IF Output Function (MS2830A-044/045)
    • Connector: SMA-J, 50 Ω
    • IF Output Frequency: 1875 MHz
    • IF Output Bandwidth: 1 GHz (3 dB Bandwidth, nominal)
    • Gain: −10 dB (nominal)
  • 10/31.25/625/125 MHz analysis bandwidth options (signal analyzer and modulation analysis functions)
        Opt.006: Analysis Bandwidth 10 MHz (20 MHz max. sampling rate = 50 ns resolution)
        Opt.005: Analysis Bandwidth Extension to 31.25 MHz (50 MHz max. sampling rate = 20 ns resolution) [MS2830A-044]
        Opt.009: Bandwidth Extension to 31.25 MHz for Millimeter-wave (50 MHz max. sampling rate = 20 ns resolution) [MS2830A-045]
        Opt.077: Analysis Bandwidth Extension to 62.5 MHz (100 MHz max. sampling rate = 10 ns resolution)
        Opt.078: Analysis Bandwidth Extension to 125 MHz (200 MHz max. sampling rate = 5 ns resolution)

        Note: An image response is received when setting the bandwidth to more than 31.25 MHz.
                   This can be used when not inputting a signal frequency outside the MS2830A analysis bandwidth (125 MHz max.).
                   The MS2690A/91A/92A Signal Analyzer series is recommended for other measurement purposes.
  • Excellent eco-friendly product with low power consumption of 190 VA min.
        MS2830A-044/045: 190VA (nominal)

 

 Application  Model No.  Name/Functions  Brochure  Product Introduction
 Spectrum Analyzer  MS2830A-044
 MS2830A-045
 26.5 GHz Signal Analyzer
 43 GHz Signal Analyzer
 Download  Download
 Signal Analyzer  MS2830A-005

 MS2830A-006
 MS2830A-009

 MS2830A-077

 MS2830A-078

 Analysis Bandwidth Extension to 31.25 MHz
 (Requires opt.006)
 Analysis Bandwidth 10 MHz
 Bandwidth Extension to 31.25 MHz for Millimeter-wave
(Requires opt.006, for MS2830A-045)
 Analysis Bandwidth Extension to 62.5 MHz
(Requires opt.006,005/009)
 Analysis Bandwidth Extension to 125 MHz
(Requires opt.006,005/009,077)
 3GPP LTE (FDD)  MX269020A  LTE Downlink Measurement Software  Download  Download
 MX269020A-001  LTE-Advanced FDD Downlink Measurement Software  
 MX269021A  LTE Uplink Measurement Software  Download
 3GPP LTE (TDD)  MX269022A  LTE TDD Downlink Measurement Software  Download
 MX269022A-001  LTE-Advanced TDD Downlink Measurement Software  
 MX269023A  LTE TDD Uplink Measurement Software  Download
 WLAN  MX269028A  WLAN (802.11) Measurement Software  Download
 MX269028A-001  802.11ac (80 MHz) Measurement Software  
 WLAN/Bluetooth  MX283027A-001  WLAN Test Software  Download
 MX283027A-002  Bluetooth Test Software
 W-CDMA/HSPA/HSPA
 Evolution Base station
 MX269011A  W-CDMA/HSPA Downlink Measurement Software  Download
 W-CDMA/HSPA/HSPA
 Evolution Mobile terminal
 MX269012A  W-CDMA/HSPA Uplink Measurement Software  Download
 W-CDMA  MX269030A  W-CDMA BS Measurement Software  
 GSM/EDGE  MX269013A  GSM/EDGE Measurement Software  Download
 MX269013A-001  EDGE Evolution Measurement Software
 TD-SCDMA  MX269015A  TD-SCDMA Measurement Software  
 TDMA type  MX269017A  Vector Modulation Analysis Software  Download
 CDMA2000 Base station  MX269024A  CDMA2000 Forward Link Measurement Software  Download
 MX269024A-001  All Measure Function   NEW
 1xEV-DO Base station  MX269026A  EV-DO Forward Link Measurement Software
 MX269026A-001  All Measure Function   NEW
 Noise Figure Measurement  MS2830A-017  Noise Figure Measurement Function  Download  Download
 BER Measurement  MS2830A-026  BER Measurement Function

Basic Performance

Items Specifications
 Frequency  Frequency range  9 kHz to 26.5 GHz (MS2830A-044)
 9 kHz to 43 GHz (MS2830A-045)
 SSB phase noise
 (500 MHz)
 +18º to +28ºC
 -115 dBc/Hz (100 kHz offset)
 -133 dBc/Hz (1 MHz offset)
 General  Dimensions and mass  426 (W)× 177 (H)× 390 (D) mm (Exclusive of surface projection)
 ≤15 kg (excluding other options)

 

Spectrum Analyzer

Items Specifications
  Frequency  Resolution bandwidth
 (RBW)
 Setting range: 1 Hz to 3 MHz (1-3 sequence), 50 kHz, 5 MHz, 10 MHz,
                           20 MHz*, 31.25 MHz*
 *: Can be set when with MS2830A-005, Can not be set when with MS2830A-009.
 Resolution bandwidth
 (CISPR RBW)
 with MS2830A-016
 Setting range: 200 Hz (6 dB), 9 kHz (6 dB), 120 kHz (6 dB),
                           1 MHz (Impulse)
  Amplitude  Displayed average
 noise level (DANL)
 +18º to +28ºC
 Detector: Sample, VBW: 1 Hz (Video average), Input attenuator: 0 dB
 without MS2830A-067/068, Frequency band mode: Normal
 −134 dBm/Hz (100 kHz)
 −144 dBm/Hz (1 MHz)
 −153 dBm/Hz (30 MHz ≤ f < 1 GHz)
 −150 dBm/Hz (1 GHz ≤ f < 2.4 GHz)
 −147 dBm/Hz (2.4 GHz ≤ f ≤ 3.5 GHz)
 −144 dBm/Hz (3.5 GHz < f ≤ 4 GHz)
 −144 dBm/Hz (4 GHz < f ≤ 6 GHz)
 −147 dBm/Hz (6 GHz < f ≤ 13.5 GHz)
 −145 dBm/Hz (13.5 GHz < f ≤ 18.3 GHz)
 −141 dBm/Hz (18.3 GHz < f ≤ 26.5 GHz)
 −141 dBm/Hz (26.5 GHz < f ≤ 34 GHz)
 −135 dBm/Hz (34 GHz < f ≤ 40 GHz)
 −132 dBm/Hz (40 GHz < f ≤ 43 GHz)
 Total absolute
 amplitude accuracy
 +18º to +28ºC
 ±0.5 dB   (300 kHz ≤ f < 4 GHz, Frequency band mode: Normall)
                 (300 kHz ≤ f < 3.5 GHz, Frequency band mode: Spurious)
 ±1.8 dB  (4 GHz ≤ f ≤ 13.8 GHz, Frequency band mode: Normal)
                 (3.5 GHz ≤ f ≤ 13.8 GHz, Frequency band mode: Spurious)
 ±3.0 dB (13.8 GHz < f ≤ 26.5 GHz)
 ±3.0 dB (26.5 GHz < f ≤ 40 GHz)
 ±3.5 dB (nominal, 40 GHz < f ≤ 43 GHz)
 Spurious responses  2-tone 3rd-order
 intermodulation
 distortion
 +18º to +28ºC, ≥300 kHz separation
 without MS2830A-068, or Preamp: Off,
 Mixer input level: −15 dBm (1wave)
 TOI = +12 dBm (30 MHz ≤ f < 300 MHz)
 TOI = +15 dBm (300 MHz ≤ f < 3.5 GHz)
 TOI = +14 dBm (3.5 GHz ≤ f ≤ 6 GHz, Frequency band mode: Normal)
 TOI = +13 dBm (6 GHz < f ≤ 13.5 GHz)
 TOI = +13 dBm (13.5 GHz < f ≤ 26.5 GHz)
 TOI = +13 dBm (nominal, 26.5 GHz < f ≤ 40 GHz)

 

Vector Signal Analysis (VSA) Function

Items Specifications
 General  Trace mode  Spectrum, Power vs. Time, Frequency vs. Time, Phase vs. Time, CCDF,
 Spectrogram, No Trace
 Analysis bandwidth  1 kHz to 10 MHz (1-2.5-5 sequence) (with MS2830A-006)
 1 kHz to 25 MHz (1-2.5-5 sequence), 31.25 MHz (with MS2830A-005,
 or with MS2830A-009)
 1 kHz to 25 MHz (1-2.5-5 sequence), 31.25 MHz, 50 MHz, 62.5 MHz [with MS2830A-077]
 1 kHz to 25 MHz (1-2.5-5 sequence), 31.25 MHz, 50 MHz, 62.5 MHz, 100 MHz, 125 MHz
    [with MS2830A-078]
 Note: An image response is received when setting the bandwidth to more than
           31.25 MHz.
           This can be used when not inputting a signal frequency outside the MS2830A
           analysis bandwidth (125 MHz max.).
           The MS2690A/91A/92A Signal Analyzer series is recommended for other
           measurement purposes.
 Sampling rate  2 kHz to 20 MHz (1-2-5 sequence) (with MS2830A-006)
 2 kHz to 50 MHz (1-2-5 sequence) (with MS2830A-005, or with MS2830A-009)
 2 kHz to 100 MHz (1-2-5 sequence) [with MS2830A-077]
 2 kHz to 200 MHz (1-2-5 sequence) [with MS2830A-078]
 Maximum capture time   0.5 s to 2000 s (determined according to analysis bandwidth)
 Spectrum
 displayed
 function
 Resolution bandwidth
 (RBW)
 Setting range: 1 Hz to 1 MHz (1-3 sequence)
                           [without MS2830A-077/078, or ≤31.25 MHz bandwidth]
 Setting range: 1 Hz to 3 MHz (1-3 sequence)
                           [with MS2830A-077, >31.25 MHz bandwidth]
 Setting range: 1 Hz to 10 MHz (1-3 sequence)
                           [with MS2830A-078, >31.25 MHz bandwidth]
 Displayed average
 noise level (DANL)
 without MS2830A-067/068, Frequency band mode: Normal
 −131.5 dBm/Hz (100 kHz)
 −141.5 dBm/Hz (1 MHz)
 −150.5 dBm/Hz (30 MHz ≤ f < 1 GHz)
 −147.5 dBm/Hz (1 GHz ≤ f < 2.4 GHz)
 −144.5 dBm/Hz (2.4 GHz ≤ f ≤ 3.5 GHz)
 −141.5 dBm/Hz (3.5 GHz < f ≤ 4 GHz)
 −141.5 dBm/Hz (4 GHz < f ≤ 6 GHz)
 −148.5 dBm/Hz (6 GHz < f ≤ 13.5 GHz)
 −146.5 dBm/Hz (13.5 GHz < f ≤ 18.3 GHz)
 −143.5 dBm/Hz (18.3 GHz < f ≤ 26.5 GHz)
 −143.5 dBm/Hz (26.5 GHz < f ≤ 34 GHz)
 −141.5 dBm/Hz (34 GHz < f ≤ 40 GHz)
 −137.5 dBm/Hz (40 GHz < f ≤ 43 GHz)
 Total absolute
 amplitude accuracy
 +18º to +28ºC
 without MS2830A-068, or Preamp: Off
 ±0.5 dB (300 kHz ≤ f < 4 GHz, Frequency band mode: Normal)
                (300 kHz ≤ f < 3.5 GHz, Frequency band mode: Spurious)
 ±1.8 dB (4 GHz ≤ f ≤ 13.8 GHz, Frequency band mode: Normal)
                (3.5 GHz ≤ f ≤ 13.8 GHz, Frequency band mode: Spurious)
 ±3.0 dB (13.8 GHz < f ≤ 26.5 GHz)
 ±3.0 dB (26.5 GHz < f ≤ 40 GHz)
 ±3.5 dB (nominal, 40 GHz < f ≤ 43 GHz)
 Measure function  Adjacent channel power (ACP), Channel power, Occupied bandwidth (OBW)
 Digitize function  Captured waveform data saved to internal HDD or output to external devices

 Hardware  MS2830A  Main frame
 MS2830A-044  26.5 GHz Signal Analyzer
 MS2830A-045  43 GHz Signal Analyzer
 MS2830A-001  Rubidium Reference Oscillator
 MS2830A-005  Analysis Bandwidth Extension to 31.25 MHz
 MS2830A-006  Analysis Bandwidth 10 MHz
 MS2830A-009  Bandwidth Extension to 31.25 MHz for Millimeter-wave
 (for MS2830A-045)
 MS2830A-077  Analysis Bandwidth Extension to 62.5 MHz
 MS2830A-078  Analysis Bandwidth Extension to 125 MHz
 MS2830A-008  Preamplifier
 MS2830A-010  Phase Noise Measurement Function
 MS2830A-011  2ndary HDD
 MS2830A-016  Precompliance EMI Function
 MS2830A-017  Noise Figure Measurement Function
 MS2830A-026  BER Measurement Function
 MS2830A-067  Microwave Preselector Bypass
 MS2830A-068  Microwave Preamplifier
 Software
 (Measurement software for Signal Analyzer)
 MX269011A  W-CDMA/HSPA Downlink Measurement Software
 MX269012A  W-CDMA/HSPA Uplink Measurement Software
 MX269013A  GSM/EDGE Measurement Software
 MX269013A-001  EDGE Evolution Measurement Software
 MX269015A  TD-SCDMA Measurement Software
 MX269017A  Vector Modulation Analysis Software
 MX269020A  LTE Downlink Measurement Software
 MX269020A-001  LTE-Advanced FDD Downlink Measurement Software
 MX269021A  LTE Uplink Measurement Software
 MX269022A  LTE TDD Downlink Measurement Software
 MX269022A-001  LTE-Advanced TDD Downlink Measurement Software
 MX269023A  LTE TDD Uplink Measurement Software
 MX269024A  CDMA2000 Forward Link Measurement Software
 MX269024A-001  All Measure Function   NEW
 MX269026A  EV-DO Forward Link Measurement Software
 MX269026A-001  All Measure Function   NEW
 MX269028A  WLAN (802.11) Measurement Software
 MX269028A-001  802.11ac (80 MHz) Measurement Software
 MX269030A  W-CDMA BS Measurement Software
 MX283027A  Wireless Network Device Test Software
 MX283027A-001  WLAN Test Software
 MX283027A-002  Bluetooth Test Software
 Warranty service MS2830A-ES210 2 years Extended Warranty Service